Hi netters,
after installing patch kit 3 of Tru64 5.1a (all patches), the Generic
batch
queuing system (3.50.9) stopps working (the pipeclient spawn is no longer
working; the control file data of the jobs, which are transferred by
filehandle stdin from the nqsdaemon to the pipeclient can t be read
anymore; i.e the input stream is empty and the jobs fails (failed
directory)
with a message Cant take input from a terminal).
Has anyone a hint what could have changed?
Regards,
Rudolf Gabler
email:rug_at_usm.uni-muenchen.de
WorldWideWeb:
http://www.usm.uni-muenchen.de/people/rug/rug.html
Received on Thu Dec 05 2002 - 12:56:59 NZDT