| Preface  | 
  
  
    | 
      Preface 
     | 
    
      Preface
     | 
  
  
    | Chapter 1 | 
  
  
    | 
       1
     | 
    
      Overview
     | 
  
  
    | 
           1.1
     | 
    
          Description
     | 
  
  
    | 
           1.2
     | 
    
          Device Communications
     | 
  
  
    | 
           1.3
     | 
    
          Supported Functions and Devices
     | 
  
  
    | Chapter 2 | 
  
  
    | 
       2
     | 
    
      Installing and Configuring the DAS
     | 
  
  
    | 
           2.1
     | 
    
          Installation Requirements
     | 
  
  
    | 
               2.1.1
     | 
    
              Hardware
     | 
  
  
    | 
               2.1.2
     | 
    
              Software
     | 
  
  
    | 
               2.1.3
     | 
    
              Disk Space
     | 
  
  
    | 
           2.2
     | 
    
          Installing the DAS
     | 
  
  
    | 
               2.2.1
     | 
    
              Files Created During Installation
     | 
  
  
    | 
               2.2.2
     | 
    
              Installation Messages
     | 
  
  
    | 
           2.3
     | 
    
          Postinstallation Tasks
     | 
  
  
    | 
               2.3.1
     | 
    
              Editing the Configuration Files
     | 
  
  
    | 
                   2.3.1.1
     | 
    
                  Editing ODS Registrations
     | 
  
  
    | 
                   2.3.1.2
     | 
    
                  Editing BASEstar Open Protocol Profile Definitions
     | 
  
  
    | 
                   2.3.1.3
     | 
    
                  Editing VMD Definitions
     | 
  
  
    | 
                   2.3.1.4
     | 
    
                  Configuration Files
     | 
  
  
    | 
               2.3.2
     | 
    
              Configuring Ports
     | 
  
  
    | 
               2.3.3
     | 
    
              Configuring TELNET Access
     | 
  
  
    | 
               2.3.4
     | 
    
              Setting Up Plant-Floor Equipment
     | 
  
  
    | 
           2.4
     | 
    
          Tracing device communications
     | 
  
  
    | 
           2.5
     | 
    
          Failures During Product Use
     | 
  
  
    | Chapter 3 | 
  
  
    | 
       3
     | 
    
      Using the DAS
     | 
  
  
    | 
           3.1
     | 
    
          Accessing Allen-Bradley Functions
     | 
  
  
    | 
           3.2
     | 
    
          Supported Functions
     | 
  
  
    | 
               3.2.1
     | 
    
              Connect, Conclude and Abort Functions
     | 
  
  
    | 
               3.2.2
     | 
    
              Read and Write Variable Functions
     | 
  
  
    | 
               3.2.3
     | 
    
              Read and Write Data Point Functions
     | 
  
  
    | 
               3.2.4
     | 
    
              Receiving Indications
     | 
  
  
    | 
                   3.2.4.1
     | 
    
                  Write Indications
     | 
  
  
    | 
                   3.2.4.2
     | 
    
                  Abort Indications
     | 
  
  
    | 
           3.3
     | 
    
          Addressing Syntax and Supported Data Types
     | 
  
  
    | 
               3.3.1
     | 
    
              PLC-2 Addressing Syntax and Supported Data Types
     | 
  
  
    | 
               3.3.2
     | 
    
              PLC-3 Addressing Syntax and Supported Data Types
     | 
  
  
    | 
                   3.3.2.1
     | 
    
                  PLC-3 Data Table Addressing
     | 
  
  
