SUMMARY: Replacing failed drive in SWXCR RAID-5 set

From: Lance A. Brown <brown9_at_niehs.nih.gov>
Date: Tue, 06 Jan 1998 17:27:22 -0500

The problem turned out to be that we had mistakenly replaced the
failed RZ28 drive with an RZ29. The online swxcrmgr refused to
recognize the RC29 as a new drive. When we put a fresh RZ28 in
everything worked as advertised.


--[Lance Brown]
     OAO ITSS SysAdmin Task at the NIEHS


My original message:

> I've got an alpha 2100 with a DAC960 RAID card in it. The 4-disk RAID
> 5 diskset has a failed drive that is giving me problems.

> I had the failed drive removed and replaced with a new, fresh unit
> and then started swxrmgr (v1.1.1) under X. Selecting Management->
> Make Optimal results in an error box telling me 'No device can be
> selected for the current drive array operation'.

> After replacing the failed drive clicking on the FLD drive box it give
> me a 'A device is configured but not physically present at this
> location' message.

> What am I doing wrong?

> Am I going to have to take the system down to make the RAID controller
> let me rebuild the RAID-5 set properly?
Received on Tue Jan 06 1998 - 23:27:41 NZDT