1 July 1996
While every effort has been made to ensure the accuracy of
the material, this is old information and no one is responible for
any inadvertent errors.
Introduction
Only cables which are of current interest have been included,
so the list of entries is not exhaustive. The contents have been
sourced from previous guides, from technical publications, and,
from in-house investigation. Where cable data is not easily resourced,
the technical data is incomplete, but hopefully still of value.
Please note that this publication is for guidance only and does
not include full engineering specifications.
Cables Reference Guide - Contents by Alpha-numeric Order (*
indicates addition since last guide)
-
Introduction
-
Content by cable group
-
General Notes - Ordering Codes
-
Speed and Distance Considerations
-
Digital's Standard Synchronous Connector
-
Synchronous Cables Summary
-
BC06P SCSI Cable
-
BC09D SCSI Cable
-
BC09J SCSI Cable
-
BC09K SCSI Cable
-
BC09R EtherWORKS Router Adapter Cable
-
BC09S EtherWORKS Router Adapter Cable
-
BC09T EtherWORKS Router Adapter Cable
-
BC09U Eicon PC RS232-C Modem Cable
-
BC09V Eicon HSI V.24 Modem Cable
-
BC09W Eicon HSI V.35 Modem Cable
-
BC09X Eicon HSI X.21 Modem Cable
-
BC12F DECbrouter 90 X.21 Adapter Cable
-
BC12G DECbrouter 90 V.35 Adapter Cable
-
BC12H DECbrouter 90 RS422 Adapter Cable
-
BC12J DECbrouter 90 EIA 530A Adapter Cable
-
BC12K DECbrouter 90 RS423 Adapter Cable
-
BC12L DECbrouter 90 RS232 Adapter Cable
-
BC12N MemoryChannel Cable
-
BC13L Video Cable for Color Monitor
-
BC13M Keyboard / Mouse Extender Cable
-
BC16C / BC16D DEC423 "Harmonica" Cables
-
BC16E DEC423 "Office" Cable
-
BC16K Thinwire Patching Cable
-
BC16M Thinwire Cable
-
BC19B EIA-422 Adapter Cable
-
BC19C X.21 Adapter Cable
-
BC19D V.24 Adapter Cable
-
BC19E EIA-423 Adapter Cable
-
BC19F V.35 Adapter Cable
-
BC19J SCSI Cable
-
BC19L V.35 Communications Cable
-
BC19M IBM PC Parallel Interface Cable
-
BC19N EIA-232 "One-To-Four" Cable
-
BC19S Cable for Color Monitor
-
BC19Y EIA-422 Null Modem Cable
-
BC21G BT Kilostream Cable
-
BC21M DSSI Cable
-
BC21Q DSSI Cable
-
BC22D Terminal Cable
-
BC22E Modem Cable
-
BC22F Modem Cable
-
BC22H Gender Changer Cable
-
BC22R EIA-232 Null Modem (CTS/RTS) Cable
-
BC22Q DSSI Cable
-
BC22X X.21 Adapter Cable.
-
BC22Z X.21 Communications Cable
-
BC23J Video Cable for Color Monitor
-
BC23P DEC423 "Octopus" Cable
-
BC25R Internal SCSI Cable
-
BC25T Wide SCSI Cable
-
BC25U Internal SCSI Cable
-
BC27A Line Printer Cable
-
BC27M Monochrome Monitor Cable
-
BC27Z RapidPrint 200 to Dataproduct Line Printer Cable
-
BC29G Color Monitor Cable
-
BC29H Color Monitor Cable
-
BC29P PC Modem Cable
-
BC29Q PC Null-modem Cable
-
BC29R DSSI Cable for HSD
-
BC29S DSSI Cable for HSD
-
BC29T DSSI Cable for StorageWorks Cabinet
-
BC29U DSSI Cable for StorageWorks Cabinet
-
BC29V HSD30 Link Cable
-
BC42A Convenience Power Cable
-
BC55D EIA-422/423 Communications Cable
-
BC56H SCSI Adapter Cable
