The ILAN$MAX_SPT_REQUESTS parameter specifies the total number of blocks that can be allocated in the SPT (support) global section. DASes use blocks in the global section for storing data structures and for doing device I/O. The SPT global section is sized by calculating the number of SMALL, MEDIUM, LARGE and EXTRA LARGE blocks that the section should contain. Some blocks remain for the life of a device and some are allocated and deallocated for each I/O operation. Table 2-6 shows the static blocks of each size that are used by the DAS.
Block Size | Quantity1 | Block Type |
---|---|---|
MEDIUM | 2 | Device |
SMALL | 1 | Device 2 |
1 | Unsolicited point 2 |
Table 2-7 shows the dynamic blocks of each size that are used by the DAS. These blocks are created and deleted as the device does I/O.
Block Size | Quantity1 | I/O Type |
---|---|---|
LARGE | 1 | Upload/download |
1 | Read status | |
MEDIUM | 1 | Read/write 2 |
1 | Start/Stop 2 | |
1 | Send/Receive message | |
SMALL | 1 | Any |
The size of the SPT global section can be tuned by changing the
percentage of each kind of block that is created. Refer to the
BASEstar Classic Configuration and Tuning Guide for instructions on changing the percentage of each size
of block that is created in the global section.
2.3.4 Setting DAS-Specific Parameters
None of the parameters created for the DAS for Siemens H1 Protocol are dynamic. A device must be disabled and reenabled before the parameter modifications become effective.
The installation procedure for the DAS for Siemens H1 Protocol creates BASEstar Classic parameters to allow you to tune the DAS environment for accessing data in TI programmable controllers. These parameters are listed in Table 2-8.
Parameter | Description |
---|---|
ILAN$H1_TI_CR_BASE | This value specifies the starting block number for the control registers in the programmable controller. The value is specified as a "DB:XX" value. There is no default value for this parameter. |
ILAN$H1_TI_V_BASE | This value specifies the starting block number for the variable memory in the programmable controller. The value is specified as a "DB:XX" value. There is no default value for this parameter. |
ILAN$H1_TI_CR_SIZE | This value specifies the size of the DB block for control registers. The value is used to calculate which DB block to request when reading a CRXXXXX address. There is no default value for this parameter. |
ILAN$H1_TI_V_SIZE | This value specifies the size of the DB block for variable memory. The value is used to calculate which DB block to request when reading a VXXXXX address. There is no default value for this parameter. |
See Addressing Syntax for TI Devices for information on addressing for TI programmable
controllers and how TI addresses are translated into Siemens H1
addresses.
2.3.5 Setting Up Plant Floor Equipment
To set up your plant floor equipment, see the Siemens documentation for your specific device.