Previous | Contents | Index |
This chapter provides information about the supported functions for
Allen-Bradley devices, and how to access these functions.
3.1 Accessing DAS Functions
DAS for AB INTERCHANGE software functions are accessed through the following BASEstar Classic device connection management interfaces:
To access the BASEstar Classic device connection management CLI, enter the following command at the DCL prompt ($):
$ BSTAR DCM |
For information about BASEstar Classic device connection management commands, refer to the BASEstar Classic Command Line Interface User's Guide.
To access the BASEstar Classic device connection management menu interface, enter the following command:
$ BSTAR/MENU |
For additional information about the BASEstar Classic device connection management menu interface, refer to the BASEstar Classic Menu Interface User's Guide.
Application Programming Interface (API)
For information on accessing BASEstar Classic device connection management callable services, refer to the BASEstar Classic Introduction to Callable Services.
Not all device connection management functions are available through every interface. When a function is limited to a particular interface, it is described specifically in the description of the function. If a limitation is not specified, the function is available through all device connection management interfaces.
3.2 Supported Functions
Table 3-1 describes the functions supported by the DAS for AB INTERCHANGE software.
Devices | |||||
---|---|---|---|---|---|
Function | PLC 5/250 | PLC-5 Family | PLC-3 Family | PLC-2 Family | SLC Family |
Read Data | X | X | X | X | X |
Write Data | X | X | X | X | X |
Start | |||||
Stop | |||||
Upload | X 1 | ||||
Download | X 1 | ||||
Read Status | X | X | X | X | X |
Loop | X | X | X | X | X |
Delete File | |||||
Select File | |||||
Directory | |||||
Allocate---Deallocate | |||||
Device-Specific | |||||
Simple Compare | X 1 |
Previous | Next | Contents | Index |