    | 
                   3.3.2.2
     | 
    
                  PLC-3 Extended Addressing
     | 
  
  
    | 
               3.3.3
     | 
    
              PLC-5 Addressing Syntax and Supported Data Types
     | 
  
  
    | 
               3.3.4
     | 
    
              PLC-5/250 Addressing Syntax and Supported Data Types
     | 
  
  
    | 
               3.3.5
     | 
    
              SLC Addressing Syntax and Supported Data Types
     | 
  
  
    | Appendix A | 
  
  
    | 
      Appendix A
     | 
    
      I/O Error Messages
     | 
  
  
    | Appendix B | 
  
  
    | 
      Appendix B
     | 
    
      DAS Error Messages
     | 
  
  
    | Index | 
  
    Index | 
  
  
    | Examples | 
  
  
    | 2-1 | 
    ODS Registration | 
  
  
    | 2-2 | 
    BASEstar Open Protocol Profile Configuration | 
  
  
    | 2-3 | 
    VMD Configuration | 
  
  
    | 2-4 | 
    ODS Configuration File | 
  
  
    | 2-5 | 
    BSTR Configuration File | 
  
  
    | 3-1 | 
    UNNAMED_VARIABLE CREATE Command | 
  
  
    | 3-2 | 
    UNNAMED_VARIABLE GET VALUE Output | 
  
  
    | 3-3 | 
    UNNAMED_VARIABLE PUT VALUE Output | 
  
  
    | 3-4 | 
    DEVICE_DATA_POINT CREATE Command | 
  
  
    | 3-5 | 
    DATA_POINT GET VALUE Output | 
  
  
    | 3-6 | 
    DATA_POINT PUT VALUE Output | 
  
  
    | 3-7 | 
    Write Indication Configuration | 
  
  
    | 3-8 | 
    AB.PAR Contents | 
  
  
    | 3-9 | 
    Write Indication Example | 
  
  
    | Figures | 
  
  
    | 1-1 | 
    DAS Communications | 
  
  
    | 2-1 | 
    Allen-Bradley 15 Pin Device Connector Layout | 
  
  
    | 2-2 | 
    Allen-Bradley 25 Pin Device Connector Layout | 
  
  
    | 2-3 | 
    Allen-Bradley 9 Pin Device Connector Layout | 
  
  
    | 3-1 | 
    General PLC-2 Address Format | 
  
  
    | 3-2 | 
    PLC-3 I/O Data Table Address Format | 
  
  
    | 3-3 | 
    PLC-3 Timer and Counter Data Table Address Format | 
  
  
    | 3-4 | 
    PLC-3 Timer Structure | 
  
  
    | 3-5 | 
    PLC-3 Counter Structure | 
  
  
    | 3-6 | 
    PLC-3 ASCII, Binary, Decimal, Floating-Point, High-Order Integer, Integer and Status Data Table Address Format | 
  
  
    | 3-7 | 
    PLC-3 Pointer Data Table Address Format | 
  
  
    | 3-8 | 
    PLC-3 Pointer Structure | 
  
  
    | 3-9 | 
    PLC-3 Extended Address Format | 
  
  
    | 3-10 | 
    PLC-5 I/O Data Table Address Format | 
  
  
    | 3-11 | 
    PLC-5 Status Data Table Address Format | 
  
  
    | 3-12 | 
    PLC-5 ASCII, Binary, Decimal, Floating-Point and Integer Data Table Address Format | 
  
  
    | 3-13 | 
    PLC-5 Timer, Counter, Control, SFC Status, Block-Transfer Control, Token Data, ASCII String, PID Control and Message Control  Data Table Address Format
 | 
  
  
    | 3-14 | 
    PLC-5 Timer Structure | 
  
  
    | 3-15 | 
    PLC-5 Counter Structure | 
  
  
    | 3-16 | 
    PLC-5 Control Structure | 
  
  
    | 3-17 | 
    PLC-5 SFC Status Structure | 
  
  
    | 3-18 | 
    PLC-5 Block-Transfer Control Structure | 
  
  
    | 3-19 | 
    PLC-5 Token Data Structure | 
  
  
    | 3-20 | 
    PLC-5 ASCII String Structure | 
  
  
    | 3-21 | 
    PLC-5 PID Control Structure | 
  
  
    | 3-22 | 
    PLC-5 Message Control Structure | 
  
  
    | 3-23 | 
    PLC-5 / 250 Binary, Floating-Point, Long Integer and Integer Address Format | 
  
  
    | 3-24 | 
    PLC-5 / 250 Timer, Counter, Control, ASCII String, PID Control and Message Control Address Format | 
  
