urgent Q - HSZ unit set "inoperative"

From: Christian Wessely <christian.wessely_at_uni-graz.at>
Date: Mon, 11 Feb 2002 09:05:32 +0100

Hi Admin Wizards,

on saturday we had a blackout and the PSU seems to have failed.
Anyway, when I came back to office today I saw that TruCluster was not
running,
from the HSZ40 Terminal I saw that for some reason the two raid units d100
and d200 are set as "state: inoperative".
Since there is no evidence for physical damage, I am looking for a
possibility to reset the units to operative without loosing data on it, if
possible.
I would be very grateful for a quick hint. The manual indicates to use
DILX, but I would prefer to do it in a soft way because I figure that there
is some possibility to loose data when using dilx ... any idea anyone?
Pretty please with sugar on top ...

regards,




YS, CW


------------------------------------------
Dr. Christian Wessely
christian.wessely_at_uni-graz.at
url: www-theol.uni-graz.at
PGP Public Keys deposed there
Received on Mon Feb 11 2002 - 08:02:12 NZDT