/ALIGN[=(option[,...])]
Prints alignment pages to aid in aligning printer forms. Use this
qualifier only when restarting an output execution queue from a paused
state.
After the alignment is complete, the queue enters a paused state until
you restart it by reentering the START/QUEUE command. Printing resumes
from the point where alignment data started; that is, the task is
backspaced over the pages printed for alignment.
Possible options are as follows:
MASK
|
Specifies that input data is masked by replacing alphabetic characters
with x's and numbers with 9s; nonalphanumeric characters are not
masked. Mask characters allow you to prevent the printing of sensitive
information. If you omit the MASK option, data is printed unaltered.
|
n
|
Specifies the number of alignment pages to print. The value of
n can be from 1 to 20. By default, one page of alignment data
is printed.
|
/AUTOSTART_ON=(node::[device][,...])
Designates the queue as an autostart execution queue and specifies the
node, or node and device, on which the queue can be located. Both
node and device must be specified for output queues.
For batch queues, only node is applicable.
In an OpenVMS Cluster, you can specify more than one node (or node and
device) on which a queue can run, in the preferred order in which nodes
should claim the queue. This allows the queue to fail over to another
node if the node on which the queue is running leaves the cluster.
For autostart queues, the START/QUEUE command activates the queue for
autostart. The queue will begin processing jobs when the ENABLE
AUTOSTART/QUEUES command is entered for a node on which the queue can
run.
This qualifier cannot be used with the /ON or /GENERIC qualifier;
however, you can specify the /AUTOSTART_ON qualifier for a queue
previously created or started with the /ON qualifier. Doing so
overrides the /ON option and makes the queue an autostart queue.
For more information about autostart queues, see the chapter about
managing queues in the HP OpenVMS System Manager's Manual.
/BACKWARD=n
Restarts a print queue n pages before the current page;
n defaults to 1. If you omit the page value, printing resumes
at the top of the current page. Use this qualifier only when restarting
an output execution queue from a paused state.
Note
Using the START/QUEUE/BACKWARD=n command to restart a print
job that uses Fortran carriage control and that was printed with the
/NOFEED qualifier can have unexpected results, in particular:
- The page positioning in the restarted job may not be correct: the
output may not begin at the top of the page specified by n.
- The output from the print job may be preceded by extra meaningless
information.
|
/BASE_PRIORITY=n
Specifies the base process priority at which jobs are initiated from a
batch execution queue. By default, if you omit the qualifier, jobs are
initiated at the same priority as the base priority established by
DEFPRI at system generation (usually 4). The base priority specifier
can be any decimal value from 0 to 15.
/BLOCK_LIMIT=([lowlim,]uplim)
/NOBLOCK_LIMIT
Limits the size of print jobs that can be processed on an output
execution queue. This qualifier allows you to reserve certain printers
for certain size jobs. You must specify at least one of the parameters.
The lowlim parameter is a decimal number referring to the
minimum number of blocks that are accepted by the queue for a print
job. If a print job is submitted that contains fewer blocks than the
the lowlim value, the job remains pending until the block
limit for the queue is changed. After the block limit for the queue is
decreased sufficiently, the job is processed.
The uplim parameter is a decimal number referring to the
maximum number of blocks that are accepted by the queue for a print
job. If a print job is submitted that exceeds this value, the job
remains pending until the block limit for the queue is changed. After
the block limit for the queue is increased sufficiently, the job is
processed.
If you specify only an upper limit for jobs, you can omit the
parentheses. For example, /BLOCK_LIMIT=1000 means that only jobs with
1000 blocks or less are processed in the queue. To specify only a lower
job limit, you must use a null string ("") to indicate the upper
specifier. For example, /BLOCK_LIMIT=(500,"") means any job with 500 or
more blocks is processed in the queue. You can specify both a lower and
upper limit. For example, /BLOCK_LIMIT=(200,2000) means that jobs with
less than 200 blocks or more than 2000 blocks are not processed in the
queue.
The /NOBLOCK_LIMIT qualifier cancels the previous setting established
by the /BLOCK_LIMIT qualifier for the queue.
/CHARACTERISTICS=(characteristic[,...])
/NOCHARACTERISTICS
Specifies one or more characteristics for processing jobs on an
execution queue. If a queue does not have all the characteristics that
have been specified for a job, the job remains pending. If you specify
only one characteristic, you can omit the parentheses. Each time you
specify the /CHARACTERISTICS qualifier, all previously set
characteristics are canceled. Only the characteristics specified with
the qualifier are established for the queue.
