dead power supply

From: Monjar, Daniel <Monjar_at_orgtek.com>
Date: Fri, 15 Jan 1999 11:19:52 -0500

On one of my 4100's I got one broadcast message saying that a redundant
power supply has failed. In user.log I see:

Jan 15 03:50:36 otdx10 syslog: Redundant Power Supply Failure.

in kern.log I see

Jan 15 03:50:36 otdx10 vmunix: ERROR: i2c_read_func_reg: enviromental
monitoring error;
Jan 15 03:50:36 otdx10 vmunix: physical sensing device not responding
properly.


so far it hasn't muttering anything else to the logs. visual inspection of
the machine (its in a cabinet) shows me zip... I'm going to call service
but am wondering how I can verify this problem (other than unplugging a PS
and seeing if the machine goes dark).


Daniel Monjar
Manager, Systems
Organon Teknika
Mailto:Daniel.Monjar_at_orgtek.com