UPDATE ON SUMMARY: Upgrade to 4.0D with system disk on Intraserver controller ...

From: Thomas Leitner <tom_at_finwds01.tu-graz.ac.at>
Date: Tue, 17 Feb 1998 15:24:18 +0100 (MET)

Hello,

Dr. Tom Blinn pointed me to some important omissions in my upgrade
procedure. Although it was not meant to be a precise step by step
cookbook I'll add them here to avoid confusing somebody:

- boot into single user mode with "boot -fl s"
- run bcheckrc to check and mount local file systems
  turn on swapping and start the update process

                # bcheckrc
                # swapon -a
                # update

  and depending on what you're going to be doing, you might
  want to set your system's hostname:

                # hostname xxxx.yyyyy.zzzzz

- remove the Intraserver driver with "setld -d ITPSABIN100"
- run the upgrade procedure with /sbin/installupdate
- after the reboot and the initial kernel rebuild and subset
  configuration, install the new Intraserver driver and
  rebuild the kernel

So thanks again to Dr. Tom Blinn for pointing that out.

Tom
 
--------------------------------------------------------------------------
T o m L e i t n e r Dept. of Communications
                                            Graz University of Technology,
e-mail : tom_at_finwds01.tu-graz.ac.at Inffeldgasse 12
Phone : +43-316-873-7455 A-8010 Graz / Austria / Europe
Fax : +43-316-463-697
Home page : http://wiis.tu-graz.ac.at/people/tom.html
PGP public key on : ftp://wiis.tu-graz.ac.at/pgp-keys/tom.asc or send
mail with subject "get Thomas Leitner" to pgp-public-keys_at_keys.pgp.net
--------------------------------------------------------------------------
    Before we have the paperless office, we have the paperless toilet!
Received on Tue Feb 17 1998 - 15:24:40 NZDT