MRU robot load failure on TZ887

From: Long, Michael <MLong_at_karmax.com>
Date: Thu, 17 Jun 1999 19:49:52 -0400

when issuing the command "robot load slot 0" I get the following error:-

LOAD failed on /dev/mc12b: Robot Illegal request. SENSE KEY: 5, ASC: 53,
ASCQ:2

I recently moved my TZ887 from an Alpha 2100 where it was working to a 4100.
Since then I have been unable to manipulate the media changer from the MRU.
I can however manipulate the media changer from the front panel of the
TZ887.

The TZ887 is at firmware 115, CLC is at version 1.3E and MRU is at version
1.3. I can see the media changer using MRU and scu :-

#scu show edt

CAM Equipment Device Table (EDT) Information:

    Device: RRD46 Bus: 0, Target: 5, Lun: 0, Type: Read-Only Direct
Access
    Device: TZ887 Bus: 1, Target: 4, Lun: 0, Type: Sequential Access
    Device: TZ Media Changer Bus: 1, Target: 4, Lun: 1, Type: Medium Changer


#robot show robot

Robot Name: /dev/mc12b Type: SCSI

Media Robot Identifier: DEC TZ Media ChangerD473

Slots: 7
Drives: 1
Inports: 0
Outports: 0
Transports: 1

# robot show slots
SLOT: 0 Full Source = Slot 0
SLOT: 1 Full Source = Slot 1
SLOT: 2 Full Source = Slot 2
SLOT: 3 Full Source = Slot 3
SLOT: 4 Empty Source = Slot 4
SLOT: 5 Empty Source = Slot 5


Any ideas??

Many thanks,

Michael Long.
Karmax Heavy Stamping
Received on Thu Jun 17 1999 - 23:50:07 NZST

This archive was generated by hypermail 2.4.0 : Wed Nov 08 2023 - 11:53:39 NZDT