2.2.1 Files Created During Installation
Table 2_2 and Table 2-3 lists the files created by the
DAS for AB INTERCHANGE software installation procedure, and the directories in which
those files are placed for both the INTERCHANGE OpenVMS (Ethernet)
and PI MicroVAX options.
Table 2-2 DAS Files Created ( EI Network Interface Option)
Directory |
Filename |
BCC$SYSDATA:
|
DCM_DTL$MSG.DAT
|
|
DCM_DTL_CONFIG.TEMPLATE
|
|
DCM_DTL$SRV_STARTUP.COM
|
|
DCM_DTL$SRV_QUOTAS.DAT
|
|
|
BCC$SYSTEM:
|
DCM_DTL$SRV.EXE
|
|
DCM_DTL$EXPORT_6200.EXE
|
|
DCM_DTL$IMPORT_6200.EXE
|
|
DCM_DTL$SRV_STOP.EXE
|
|
|
SYS$HELP:
|
DCM_DTLVVA034.RELEASE_NOTES (VAX)
|
|
DCM_DTLVAA034.RELEASE_NOTES (Alpha)
|
|
|
SYS$LIBRARY:
|
ILAN_DTL.EXE
|
|
ILAN_DTLNET.EXE
|
|
ILAN_DTL_SCMP.EXE (VAX)
|
Table 2-3 DAS Files Created ( PI MicroVAX Option)
Directory |
Filename |
BCC$SYSDATA:
|
DCM_DTL$MSG.DAT
|
|
DCM_DTL_CONFIG.TEMPLATE
|
|
DCM_DTL$BPISRV_STARTUP.COM
|
|
DCM_DTL$SRV_QUOTAS.DAT
|
|
|
BCC$SYSTEM:
|
DCM_DTL$BPISRV.EXE
|
|
DCM_DTL$SRV_STOP.EXE
|
|
|
SYS$HELP:
|
DCM_DTLVVA034.RELEASE_NOTES (VAX)
|
|
DCM_DTLVAA034.RELEASE_NOTES (Alpha)
|
|
|
SYS$LIBRARY:
|
ILAN_DTL.EXE
|
|
ILAN_DTLBPI.EXE
|
|
|
SYS$MESSAGE:
|
DTL$MSG.EXE
|
Table 2-4 lists the files modified by the DAS for AB INTERCHANGE software
installation procedure, and the directories in which those files are
located.
2.2.2 Installation Messages
You may see VMSINSTAL messages during the installation procedure. The
following messages are specific to the DAS for AB INTERCHANGE software installation:
BADBCC, BASEstar Classic software must be installed before the
DAS for AB INTERCHANGE Software,
Explanation: Error. BASEstar Classic software must be
installed before installing the DAS for AB INTERCHANGE Software.
User Action: Install BASEstar Classic software,
Version 3.4.
BADDCM, BASEstar Classic Device Connect software must be installed
before the DAS for AB INTERCHANGE Software,
Explanation: Error. BASEstar Classic Device Connect
software must be installed before installing the DAS for AB INTERCHANGE Software.
User Action: Install BASEstar Classic Device Connect
Management software, Version 3.4.
BADVMS (Alpha), DAS for AB INTERCHANGE Software must be installed under OpenVMS
V6.1.,
Explanation: Error. The DAS is being installed on a
version of OpenVMS that is less than OpenVMS V6.1.
User Action: Upgrade OpenVMS to the required minimum
version and then install the DAS.
BADVMS (VAX), DAS for AB INTERCHANGE Software must be installed under OpenVMS
V5.5-2.,
Explanation: Error. The DAS is being installed on a
version of OpenVMS that is less than OpenVMS V5.5-2.
User Action: Upgrade OpenVMS to the required minimum
version and then install the DAS.
DTLBPI (VAX only), Installing MicroVAX version of the DAS...,
Explanation: Information. The INTERCHANGE Software for the PI MicroVAX version of
the DAS for AB INTERCHANGE software has been selected to be installed..
User Action: None. Continue with installation.
DTLNET, Installing Ethernet version of the DAS...,
Explanation: Information. The INTERCHANGE Software for OpenVMS version of
the DAS for AB INTERCHANGE software has been selected to be installed..
User Action: None. Continue with installation.
NETBLOCKS (VAX), The DAS for AB INTERCHANGE Software requires 500 blocks after
installation,
Explanation: Error. There is not enough disk space
available to install DAS for AB INTERCHANGE software.
User Action: Free up sufficient disk space to complete
the installation.
NETBLOCKS (Alpha), The DAS for AB INTERCHANGE Software requires 1000 blocks
after installation,
Explanation: Error. There is not enough disk space
available to install DAS for AB INTERCHANGE software.
User Action: Free up sufficient disk space to complete
the installation.
NODTLNET, Allen-Bradley INTERCHANGE software must be installed before
the DAS for AB INTERCHANGE Software,
Explanation: Error. Correct version of INTERCHANGE Software for OpenVMS
must be installed before the DAS for AB INTERCHANGE software.
User Action: Install INTERCHANGE Software for OpenVMS.
NODTLPI, Allen-Bradley INTERCHANGE software must be installed before
the DAS for AB INTERCHANGE Software,
Explanation: Error. Correct version of INTERCHANGE Software for the PI MicroVAX
must be installed before DAS for AB INTERCHANGE software.
User Action: Install INTERCHANGE Software for the PI MicroVAX.
NOLICENSE, No license found for this product - IVP will not be run.,
Explanation: Informational. A valid license was not
found. The installation will continue, but the IVP will not be run.
User Action: Register and load a valid license for
this product before attempting to use the DAS.
NOLOAD, License for this product not loaded - IVP will not be run.,
Explanation: Informational. The license for this
product has not been loaded by the License Management Utility. The
installation willl proceed, but the IVP will not be run.
User Action: Load the license using the License
Management Utility before attempting to use the DAS.