Disc i/o error on Alpha au500

From: Gunnar Petersson <Gunnar.Petersson_at_crabix.mep.ki.se>
Date: Fri, 09 Jan 1998 14:36:12 +0100

Hello,

This is my first posting on this list so be patient, please.

Problem: I/O errors on several discs now and then, slow performance on disc
                 operations

Spec: Digital Alpha au500, 768 mb internal memory, 2 extra wide-scsi
     adapterboards,10 external Fujitsu discs, 1 internal Digital system-disk
      Digital Unix 4.0C

The i/o errors has happend on several disk, sometimes so severe that the
computer crashes, sometimes easy fixed with rebooting, sometimes corrupt
file structure but mostly just to work on after rebooting. As said this
happens on several disk and on different scsi-boards. I/O errors sometimes
only on part of the disk, as an example you can work at the root but if you
cd down the structure you get i/o error. Also slow operation on commands
like cd and ls after approx. 30 min after reboot, yes, exactly after
rebooting there seems to be no perfomance problems.

Digital Sweden has tried to solve this but at no result. Their test
programs just works fine. Their solution = by Digital discs.

The discs worked fine earlier with an Alpha 433.

Anyone that has any suggestions? Feel free to ask for more info, i'm not to
familiar with Alpha and Unix (more VMS/NT system management).

Yours Sincerely,

/Gunnar Petersson
----------------------------------------
Gunnar Petersson
Institutionen för medicinsk epidemiologi
Department of Medical Epidemiology
Karolinska Institutet
Box 281
S-171 77 Stockholm
Tel: +46 8 728 61 82
Fax: +46 8 31 49 75
e-mail: Gunnar.Petersson_at_mep.ki.se
-----------------------------------------
Received on Fri Jan 09 1998 - 14:33:14 NZDT