Previous | Contents | Index |
The installation procedure provides a replacement for the ILAN startup file, ILAN$SYSTEM_STARTUP.TEMPLATE. The new file has been provided because the ILAN$DEVSRV image using the DAS for OMNI software needs additional quotas and privileges. The values used in the provided startup file are valid for a typical configuration and may be more or less than is actually required for your installation.
If quotas are not set properly, it is likely that the ILAN$DEVSRV process will ACCVIO or otherwise fail with very little diagnostic information provided. If you find that the ILAN$DEVSRV process is ACCVIOing soon after enabling devices or soon after startup, monitor the process using SHOW PROCESS/QUOTA/ID=XXXXXXXX to determine which quota the process is running low on. |
SYSGEN parameters may also need adjusting. Parameters which may need modifying include the following:
BASEstar Classic parameters may also need adjusting, depending on the number of devices configured. Parameters which may need modifying include the following:
See BASEstar Classic Configuration and Tuning Guide for details on changing BASEstar Classic parameters.
2.3.4 Defining OMNI Constants
A BASEstar Classic parameter is used to configure the maximum number of OMNI devices that can be created. This parameter is created as part of the DAS installation. To change the value of this parameter, change the value using the BASEstar Classic CLI. Then stop and restart BASEstar Classic to to enable the DAS to use the new parameter value. Table 2-8 lists the default and maximum value for this parameter.
Parameter | Default Value | Max Value |
---|---|---|
ILAN$OMNI_MAX_DEVICES | 64 | 500 |
The ILAN$MAX_SPT_REQUESTS parameter specifies the total number of blocks that can be allocated in the SPT (support) global section. DASes use blocks in the global section for storing data structures and for doing device I/O. The SPT global section is sized by calculating the number of SMALL, MEDIUM, LARGE and EXTRA LARGE blocks that the section should contain. Some blocks remain for the life of a device and some are allocated and deallocated for each I/O operation. Table 2-9 shows the static blocks of each size that are used by the DAS.
Block Size | Quantity1 | Block Type |
---|---|---|
MEDIUM | 2 | Device |
SMALL | 1 | Device 2 |
1 | Unsolicited point 2 | |
1 | DAS |
Table 2-10 shows the dynamic blocks of each size that are used by the DAS. These blocks are created and deleted as the device does I/O. The DAS also allocates and deallocates virtual memory to store control information when doing device I/O.
Block Size | Quantity1 | I/O Type |
---|---|---|
SMALL | 1 | Any |
The size of the SPT global section can be tuned by changing the
percentage of each kind of block that is created. Refer to the
BASEstar Classic Configuration and Tuning Guide for instructions on changing the percentage of each size
of block that is created in the global section.
2.3.6 Setting Up Shop Floor Equipment
To set up your shop floor equipment, see the documentation for your specific MMS, SINEC-S7, SINEC-AP or SINEC-H1 compliant device.
When configuring MMS devices be sure to note the PSAP, SSAP, TSAP and NSAP.
When configuring SINEC-S7, SINEC-AP or SINEC-H1 devices be sure to note the TSAP.