Summary: Micropolis 1991 9gb - DU 4.0B

From: <david.buxton_at_bbsrc.ac.uk>
Date: Tue, 2 Sep 97 11:11:00 +0100

A summary follows with regards to the problems I was having with a
Micropolis 1991 9Gb when used with Digital UNIX 4.0B

The problem has been tracked down to a power saving function on Dec Unix 4.0b
that allows the spin down of devices to save energy.

With the help of the dxpower GUI I was able to find an option to prevent
the drives from spining down. The errors have now gone and I no longer need
to run my cron script to provide regular access to the drive.

another useful command to see if the system has power management configured
is :-

sysconfig -q pwrmgr


Special Thanks to :-

Sean O'Connell

Who has solved my problem

Many thanks to everyone else who provided useful infomation and suggestions.

Regards
David Buxton

-------------------------------------------------------------------------
David.Buxton_at_bbsrc.ac.uk BITS, West Common,
                                Harpenden, Herts. AL5 2JE