Queue characteristics are installation specific. The characteristic
parameter can be either a value from 0 to 127 or a characteristic name
that has been defined by the DEFINE/CHARACTERISTIC command.
The /NOCHARACTERISTICS qualifier cancels any settings previously
established by the /CHARACTERISTICS qualifier for the queue.
/CLOSE
Prevents jobs from being entered in the queue through PRINT or SUBMIT
commands or as a result of requeue operations. To allow jobs to be
entered, use the /OPEN qualifier. Whether a queue accepts or rejects
new job entries is independent of the queue's state (such as paused,
stopped, or stalled). When a queue is marked closed, jobs executing
continue to execute. Jobs already pending in the queue continue to be
candidates for execution.
/CPUDEFAULT=time
Defines the default CPU time limit for jobs in this batch execution
queue. You can specify time as delta time, 0, INFINITE, or NONE. You
can specify up to 497 days of delta time.
If the queue does not have a specified CPUMAXIMUM time limit and the
value established in the user authorization file (UAF) has a specified
CPU time limit of NONE, either the value 0 or the keyword INFINITE
allows unlimited CPU time. If you specify NONE, the CPU time value
defaults to the value specified either in the UAF or by the SUBMIT
command (if included). CPU time values must be greater than or equal to
the number specified by the system parameter PQL_MCPULM.
For information on specifying delta times, see the OpenVMS User's Manual or the
online help topic Date. For more information on specifying CPU time
limits, see the CPU Time Limit Specifications and Actions table for the
INITIALIZE/QUEUE command.
/CPUMAXIMUM=time
Defines the default CPU time limit for all jobs in this batch execution
queue. You can specify time as delta time, 0, INFINITE, or NONE. You
can specify up to 497 days of delta time.
If the queue does not have a specified CPUMAXIMUM time limit and the
value established in the UAF has a specified CPU time limit of NONE,
either the value 0 or the keyword INFINITE allows unlimited CPU time.
If you specify NONE, the CPU time value defaults to the value specified
either in the UAF or by the SUBMIT command (if included). CPU time
values must be greater than or equal to the number specified by the
system parameter PQL_MCPULM. The time cannot exceed the CPU time limit
set by the /CPUMAXIMUM qualifier. For information on specifying delta
time, see the OpenVMS User's Manual or the online help topic Date. For more
information on specifying CPU time limits, see the CPU Time Limit
Specifications and Actions table for the INITIALIZE/QUEUE command.
/DEFAULT=(option[,...])
/NODEFAULT
Establishes defaults for certain options of the PRINT command. Defaults
are specified by the list of options. If you specify only one option,
you can omit the parentheses. After you set an option for the queue
with the /DEFAULT qualifier, you do not have to specify that option in
your PRINT commands. If you do specify these options in your PRINT
command, the values specified with the PRINT command override the
values established for the queue with the /DEFAULT qualifier.
You cannot use the /DEFAULT qualifier with the /GENERIC qualifier.
Possible options are as follows:
[NO]BURST[=keyword]
|
Controls whether two file flag pages with a burst bar between them are
printed preceding output. If you specify the value ALL (default), these
flag pages are printed before each file in the job. If you specify the
value ONE, these flag pages are printed once before the first file in
the job.
|
[NO]FEED
|
Specifies whether a form feed is inserted automatically at the end of a
page.
|
[NO]FLAG[=keyword]
|
Controls whether a file flag page is printed preceding output. If you
specify the value ALL (default), a flag page is printed before each
file in the job. If you specify the value ONE, a flag page is printed
once before the first file in the job.
|
FORM=type
|
Specifies the default form for an output execution queue. If a job is
submitted without an explicit form definition, this form is used to
process the job. If no form type is explicitly specified with the FORM
keyword, the system assigns the form "DEFAULT" to the queue.
See also the description of the /FORM_MOUNTED qualifier.
|
[NO]TRAILER[=keyword]
|
Controls whether a file trailer page is printed following output. If
you specify the value ALL (default), a trailer page is printed after
each file in the job. If you specify the value ONE, a trailer page is
printed once after the last file in the job.
|
When you specify the BURST option for a file, the [NO]FLAG option does
not add or subtract a flag page from the two flag pages that are
printed preceding the file. For information on establishing mandatory
queue options, see the description of the /SEPARATE qualifier. For more
information on specifying default queue options, see the HP OpenVMS System Manager's Manual.
