SUMMARY: HSG80 and SAN

From: <Eskil.Swahn_at_LDC.lu.se>
Date: Tue, 26 Sep 2000 08:32:51 +0200 (MEST)

Hi!

As usual, thanks to all who replied.

The original problem was a newly upgraded HSZ70->HSG80 which I couldn't
communicate with in a SAN.

The solution was that 4.0F can only communicate with 8 devices and in the
FibreChannel case this involves the KGPSAs on the other machines. Hence
with three controllers and six machines I had one too many and since I had
upgraded the controller last, it was stuck at place number nine in the
database (/etc/emx.info is the humanreadable form, see man emx(4) for more
information). I cleared the database and turned on of the machines off to
make sure that the machine that I needed to speak with the last controller
got contact with it. Included in TruCluster (according to Compaq's
website) is a program called 'emxmgr' which allows you to manipulate and
display the database. My local Compaq contact is currently investigating
why this isn't available outside of the TruCluster software.

/Eskil

+--------------------------------------------------------------------+
| |
| Eskil Swahn |
| LDC, Lund University |
| Email: Eskil.Swahn_at_LDC.lu.se Web: http://www.ldc.lu.se/ |
| Phone: +46 46 222 4986 Fax: +46 46 138225 |
| |
+--------------------------------------------------------------------+