Hi
I hope, that will be the last time but I noticed that I receive regularly
the following message on my HSG80 prompt. I have never seen such a message
until today.
Any idea?
Thanks a lot for your help.
Best regards,
Stéphane
--14-NOV-2002 16:04:59-- Instance Code: 0258000A
Template: 81.(51)
Occurred on 14-NOV-2002 at 16:04:59
Power On Time: 2. Years, 264. Days, 12. Hours, 34. Minutes, 40. Seconds
Controller Model: HSG80
Serial Number: ZG93609121 Hardware Version: E10(28)
Software Version: V86F-7(BA)
Informational Report
Unit Number: 7.(0007)
Unit Software Version: 1.(01) Unit Hardware Version: 49.(31)
Retry Level: 1. Retries: 1.
Port: 4. Target: 0. LUN: 0.
SCSI Device Type: 0.(00)
Device ID: "BD036635C5" Device Serial Number: " 0126"
Device Software Revision Level: "B021"
SCSI Command Opcode: 40.(28)
Sense Data Qualifiers: 64.(40)
SCSI Sense Data:
Error Code: 112.(70) {current command execution}
Information field is valid
Segment: 0.(00)
Sense Key: 11.(0B) ABORTED COMMAND
ILI: 0 EOM: 0 FM: 0
Information: 60879904
Additional Sense Length: 10.(0A)
Command-Specific Information: 00000000
ASC: 0.(00) ASCQ: 6.(06)
FRU: 0.(00) Sense-Key Specific: 000000
Instance Code: 0258000A
--14-NOV-2002 16:04:59-- Instance Code: 0258000A
Template: 81.(51)
Occurred on 14-NOV-2002 at 16:04:59
Power On Time: 2. Years, 264. Days, 12. Hours, 34. Minutes, 40. Seconds
Controller Model: HSG80
Serial Number: ZG93609121 Hardware Version: E10(28)
Software Version: V86F-7(BA)
Informational Report
Unit Number: 7.(0007)
Unit Software Version: 1.(01) Unit Hardware Version: 49.(31)
Retry Level: 1. Retries: 1.
Port: 4. Target: 0. LUN: 0.
SCSI Device Type: 0.(00)
Device ID: "BD036635C5" Device Serial Number: " 0126"
Device Software Revision Level: "B021"
SCSI Command Opcode: 40.(28)
Sense Data Qualifiers: 64.(40)
SCSI Sense Data:
Error Code: 112.(70) {current command execution}
Information field is valid
Segment: 0.(00)
Sense Key: 11.(0B) ABORTED COMMAND
ILI: 0 EOM: 0 FM: 0
Information: 60879904
Additional Sense Length: 10.(0A)
Command-Specific Information: 00000000
ASC: 0.(00) ASCQ: 6.(06)
FRU: 0.(00) Sense-Key Specific: 000000
Instance Code: 0258000A
-----Original Message-----
From: stephane.moser_at_ruag.com [mailto:stephane.moser_at_ruag.com]
Sent: Thursday, November 14, 2002 8:46 AM
To: tru64-unix-managers_at_ornl.gov
Subject: WG: EVM ALERT [600]: AdvFS: An AdvFS domain panic has occurred
on data_domain
Hi
I little bit more information:
The disk /dev/disk/dsk9c is in a SAN (StorageWorks - HSG80)
In /var/adm/messages I found the following messages:
Nov 14 14:00:06 vmunix: drd_handle_eei: Device 177. errno 5Uninterpreted
b_eei value 0x100.
Nov 14 14:00:06 vmunix: AdvFS I/O error:
Nov 14 14:00:06 vmunix: Volume: /dev/disk/dsk9c
Nov 14 14:00:06 vmunix: Tag: 0xfffffff0.0000
Nov 14 14:00:06 vmunix: Page: 3265
Nov 14 14:00:06 vmunix: Block: 17628976
Nov 14 14:00:06 vmunix: Block count: 16
Nov 14 14:00:06 vmunix: Type of operation: Write
Nov 14 14:00:06 vmunix: Error: 5
Nov 14 14:00:06 vmunix: EEI: 0x100
Nov 14 14:00:06 vmunix:
Nov 14 14:00:06 vmunix: bs_osf_complete: metadata write failed
Nov 14 14:00:06 vmunix: AdvFS Domain Panic; Domain data_domain Id
0x3cb1981d.010c2299
Nov 14 14:00:06 vmunix: An AdvFS domain panic has occurred due to either a
metadata write error or an internal
inconsistency. This domain is being rendered inaccessible.
Nov 14 14:00:06 vmunix: AdvFS I/O error:
Nov 14 14:00:06 vmunix: A read failure occurred - the AdvFS domain is
inaccessible (paniced)
Nov 14 14:00:06 vmunix: Volume: /dev/disk/dsk9c
Nov 14 14:00:06 vmunix: Tag: 0xfffffff0.0000
Nov 14 14:00:06 vmunix: Page: 122
Nov 14 14:00:06 vmunix: Block: 17580736
Nov 14 14:00:06 vmunix: Block count: 16
Nov 14 14:00:06 vmunix: Type of operation: Read
Nov 14 14:00:06 vmunix: Error: 5
Nov 14 14:00:06 vmunix: EEI: 0x300
Thanks.
Best regards,
Stephane
-----Ursprungliche Nachricht-----
Von: Moser Stephane RUAG M
Gesendet: Thursday, November 14, 2002 3:18 PM
An: 'tru64-unix-managers_at_ornl.gov'
Betreff: WG: EVM ALERT [600]: AdvFS: An AdvFS domain panic has occurred
on data_domain
Hi everybody
On my TruCluster v51a (Patch Kit 1) I had an AdvFS domain panic (see below).
Any idea ... patches ?
In advance Thanks
Best regards,
Stephane
============================ EVM Log event ===========================
EVM event name: sys.unix.fs.advfs.fdmn.panic
This event is posted by the AdvFS filesystem to indicate that an
AdvFS domain panic has occurred on the specified domain. This is
due to either a metadata write error or an internal inconsistency.
The domain is being rendered inaccessible.
Action: Please refer to the guidelines in the AdvFS Guide to File
System Administration for the steps to recover this domain.
======================================================================
Formatted Message:
AdvFS: An AdvFS domain panic has occurred on data_domain
Event Data Items:
Event Name : sys.unix.fs.advfs.fdmn.panic
Cluster Event : True
Priority : 600
PID : 524288
PPID : 0
Event Id : 139174
Member Id : 1
Timestamp : 14-Nov-2002 14:00:06
Host IP address : <IP>
Cluster IP address: <IP>
Host Name : <Name>
Cluster Name : <Name>
Format : AdvFS: An AdvFS domain panic has occurred on $domain
Reference : cat:evmexp.cat:450
Variable Items:
domain (STRING) = "data_domain"
======================================================================
Received on Thu Nov 14 2002 - 15:16:06 NZDT