WG: EVM ALERT [600]: AdvFS: An AdvFS domain panic has occurred on data_domain

From: <stephane.moser_at_ruag.com>
Date: Thu, 14 Nov 2002 16:09:51 +0100

Hi

Still a bit of information. After the reboot of both nodes was my AdvFS
domain again alright. So actually I have no problem but I would like to know
why that Problem happened.

Can I use "verify <domain name>" online?

Thanks

Best regards,

Stephane




-----Ursprungliche Nachricht-----
Von: Moser Stephane RUAG M
Gesendet: Thursday, November 14, 2002 3:46 PM
An: 'tru64-unix-managers_at_ornl.gov'
Betreff: WG: EVM ALERT [600]: AdvFS: An AdvFS domain panic has occurred
on data_domain


Hi

I little bit more information:

The disk /dev/disk/dsk9c is in a SAN (StorageWorks - HSG80)

In /var/adm/messages I found the following messages:

Nov 14 14:00:06 vmunix: drd_handle_eei: Device 177. errno 5Uninterpreted
b_eei value 0x100.
Nov 14 14:00:06 vmunix: AdvFS I/O error:
Nov 14 14:00:06 vmunix: Volume: /dev/disk/dsk9c
Nov 14 14:00:06 vmunix: Tag: 0xfffffff0.0000
Nov 14 14:00:06 vmunix: Page: 3265
Nov 14 14:00:06 vmunix: Block: 17628976
Nov 14 14:00:06 vmunix: Block count: 16
Nov 14 14:00:06 vmunix: Type of operation: Write
Nov 14 14:00:06 vmunix: Error: 5
Nov 14 14:00:06 vmunix: EEI: 0x100
Nov 14 14:00:06 vmunix:
Nov 14 14:00:06 vmunix: bs_osf_complete: metadata write failed
Nov 14 14:00:06 vmunix: AdvFS Domain Panic; Domain data_domain Id
0x3cb1981d.010c2299
Nov 14 14:00:06 vmunix: An AdvFS domain panic has occurred due to either a
metadata write error or an internal
 inconsistency. This domain is being rendered inaccessible.
Nov 14 14:00:06 vmunix: AdvFS I/O error:
Nov 14 14:00:06 vmunix: A read failure occurred - the AdvFS domain is
inaccessible (paniced)
Nov 14 14:00:06 vmunix: Volume: /dev/disk/dsk9c
Nov 14 14:00:06 vmunix: Tag: 0xfffffff0.0000
Nov 14 14:00:06 vmunix: Page: 122
Nov 14 14:00:06 vmunix: Block: 17580736
Nov 14 14:00:06 vmunix: Block count: 16
Nov 14 14:00:06 vmunix: Type of operation: Read
Nov 14 14:00:06 vmunix: Error: 5
Nov 14 14:00:06 vmunix: EEI: 0x300

Thanks.

Best regards,

Stephane




-----Ursprungliche Nachricht-----
Von: Moser Stephane RUAG M
Gesendet: Thursday, November 14, 2002 3:18 PM
An: 'tru64-unix-managers_at_ornl.gov'
Betreff: WG: EVM ALERT [600]: AdvFS: An AdvFS domain panic has occurred
on data_domain


Hi everybody

On my TruCluster v51a (Patch Kit 1) I had an AdvFS domain panic (see below).

Any idea ... patches ?

In advance Thanks

Best regards,

Stephane



============================ EVM Log event ===========================
EVM event name: sys.unix.fs.advfs.fdmn.panic

    This event is posted by the AdvFS filesystem to indicate that an
    AdvFS domain panic has occurred on the specified domain. This is
    due to either a metadata write error or an internal inconsistency.
    The domain is being rendered inaccessible.

    Action: Please refer to the guidelines in the AdvFS Guide to File
    System Administration for the steps to recover this domain.

======================================================================

Formatted Message:
    AdvFS: An AdvFS domain panic has occurred on data_domain

Event Data Items:
    Event Name : sys.unix.fs.advfs.fdmn.panic
    Cluster Event : True
    Priority : 600
    PID : 524288
    PPID : 0
    Event Id : 139174
    Member Id : 1
    Timestamp : 14-Nov-2002 14:00:06
    Host IP address : <IP>
    Cluster IP address: <IP>
    Host Name : <Name>
    Cluster Name : <Name>
    Format : AdvFS: An AdvFS domain panic has occurred on $domain
    Reference : cat:evmexp.cat:450

Variable Items:
    domain (STRING) = "data_domain"

======================================================================
Received on Thu Nov 14 2002 - 15:10:47 NZDT