BASEstartm Classic DAS
for Allen-Bradley
INTERCHANGEtm Software
Installation and User's Guide


Previous Contents Index

3.2.4 Loop Diagnostic Function

The loop function sends a diagnostic loop-back message and waits for a response. The source of the response depends upon the extent of the diagnostic message as determined by the LOOP command qualifier or the loop_flag argument to the device connection management callable service. Table 3-10 describes the path of the diagnostic message according to the specified parameter.
Parameter Response
/PE
ILAN$K_LOOP_PE
Elapsed time
/NI
ILAN$K_LOOP_NI
Elapsed time

The Loop PE function sends a message to the PE and a response is returned by the PE.

The Loop NI function is routed through the NI to the DTL server process. The server process returns the message back through the NI. The Loop NI function is a good method of determining the availability of the DTL server process.

Table 3-10 describes how to access the loop diagnostic function through the BASEstar Classic interfaces.

Table 3-10 Loop Interface Access
Interface Function Name
CLI LOOP
API ILAN$LOOP_DEVICE
  ILAN$LOOP_DEVICE_A
Menu Not available

Example 3-9 shows the information displayed by the LOOP command.

Example 3-9 Loop Output

DCM> LOOP DTL5/PE
 ELAPSED:    0 00:00:00.04  CPU: 0:00:00.03  BUFIO: 0  DIRIO: 0  FAULTS: 0 
 
DCM> LOOP DTL5/NI
 ELAPSED:    0 00:00:00.11  CPU: 0:00:00.02  BUFIO: 0  DIRIO: 0  FAULTS: 0 
 

3.2.5 Simple Compare Function

The simple compare function allows a BASEstar Classic library file related to a device to be compared to another existing BASEstar Classic library file of the same type. The BASEstar Classic library file must have been uploaded into the library directly or imported by the appropriate library function.

Simple compare is only supported by the EI Network Interface option of the DAS. Only PLC-5 family memory images (not including the PLC-5/250) may be compared.

Table 3-11 describes how to access the simple compare function through the BASEstar Classic interfaces.

Table 3-11 Simple Compare Interface Access
Interface Function Name
CLI Not available
API Not available
Menu Library File Compare File
Menu Library External Compare Device

The default compare behavior for DAS for AB INTERCHANGE software is controlled by the BASEstar Classic parameter ILAN$DTL_SCMP_FLAGS. The values and defaults for these compare qualifiers are described in Table 3-12.

Table 3-12 Simple Compare Qualifiers
Qualifier Default Description
ALL   All compare options are checked
[NO]TYPE TYPE Memory images must be of the same PLC type
[NO]REVISION NOREVISION Memory images must be of the same PLC type, series and revision
[NO]MEMSIZE MEMSIZE Memory images must have the same memory size
[NO]NUMTABLES NUMTABLES Memory images must have the same number of data table files.
[NO]NUMPROGRAMS NUMPROGRAMS Memory images must have the same number of program files.
[NO]DATATABLES NODATATABLES Compare the data tables
[NO]FORCES FORCES Compare the forces
[NO]DIRECTORY DIRECTORY Compare program directories
[NO]LADDER LADDER Compare the ladder logic.


Previous Next Contents Index