  
    | 3-25 | 
    PLC-5 / 250 Timer Structure | 
  
  
    | 3-26 | 
    PLC-5 / 250 Counter Structure | 
  
  
    | 3-27 | 
    PLC-5 / 250 Control Structure | 
  
  
    | 3-28 | 
    PLC-5 / 250 ASCII String Structure | 
  
  
    | 3-29 | 
    PLC-5 / 250 PID Control Structure | 
  
  
    | 3-30 | 
    PLC-5 / 250 Message Control Structure | 
  
  
    | 3-31 | 
    PLC-5 / 250 Status Address Format | 
  
  
    | 3-32 | 
    PLC-5 / 250 I/O Address Format | 
  
  
    | 3-33 | 
    PLC-5 / 250 Block-Transfer Data Address Format | 
  
  
    | 3-34 | 
    PLC-5 / 250 Block-Transfer Read / Write Control Address Format | 
  
  
    | 3-35 | 
    PLC-5 / 250 Block-Transfer Read / Write Control Structure | 
  
  
    | 3-36 | 
    PLC-5 / 250 Adapter Status Address Format | 
  
  
    | 3-37 | 
    PLC-5 / 250 Adapter Status Structure | 
  
  
    | 3-38 | 
    PLC-5 / 250 Internal Storage Address Format | 
  
  
    | 3-39 | 
    PLC-5 / 250 Shared Data Address Format | 
  
  
    | 3-40 | 
    SLC I/O Data Table Address Format | 
  
  
    | 3-41 | 
    SLC Status Data Table Address Format | 
  
  
    | 3-42 | 
    SLC ASCII, Binary, Floating-Point and Integer Data Table Address Format | 
  
  
    | 3-43 | 
    SLC Timer, Counter, Control and ASCII String Data Table Address Format | 
  
  
    | 3-44 | 
    SLC Timer Structure | 
  
  
    | 3-45 | 
    SLC Counter Structure | 
  
  
    | 3-46 | 
    SLC Control Structure | 
  
  
    | 3-47 | 
    SLC ASCII String Structure | 
  
  
    | Tables | 
  
  
    | 2-1 | 
    Disk Space Requirements | 
  
  
    | 2-2 | 
    Files Created During Installation | 
  
  
    | 2-3 | 
    REGISTER Attributes | 
  
  
    | 2-4 | 
    VMD CREATE | 
  
  
    | 2-5 | 
    KE / KF / KF-2 / KF-3 Switch Settings | 
  
  
    | 3-1 | 
    Connect, Conclude and Abort Interface Access | 
  
  
    | 3-2 | 
    Read and Write Variable Types | 
  
  
    | 3-3 | 
    Read and Write Variable Interface Access | 
  
  
    | 3-4 | 
    Read and Write Data Point Interface Access | 
  
  
    | 3-5 | 
    Indication Interface Access | 
  
  
    | 3-6 | 
    Supported PLC Write Functions | 
  
  
    | 3-7 | 
    Example PLC-2 Data Types | 
  
  
    | 3-8 | 
    Example PLC-3 I/O Data Table Addresses | 
  
  
    | 3-9 | 
    Example PLC-3 Timer and Counter Data Table Addresses | 
  
  
    | 3-10 | 
    Example PLC-3 ASCII, Binary, Decimal, Floating-Point, High-Order Integer, Integer and Status Data Table Address Format | 
  
  
    | 3-11 | 
    Example PLC-3 Pointer Data Table Addresses | 
  
  
    | 3-12 | 
    Example PLC-3 Extended Addresses | 
  
  
    | 3-13 | 
    Example PLC-5 I/O Data Table Addresses | 
  
  
    | 3-14 | 
    Example PLC-5 Status Data Table Addresses | 
  
  
    | 3-15 | 
    Example PLC-5 ASCII, Binary, Decimal, Floating-Point and Integer Data Table Address Format | 
  
  
    | 3-16 | 
    Example PLC-5 Timer, Counter, Control, SFC Status, Block-Transfer Control, Token Data, ASCII String, PID Control and Message Control Data Table Address Formats
 | 
  
  
    | 3-17 | 
    Example PLC-5 / 250 Binary, Floating-Point, Long Integer and Integer Address Format | 
  
  
    | 3-18 | 
    Example PLC-5 / 250 Timer, Counter, Control, ASCII String, PID Control and Message Control Address Formats | 
  
  
    | 3-19 | 
    Example PLC-5 / 250 Status Addresses | 
  
  
    | 3-20 | 
    Example PLC-5 / 250 I/O Addresses | 
  
  
    | 3-21 | 
    Example PLC-5 / 250 Block-Transfer Data Addresses | 
  
  
    | 3-22 | 
    Example PLC-5 / 250 Block-Transfer Read / Write Control Addresses | 
  
  
    | 3-23 | 
    Example PLC-5 / 250 Adapter Status Addresses | 
  
  
    | 3-24 | 
    Example PLC-5 / 250 Internal Storage Addresses | 
  
  
    | 3-25 | 
    Example PLC-5 / 250 Shared Data Addresses | 
  
  
    | 3-26 | 
    Example SLC I/O Data Table Addresses | 
  
  
    | 3-27 | 
    Example SLC Status Data Table Addresses | 
  
  
    | 3-28 | 
    Example SLC ASCII, Binary, Floating-Point and Integer Data Table Address Format | 
  
  
    | 3-29 | 
    Example SLC Timer, Counter, Control and ASCII String Data Table Address Formats |