-- Dr. Andrew Raine, Head of IT, MRC Dunn Human Nutrition Unit, Wellcome Trust/MRC Building, Hills Road, Cambridge, CB2 2XY, UK phone: +44 (0)1223 252830 fax: +44 (0)1223 252835 web: www.mrc-dunn.cam.ac.uk email: Andrew.Raine_at_mrc-dunn.cam.ac.uk Event log message on HSG80 console: %EVL--HSG--24-JAN-2003 14:47:13-- Instance Code: 030C4002 Template: 81.(51) Occurred on 24-JAN-2003 at 14:47:13 Power On Time: 0. Years, 134. Days, 11. Hours, 58. Minutes, 56. Seconds Controller Model: HSG80 Serial Number: ZG02804764 Hardware Version: E12(2A) Software Version: V86F-10(BA) Unit Number: 111.(006F) Unit Software Version: 1.(01) Unit Hardware Version: 56.(38) Retry Level: 1. Retries: 0. Port: 1. Target: 11. LUN: 0. SCSI Device Type: 31.(1F) Device ID: "BD03664553" Device Serial Number: "2248CD8W" Device Software Revision Level: "3B08" SCSI Command Opcode: 0.(00) Sense Data Qualifiers: 0.(00) SCSI Sense Data: Error Code: 0.(00) {reserved} Information field is invalid Segment: 0.(00) Sense Key: 4.(04) HARDWARE ERROR ILI: 0 EOM: 0 FM: 0 Information: 00000000 Additional Sense Length: 0.(00) Command-Specific Information: 00000000 ASC: 63.(3F) ASCQ: 133.(85) FRU: 0.(00) Sense-Key Specific: 000000 Instance Code: 030C4002Received on Mon Jan 27 2003 - 14:13:09 NZDT
This archive was generated by hypermail 2.4.0 : Wed Nov 08 2023 - 11:53:44 NZDT