Hello,
I have 2 HSZ40's configured in dual redundant and I'm running V2.7 software.
I have a couple of easy questions.
1st question:
"I'm trying to run the cfmenu program via the hszterm utility. It doesn't
work. I read the man page of hszterm and I set and exported the HSZTERM_RUN
variable before running hszterm. Once in hszterm, whenever I try the 'RUN
CFMENU' command, I receive an 'Illegal RUN Command' error message". Also,
which LUN am I supposed to use when I call the hszterm program ? Should I
use the LUN of a configured device or should I use the LUN of the controler
itself ?
2nd question:
Whenever I 'warm swap' a device from one of the BA356's connected to the
HSZ40, after device removal, waiting 1-2 minutes, and device re-insertion, I
get the following message after each command I issue at the controler's
console (or through hszterm). I receive that message even if I only press
RETURN.
SWAP signal cleared - all swap interrupts re-enabled.
The only way I found of getting ride of this message (which by the way I
don't undertand at all (like most HSZ40 messages)) was to run CFMENU and
exit. After CFMENU is run, the messages disapear. There must be a better way
(other than using Microsoft's stuff :-) )
Thanks !
Guy Dallaire
dallaire_at_total.net
"God only knows if god exists"
Received on Thu Jan 23 1997 - 00:37:46 NZDT