Well,
my original questions was:
trying to delete unit d0 in a dual redundant hsz70 controllers, with the
> command del d0, I get this error message:
>
> 1) If I connect to the controller using lun 2 (hszterm -b 8 -t 0 -l 2)
>
> HSZterm: lun on command line switch differs from CLI string
> HSZterm: failed tosend response to remote program.
>
> 2) If I connect to the controller using lun 0 (hszterm -b 8 -t 0 -l 0)
>
> Copyright Compaq Computer Corporation 1993, 1998. All rights
> reserved.
> HSZ70 Firmware version V73Z-0, Hardware version H03
> Last fail code: 010E0110
> Press " ?" at any time for help.
> HSZ70_8F_B >
> HSZterm: Message from RD_SRVC_REQ:
> -->Device currently is opened and this operation is not allowed
> presently.<--
> HSZterm: Failed to send response to remote program.
>
> My controller is attached to bus 8, as reported by scu show edt:
>
> Device: HSZ70 Bus: 8, Target: 0, Lun: 0, Type: Direct Access
> Device: HSZ70CCL Bus: 8, Target: 0, Lun: 2, Type: Direct Access
> Device: DEC WSE BSD/V1 Bus: 8, Target: 6, Lun: 7, Type: Processor
>
> The command "show this", report the following informations:
>
> Controller:
> HSZ70 ZG92902711 Firmware V73Z-0, Hardware H03
> Configured for dual-redundancy with ZG92902586
> In dual-redundant configuration
> Device Port SCSI address 7
> Time: NOT SET
> Host port:
> SCSI target(s) (0, 1, 2, 3)
> Preferred target(s) (0, 1)
> TRANSFER_RATE_REQUESTED = 20MHZ
> Host Functionality Mode = A
> Allocation class 0
> Command Console LUN is target 0, lun 2
> Cache:
> 64 megabyte write cache, version 4
> Cache is GOOD
> Battery is GOOD
> No unflushed data in cache
> CACHE_FLUSH_TIMER = DEFAULT (10 seconds)
> NOCACHE_UPS
> Mirrored Cache:
> 64 megabyte write cache, version 4
> Cache is GOOD
> Battery is GOOD
> No unflushed data in cache
>
> I've created d0 unit only for test, now I have to delete it and create a
> raidset using the disk attached to.
> How can I do this?
> Any suggestions?
All the suggestions point me to use a terminal directly connected to the
controller via the serial port, or the StorageWorks Command Console over the
network.
I knew it, but what i forgot to say, is that my server and the controllers
are at 15 km from my office.
So, I'll try to use the Command Console from my PC.
Many thanks to you all.
---
Paolo Falchero
I.T.S. Srl - Midrange Technologies
Open System Technologies
Via Issiglio 63/A - 10141 - Torino - (Italy)
Phone: +39 11 6852840
Fax: +39 11 6853583
mailto:paolo.falchero_at_its.it
Received on Wed Nov 24 1999 - 08:09:57 NZDT