/DESCRIPTION=string
/NODESCRIPTION
Specifies a string of up to 255 characters that is used to provide
operator-supplied information about the queue.
Enclose strings containing lowercase letters, blanks, or other
nonalphanumeric characters (including spaces) in quotation marks
(" ").
The /NODESCRIPTION qualifier removes any descriptive text that may be
associated with the queue.
/DISABLE_SWAPPING
/NODISABLE_SWAPPING
Controls whether batch jobs executed from a queue can be swapped in and
out of memory.
/ENABLE_GENERIC
/NOENABLE_GENERIC
Specifies whether files queued to a generic queue that does not specify
explicit queue names with the /GENERIC qualifier can be placed in this
execution queue for processing. For more information, see the
description of the /GENERIC qualifier.
/FORM_MOUNTED=type
Specifies the mounted form for an output execution queue.
If no form type is explicitly specified, the system assigns the form
"DEFAULT" to the queue.
If the stock of the mounted form does not match the stock of the
default form, as indicated by the /DEFAULT=FORM qualifier, all jobs
submitted to this queue without an explicit form definition enter a
pending state and remain pending until the stock of the mounted form of
the queue is identical to the stock of the form associated with the job.
If a job is submitted with an explicit form and the stock of the
explicit form is not identical to the stock of the mounted form, the
job enters a pending state and remains pending until the stock of the
mounted form of the queue is identical to the stock of the form
associated with the job.
To specify the form type, use either a numeric value or a form name
that has been defined by the DEFINE/FORM command. Form types are
installation-specific. You cannot use the /FORM_MOUNTED qualifier with
the /GENERIC qualifier.
/FORWARD=n
Advances the specified number of pages before resuming printing the
current file in the current job; the default is 1. If you omit the page
value, printing resumes at the top of the next page. Use this qualifier
only when restarting an output execution queue from a paused state.
/GENERIC[=(queue-name[,...])]
/NOGENERIC
Specifies a generic queue. Also specifies that jobs placed in this
queue can be moved for processing to compatible execution queues. The
/GENERIC qualifier optionally accepts a list of target execution queues
that have been previously defined. For a generic batch queue, these
target queues must be batch execution queues. For a generic output
queue, these target queues must be output execution queues, but can be
of any type (printer, server, or terminal). For example, a generic
printer queue can feed a mixture of printer and terminal execution
queues.
Use the /GENERIC qualifier to change the list of target nodes for a
generic queue. The queue must have been initialized as a generic queue
with the INITIALIZE/QUEUE/GENERIC command.
If you do not specify any target execution queues with the /GENERIC
qualifier, jobs can be moved to any execution queue that (1) is
initialized with the /ENABLE_GENERIC qualifier, and (2) is the same
type (batch or output) as the generic queue.
To define the queue as a generic batch or output queue, you use the
/GENERIC qualifier with either the /BATCH or the /DEVICE qualifier. If
you specify neither the /BATCH nor the /DEVICE qualifier on creation of
a generic queue, by default the queue becomes a generic printer queue.
/JOB_LIMIT=n
Specifies the number of batch jobs that can be executed concurrently
from the queue. Specify a number in the range 0 to 255.
/LIBRARY=filename
/NOLIBRARY
Specifies the file name for the device control library. When you
initialize an output execution queue, you can use the /LIBRARY
qualifier to specify an alternate device control library. You can use
only a file name as the parameter of the /LIBRARY qualifier. The system
always assumes that the file is located in SYS$LIBRARY and that the
file type is .TLB.
/NEXT
Aborts the currently suspended print job and begins processing of the
first pending job in the queue. Use this qualifier only when restarting
an output execution queue from a paused state.
/NO_INITIAL_FF
/NONO_INITIAL_FF (default)
Specifies whether a form feed should be sent to a printer device when a
queue starts. To suppress the initial form feed, use the /NO_INITIAL_FF
qualifier.
The /NONO_INITIAL_FF qualifier sends a form feed to the output device
to ensure that the paper is at the top of a page before printing begins.
/ON=[node::]device[:] (printer, terminal, server queue)
/ON=node:: (batch queue)
Specifies the node or device, or both, on which this execution queue is
located. For batch execution queues, you can specify only the node
name. For output execution queues, you can include both the node name
and the device name.
