Summary: Bus renumbering after upgrade causes LSM failing

From: Hellebų Knut <Knut.Hellebo_at_nho.hydro.com>
Date: Mon, 31 May 1999 08:58:06 +0200

Regards,managers !

.. and thanks.
The quick (and dirty ?) solution: renumber back the bus ids manually,
i.e in /sys/conf/HOST edit the lines

controller scsi0 at isp0 slot 0
controller scsi1 at isp1 slot 0

to

controller scsi1 at isp0 slot 0
controller scsi0 at isp1 slot 0

rebuild the kernel and reboot. The initial reason why the buses were
renumbered came to me this morning when I got to work. A Digipaq
engineer replaced some hardware long ago and then he renumbered the
buses manually before I did the LSM setup (I do not remember the reason
why). The upgrade renumbered the buses back to the order it normally is
supposed to be thus putting LSM out of order.

Thanks to all responders, especially
Fliguer, Miguel" <M_Fliguer_at_miniphone.com.ar>
alan_at_nabeth.cxo.dec.com (Alan Rollow - Dr. File System's Home for
Wayward Inodes.)
Robert Mulley <robert_at_gnsconsulting.com.au>
Oisin McGuinness <oisin_at_sbcm.com>
-- 
      ******************************************************************
      *         Knut Hellebų                     | DAMN GOOD COFFEE !! *
      *         Norsk Hydro asa                  | (and hot too)       *
      * Phone: +47 55 996870, Fax: +47 55 996495 |                     *
      * Cellular Phone: +47 93092402             |                     *
      * E-mail: Knut.Hellebo_at_nho.hydro.com       | Dale Cooper, FBI    *
      ******************************************************************
Received on Mon May 31 1999 - 07:00:30 NZST