On one of my 4100's I got one broadcast message saying that a redundant
power supply has failed. In user.log I see:
Jan 15 03:50:36 otdx10 syslog: Redundant Power Supply Failure.
in kern.log I see
Jan 15 03:50:36 otdx10 vmunix: ERROR: i2c_read_func_reg: enviromental
monitoring error;
Jan 15 03:50:36 otdx10 vmunix: physical sensing device not responding
properly.
so far it hasn't muttering anything else to the logs. visual inspection of
the machine (its in a cabinet) shows me zip... I'm going to call service
but am wondering how I can verify this problem (other than unplugging a PS
and seeing if the machine goes dark).
Daniel Monjar
Manager, Systems
Organon Teknika
Mailto:Daniel.Monjar_at_orgtek.com
Received on Fri Jan 15 1999 - 16:20:46 NZDT