BASEstartm Classic DAS
for Siemens H1tm Protocol
Installation and User's Guide


Previous Contents Index

2.2 Installation

When your system meets all the hardware and software requirements, you can install the DAS for Siemens H1 Protocol. The installation takes from 1 to 5 minutes, depending on system load and configuration.

Install the DAS for Siemens H1 Protocol using the following steps:

  1. Log in to a privileged system manager's account.
  2. Set the default directory to SYS$UPDATE:


          $  SET DEFAULT SYS$UPDATE 
    

  3. Invoke VMSINSTAL:


          $  @SYS$UPDATE:VMSINSTAL DCM_H1VVA034 ddcu: 
    

    The DCM_H1VVA034 argument is the kit name. The 034 portion of the name is the version number. The ddcu argument represents the name of the device on which the installation media is mounted, where:

VMSINSTAL prompts you for information during the installation. Note that DECnet does not need to be running in order to perform the installation procedure. The following is an example of the output from the installation.


 
 
        OpenVMS VAX Software Product Installation Procedure V7.2 
 
 
It is 29-FEB-2000 at 14:16. 
 
Enter a question mark (?) at any time for help. 
 
* Are you satisfied with the backup of your system disk [YES]? 
 
The following products will be processed: 
 
  DCM_H1VVA V3.4
 
 
        Beginning installation of DCM_H1VVA V3.4 at 14:17 
 
%VMSINSTAL-I-RESTORE, Restoring product save set A ... 
%VMSINSTAL-I-RELMOVED, Product's release notes have been moved to SYS$HELP. 
 
   Copyright 1991 Compaq Computer Corporation 
 
   Confidential computer software.  Valid license from Compaq or authorized 
   sublicensor required for possession, use or copying.  Consistent with FAR 
   12.211 and 12.212, Commercial Computer Software, Computer Software 
   Documentation, and Technical Data for Commercial Items are licensed to the 
   U.S. Government under vendor's standard commercial license. 
 
   BASEstar Classic DAS for Siemens H1 Protocol installation procedure. 
 
   Checking for a valid license... 
 
 
 
        Product:      DAS-SH1-CL 
        Producer:     DEC 
        Version:      3.4 
        Release Date: 13-DEC-1996 
 
 
* Does this product have an authorization key registered and loaded? y 
 
   Now checking OpenVMS version... 
 
 
   Now checking that network software is installed... 
 
 
   Now checking that BASEstar Classic is installed... 
 
 
   Now checking disk space... 
 
* Do you want to purge files replaced by this installation [YES]? 
* Do you want to run the IVP after the installation [YES]? 
 
   The installation procedure has no further questions to ask and will 
   complete in 1 to 5 minutes depending on the system and system load. 
 
 
   The configuration template file for Siemens H1 support, 
   DCM_H1_CONFIG.TEMPLATE, is used to define the Siemens paths, types, 
   and devices.  Edit this file, as necessary, to reflect your specific 
   site configuration. 
 
   During installation it will be placed in the directory BCC$SYSDATA. 
 
%VMSINSTAL-I-SYSDIR, This product creates system directory [SYSHLP.EXAMPLES.DCM_ 
H1]. 
 
   The BASEstar Classic parameter ILAN$H1_TI_CR_BASE has just been created. 
 
 
Parameter ILAN$H1_TI_CR_BASE, type String. 
    Current value is "",  Default value is "". 
 
   The BASEstar Classic parameter ILAN$H1_TI_CR_SIZE has just been created. 
 
 
Parameter ILAN$H1_TI_CR_SIZE, type Value. 
    Current value is 1,  Default value is 1. 
    Minimum value is 1,  Maximum value is 10000. 
 
   The BASEstar Classic parameter ILAN$H1_TI_V_BASE has just been created. 
 
 
Parameter ILAN$H1_TI_V_BASE, type String. 
    Current value is "",  Default value is "". 
 
   The BASEstar Classic parameter ILAN$H1_TI_V_SIZE has just been created. 
 