The node name is used only in VAXcluster systems; it must match the
node name specified by the system parameter SCSNODE for the VAX
computer on which the queue executes.
You cannot use the /ON qualifier with the /AUTOSTART_ON or /GENERIC
qualifier; however, you can specify the /ON qualifier for a queue
previously created or started with the /AUTOSTART_ON qualifier. Doing
so overrides the /AUTOSTART_ON qualifier and makes the queue a
nonautostart queue.
/OPEN
Allows jobs to be entered in the queue through PRINT or SUBMIT commands
or as the result of requeue operations. To prevent jobs from being
entered in the queue, use the /CLOSE qualifier. Whether a queue accepts
or rejects new job entries is independent of the queue's state (such as
paused, stopped, or stalled).
/OWNER_UIC=uic
Requires manage (M) access to the queue.
Enables you to change the user identification code (UIC) of the queue.
Specify the UIC by using standard format as described in the
OpenVMS User's Manual.
/PROCESSOR=filename
/NOPROCESSOR
Requires OPER (operator) privilege to change the file name from
the one with which the queue was initialized.
Allows you to specify your own print symbiont for an output execution
queue. You can use any valid file name as a parameter of the /PROCESSOR
qualifier. The system supplies the device and directory name SYS$SYSTEM
and the file type .EXE. If you use this qualifier for an output queue,
it specifies that the symbiont image to be executed is
SYS$SYSTEM:filename.EXE.
By default, SYS$SYSTEM:PRTSMB.EXE is the symbiont image associated with
an output execution queue.
The /NOPROCESSOR qualifier cancels any previous setting established by
the /PROCESSOR qualifier, and causes SYS$SYSTEM:PRTSMB.EXE to be used.
/PROTECTION=(ownership[:access],...)
Requires OPER (operator) privilege, or control (C) and execute
(E) access to the queue.
Specifies the protection of the queue.
- Specify the ownership parameter as system (S), owner (O),
group (G), or world (W).
- Specify the access parameter as read (R), submit (S),
manage (M), or delete (D). A null access specification means no access.
If you include only one protection code, you can omit the parentheses.
For more information on specifying protection codes, see the
HP OpenVMS Guide to System Security. For more information on controlling queue operations
through UIC-based protection, see the HP OpenVMS System Manager's Manual.
/RAD=n (Alpha/I64 only)
Specifies the RAD number on which to run batch jobs assigned to the
queue. The RAD value is validated as a positive integer between 0 and
the value returned by the $GETSYI item code, SYI$_RAD_MAX_RADS.
Supported only on AlphaServer GS series systems.
/RECORD_BLOCKING
/NORECORD_BLOCKING
Determines whether the symbiont can concatenate (or block together)
output records for transmission to the output device. If you specify
the /NORECORD_BLOCKING qualifier, the symbiont sends each formatted
record in a separate I/O request to the output device. For the standard
OpenVMS print symbiont, record blocking can have a significant
performance advantage over single-record mode.
/RETAIN[=option]
/NORETAIN
Holds jobs in the queue in a retained status after they have executed.
The /NORETAIN qualifier enables you to reset the queue to the default.
Possible options are as follows:
ALL
|
Holds all jobs in the queue after execution.
|
ERROR
|
Holds in the queue only jobs that fail to complete.
|
A user can request a job retention option for a job by specifying the
/RETAIN qualifier with the PRINT, SUBMIT, or SET ENTRY command.
However, the job retention option you specify for a queue overrides any
job retention option requested by a user for a job in that queue.
/SCHEDULE=[NO]SIZE
Specifies whether pending jobs in an output queue are scheduled for
printing based on the size of the job. When the /SCHEDULE=SIZE
qualifier is in effect, shorter jobs are printed before longer ones.
When the /SCHEDULE=NOSIZE qualifier is in effect, jobs are printed in
the order they were submitted, regardless of size.
If you enter this command while there are pending jobs in any queue,
its effect on future jobs is unpredictable.
/SEARCH="search-string"
Specifies that printing is to resume at the page containing the
specified string. The search for the string moves forward, beginning on
the page following the current page. During the search, consecutive
tabs and spaces are treated as a single space, and character case is
ignored. The string can be from 1 to 63 characters and must be enclosed
in quotation marks (" "). Use this qualifier only when
restarting an output execution queue from a paused state.
