Managers,
Last night we lost power to the HSZ70. Today when power was restored
and I log into the HSZ70 I get this error: This controller has an invalid
cache module. Receivied LAST GASP message from the other controller. Last
Failure code 018700A0. When I try to bring up the
ES-40 I get this error: cam_logger: CAM_ERROR packet
cam_logger: bus 0 target 0 lun 0
ss_perform_timeout
I have placed a call to Compaq but I'm getting pressure from upstairs so
thought I would give you
people a try. Any help would be appreciated.
Jerry Brady, Low level system flunkie
Received on Thu Nov 09 2000 - 16:19:01 NZDT