-
BCC04 / BCC14 EIA-232 Modem Cables
-
BCC05 Printer Cable
-
BCC27 VRT13 Color Monitor Cable
-
BCC45 PC Keyboard Extension Cable
-
BN12A Power Cable
-
BN18B Power Cable
-
BN19A Power Cable
-
BN19B Power Cable
-
BN20E Power Cable
-
BN21H SCSI Cable
-
BN21J SCSI Cable
-
BN21K Differential SCSI Cable
-
BN21L Differential SCSI Cable
-
BN21M SCSI Cable
-
BN21N SCSI Cable
-
BN21P-0B SCSI "Y" Cable
-
BN21P-02 SCSI Adapter Cable
-
BN21R Fast SCSI Cable
-
BN21V SCSI "Y" Adapter Cable
-
BN21W SCSI "Y" Adapter Cable
-
BN21X SCSI Adapter Cable
-
BN21Y SCSI "Y" Adapter
-
BN22E Power Cable
-
BN23G Fast SCSI Cable
-
BN24A Thin Wire Daisy Chain Cable
-
BN24B FDDI To FDDI Cable Assembly
-
BN24D FDDI To ST Cable Assembly
-
BN24E Dual ST Cable Assembly
-
BN24F 10BaseT Office Cable
-
BN24H DEC423 Office Cable
-
BN24J DEC423 Equipment Cable
-
BN24K DEC423 Equipment Cable
-
BN24L DEC423 Equipment Cable
-
BN24N DEC423 Equipment Cable
-
BN24Q 100BseT or 10BaseT Cable
-
BN25G 10BaseT Equipment Cable
-
BN25H Copper FDDI Cable
-
BN26M High Performance Office Cable
-
BN26N 10BaseT Office Cable
-
BN26R Octopus Cable
-
BN26S Copper FDDI Cable (Shielded)
-
BN26U 10baseT Octopus Adaptor Cable
-
BN31G SCSI Cable
-
BN31K KZPSC Cable/Bulkhead Assembly
-
BN31L Single-ended SCSI Cable
-
BN31M Single-ended SCSI Cable
-
BN31S Single-ended SCSI Cable
-
BN31V SCSI Cable
-
BN31W SCSI Cable
-
BN34A Dual ST-SC Fibre-Optic Cable
-
BN34B Dual SC-SC Fibre-Optic Cable
-
BN34C Dual ST-ST Fibre-Optic Cable
-
BN34D MIC-SC Fibre-Optic Cable
-
BN36A SCSI Adapter Cable
-
BN41A DECserver900GM Octopus Cable
-
BN41B DECserver900GM Octopus Cable
-
BN41C DECserver900GM Adapter Cable
-
BN41D DECserver900GM Adapter Cable
-
BNCIA CI Cable Set
-
BNE2A / BNE2B Ethernet Cable
-
BNE3x / BNE4x Transceiver Cable
-
BS19D EIA-232 Adapter Cable Kit
-
BS23V V.24 / V.28 Adapter Cable Kit
-
H8240 Flat 6-Conductor Cable
-
H8240-A UTP High Performance Data Grade Cable
-
H8240-B STP High Performance Data Grade Cable
-
H8245-A / H8246-A UTP Standard Data Grade Cable
-
H8245-C / H8246-C UTP High Performance Data Grade Cable
-
H8245-D / H8246-D STP High Performance Data Grade Cable
-
H8571-C/D Passive Adapter Wiring Diagram
-
Appendix A - EIA Standards, Speed and Distance
-
Appendix B - EIA-232 Signal/Pin Designations
-
Appendix C - Terminal Server Adaptors
-
Appendix D - OPEN DECconnect Sample Configurations
-
Appendix E - Digitals Multi-Standard 50-pin Synchronous Interface for WAN (Wide Area Network) Devices
-
Appendix F - Ethernet Cable Parts
-
Appendix G - "Confusable" Cable Summary
-
Appendix H - Fibre Optic Notes
-
Appendix I - DSSI Connections
-
Appendix J - SCSI Device Connector Types
-
Appendix K - Summary of SCSI Cables
-
Appendix L - SCSI and DSSI Terminators and Tri-link Adaptors
Cables Reference Guide - Contents by Cable
Group
This table is provided for easy reference of cable by usage group,
please note that it does not include all cables from the Cables
Reference Guide.