 
Parameter ILAN$H1_TI_V_SIZE, type Value. 
    Current value is 1,  Default value is 1. 
    Minimum value is 1,  Maximum value is 10000. 
%VMSINSTAL-I-MOVEFILES, Files will now be moved to their target directories... 
 
   Copyright 1991 Compaq Computer Corporation 
 
   Confidential commercial computer software.  Valid license required. 
 
   Executing the Installation Verification Procedure. 
 
 
   BASEstar Classic DAS for Siemens H1 Protocol installation procedure 
   has succeeded. 
 
 
        Installation of DCM_H1VVA V3.4 completed at 14:18 
 
 
        VMSINSTAL procedure done at 14:18 
 
                                                                                

2.2.1 Files Created During Installation

Table 2-2 lists the files that the DAS for Siemens H1 Protocol installation procedure creates and the directories in which they are placed.

Table 2-2 Files Created During Installation
Directory Filename
BCC$SYSDATA: DCM_H1_CONFIG.TEMPLATE
   
SYS$LIBRARY: ILAN_SH1.EXE
  ILAN_VOTS.EXE
  DCM_H1$DEF.H
   
SYS$HELP: DCM_H1VVA034.RELEASE_NOTES (VAX)
  DCM_H1VAA034.RELEASE_NOTES (Alpha)
   
SYS$TEST: DCM_H1$IVP.COM
   
SYS$COMMON:[SYSHLP
.EXAMPLES.DCM_H1]
DCM_H1_SEND_EXAMPLE.C
  DCM_H1_RECEIVE_EXAMPLE.C

2.2.2 Installation Messages

You may see VMSINSTAL messages during the installation procedure. The following messages are specific to the DAS for Siemens H1 Protocol installation:

BADBCC, BASEstar Classic software must be installed before DAS for Siemens H1 Protocol.

Explanation: Error. Incorrect version of or missing BASEstar Classic software.
User Action: Install BASEstar Classic for OpenVMS, Release 3.4 or higher software.
BADDCM, BASEstar Classic Device Connect must be installed before the DAS for Siemens H1 Protocol.

Explanation: Error. Incorrect version of or missing BASEstar Classic DCM software.
User Action: Install BASEstar Classic DCM for OpenVMS, Release 3.4 or higher software.
BADDECNET, A valid version of DECnet must be installed before the DAS for Siemens H1 Protocol.

Explanation: Error. Incorrect version of DECnet Plus software.
User Action: Install DECnet Plus software Version 5.6B (VAX) or Version 5.7 (Alpha) or higher.
BADVMS (VAX), The DAS for Siemens H1 Protocol must be installed under OpenVMS V5.5-2 or greater.

Explanation: Error. Incorrect version of OpenVMS.
User Action: Install OpenVMS V5.5-2 or higher.
BADVMS (Alpha), The DAS for Siemens H1 Protocol must be installed under OpenVMS V6.1 or greater.

Explanation: Error. Incorrect version of OpenVMS.
User Action: Install OpenVMS V6.1 or higher.
NETBLOCKS (VAX), DAS for Siemens H1 Protocol requires 300 blocks after installation.

Explanation: Error. Not enough disk space to complete installation.
User Action: Delete any unnecessary files, then reinstall.
NETBLOCKS (Alpha), DAS for Siemens H1 Protocol requires 400 blocks after installation.

Explanation: Error. Not enough disk space to complete installation.
User Action: Delete any unnecessary files, then reinstall.
NOLICENSE, No license found for this product - IVP will not be run.,

Explanation: Informational. A valid license was not found. The installation will continue, but the IVP will not be run.
User Action: Register and load a valid license for this product before attempting to use the DAS.
NOLOAD, License for this product not loaded - IVP will not be run.,

Explanation: Informational. The license for this product has not been loaded by the License Management Utility. The installation willl proceed, but the IVP will not be run.
User Action: Load the license using the License Management Utility before attempting to use the DAS.


Previous Next Contents Index