SUMMARY: Tru64 5.0A - BASE to ENHANCED conversion problem

From: Dr J Pelan <J.Pelan_at_gatsby.ucl.ac.uk>
Date: Mon, 04 Sep 2000 13:26:35 +0100 (BST)

*PROBLEM*

When attempting to convert from BASE to ENHANCED security using
'secconfig', it aborts with the following error (presumably from
'convuser'); "PUTPRPWNAM: root: Function not implemented"

*SOLUTION*

I needed to clean-up a bit more thoroughly, namely;

Uninstall the two ENHANCED (C2) packages, remove all traces of the 'tcb'
directories (in /, /var and /usr) and then reinstall -> secconfig(8) works!

The same problem was also experienced by Neil Fulton <fulton_at_misu.nodak.edu>
who suggested roughly the same clean sweep method. Thanks.

John P.
Received on Mon Sep 04 2000 - 12:34:46 NZST

This archive was generated by hypermail 2.4.0 : Wed Nov 08 2023 - 11:53:41 NZDT