/SEPARATE=(option[,...])
/NOSEPARATE
Specifies the mandatory queue options, or job separation options, for
an output execution queue. Job separation options cannot be overridden
by the PRINT command.
You cannot use the /SEPARATE qualifier with the /GENERIC qualifier.
The job separation options are as follows:
[NO]BURST
|
Specifies whether two job flag pages with a burst bar between them are
printed at the beginning of each job.
|
[NO]FLAG
|
Specifies whether a job flag page is printed at the beginning of each
job.
|
[NO]TRAILER
|
Specifies whether a job trailer page is printed at the end of each job.
|
[NO]RESET=(module[,...])
|
Specifies one or more device control library modules that contain the
job reset sequence for the queue. The specified modules from the
queue's device control library (by default SYS$LIBRARY:SYSDEVCTL) are
used to reset the device each time a job reset occurs. The RESET
sequence occurs after any file trailer and before any job trailer.
Thus, all job separation pages are printed when the device is in its
RESET state.
|
When you specify /SEPARATE=BURST, the [NO]FLAG separation option does
not add or subtract a flag page from the two flag pages that are
printed preceding the job.
For information on establishing queue options that can be overridden,
see the description of the /DEFAULT qualifier.
For more information on specifying mandatory queue options, see the
HP OpenVMS System Manager's Manual.
/TOP_OF_FILE
Resumes printing at the beginning of the file that was current when the
output execution queue paused. Use this qualifier only when restarting
an output execution queue from a paused state.
/WSDEFAULT=n
Defines for a batch job a working set default, the default number of
physical pages that the job can use. The value set by this qualifier
overrides the value defined in the user authorization file (UAF) of any
user submitting a job to the queue.
You also can specify this qualifier for an output execution queue. Used
in this context, the /WSDEFAULT qualifier establishes the working set
default of the symbiont process for an execution queue when the
symbiont process is created.
Specify the value of n as a number of 512-byte pagelets on
Alpha or 512-byte pages on VAX. Note that the operating systems rounds
up this value to the nearest CPU-specific page so that the actual
amount of physical memory allowed may be larger than the specified
amount on Alpha.
If you specify the value 0 or NONE, the working set default value
defaults to the value specified in the UAF or by the SUBMIT command (if
included).
For more information about the way a working set default affects batch
jobs, see Table DCLII-22.
/WSEXTENT=n
Defines for the batch job a working set extent, the maximum amount of
physical memory that the job can use. The job uses the maximum amount
of physical memory only when the system has excess free pages. The
value set by this qualifier overrides the value defined in the user
authorization file (UAF) of any user submitting a job to the queue.
You also can specify this qualifier for an output execution queue. Used
in this context, the /WSEXTENT qualifier establishes the working set
extent of the symbiont process for an output execution queue when the
symbiont process is created.
Specify the value of n as a number of 512-byte pagelets on
Alpha or 512-byte pages on VAX. Note that the operating system rounds
up this value to the nearest CPU-specific page so that the actual
amount of physical memory allowed may be larger than the specified
amount on Alpha.
If you specify the value 0 or NONE, the working set extent value
defaults to the value specified in the UAF or by the SUBMIT command (if
included).
For more information about the way a working set extent affects batch
jobs, see Table DCLII-22.
/WSQUOTA=n
Defines for a batch job a working set quota, the amount of physical
memory that is guaranteed to the job. The value set by this qualifier
overrides the value defined in the user authorization file (UAF) of any
user submitting a job to the queue.
You also can specify this qualifier for an output execution queue. Used
in this context, the /WSQUOTA qualifier establishes the working set
quota of the symbiont process for an output execution queue when the
symbiont process is created.
Specify the value of n as a number of 512-byte pagelets on
Alpha or 512-byte pages on VAX. Note that the operating system rounds
up this value to the nearest CPU-specific page so that the actual
amount of physical memory allowed may be larger than the specified
amount on Alpha.
If you specify the value 0 or NONE, the working set quota value
defaults to the value specified in the UAF or by the SUBMIT command (if
included).
Working set default, working set quota, and working set extent values
are included in each user record in the system UAF. You can specify
working set values for individual jobs or for all jobs in a given
queue. The decision table (Table DCLII-22) shows the action taken for
different combinations of specifications that involve working set size
and working set quota values.