-
Building/Office cables
-
Communications cables
-
DEC423 cables
-
DSSI cables
-
Ethernet cables
-
Fibre Optic cables
-
ISDN cables
-
MemoryChannel Cables
-
Modem/Null-Modem cables
-
Monitor cables
-
PC Specific cables
-
Power cables
-
SCSI Cables `
-
SDI/STI cables
-
Terminal and Printer cables
-
10baseT cables
SCSI
-
BC06P Single-ended 50LD - 50LD
-
BC09D Single-ended, Transition 50LD - 50HD
-
BC09J Single-ended, Transition 50LD - 68HD
-
BC09K Single-ended 50LD - 50LD
-
BC19J Single-ended 50LD - 50LD
-
BC25T Wide 68RCC - 68RCC
-
BC56H Single-ended, Transition 68HD - 50LD
-
BN21H Single-ended 50HD - 50HD
-
BN21J Single-ended 50HD - 50HD
-
BN21K Differential 68HD - 68HD
-
BN21L Differential 68HD - 68HD
-
BN21M Transition 68HD - 50LD
-
BN21N Transition 68HD - 50HD
-
BN21P VAXstation 3100 only 68HD - 50HD
-
BN21R Single-ended,Transition 50HD - 50LD
-
BN21V Single ended, "Y" 50HD + 2 X 50LD
-
BN21W Single ended, "Y" 68HD + 2 X 68 HD
-
BN21X Single Ended "T" 50HD + 2 X 68HD
-
BN21Y Single ended, "Y" 50LD + 2 X 50LD
-
BN23G Single-ended, Transition 50HD - 50LD
-
BN31G General Purpose SCSI
-
BN31K Wide Bulkhead Kit 68RCC - 68VHD
-
BN31L Single-ended 68VHD - 50HD
-
BN31M Single-ended 68VHD - 68HD
-
BN31S Single-ended 68VHD - 68HD
-
BN31V General Purpose Fast SCSI
-
BN31W General Purpose Fast SCSI
-
BN36A SCSI Adapter Cable
-
Appendix J - Summary of SCSI Device Connector Types
-
Appendix K - Summary of SCSI Cables
-
Appendix L - Terminators and Tri-link Adaptors
-
Where: 68HD is a 68-way High Density or Honda connector
-
50LD is a 50-way low-density or Centronics style connector
-
68VHD is a 68-way very high density (0.8mm pitch)
-
68RCC is a 68-way IDC Ribbon Cable Connector.
DSSI
-
BC21M Inter-cabinet
-
BC21Q Inter-cabinet
-
BC22Q Inter-cabinet
-
BC29R HSDxx
-
BC29S HSDxx
-
BC29T StorageWorks cabinet
-
BC29U StorageWorks cabinet
-
BC29V HSD30 Controller link
-
Appendix I DSSI Cabling Summary
-
Appendix L Terminators and Tri-link Adaptors
PC Specific
-
BC09R Router RS232, RS422 Adapter
-
BC09S Router RS232 Adapter
-
BC09T Router RS422 Adapter
-
BC09U X.25 RS232 Adapter
-
BC09V X.25 HSI RS232 Adapter
-
BC09W X.25 HSI V.35 Adapter
-
BC09X X.25 HSI X.21 Adapter
-
BC19M Parallel printer
-
BC29P Modem
-
BC29Q Null Modem
-
BCC45 Keyboard Extension
MemoryChannel
- BC12N MemoryChannel Link Cable
Communications
-
BC12F DECbrouter90 X.21 Adapter
-
BC12G DECbrouter90 V.35 Adapter
-
BC12H DECBrouter90 RS422 Adapter
-
BC12J DECBrouter90 EIA530 Adapter
-
BC12K DECBrouter90 RS423 Adapter
-
BC12L DECBrouter90 RS232 Adapter
-
BC19B DECWAN RS422 Adapter
-
BC19C DECWAN X.21 Adapter
-
BC19D DECWAN V.24 Adapter
-
BC19E DECWAN RS423 Adapter
-
BC19F DECWAN V.35 Adapter
-
BC19L V.35 Extension
-
BC21G BT Kilostream Adapter
-
BC22X BT Kilostream Adapter
-
BC22Z X.21/Kilostream Extension
-
BC55D EIA422/423 Extension
-
BN41A DECserver900GM Octopus Cable
-
BN41B DECserver900GM Octopus Cable
-
BN41C DECserver900GM Adapter Cable
-
BN41D DECserver900GM Adapter Cable
-
BS19D DECWAN RS232 Adapter Kit
-
BS23V DECWAN RS232 Adapter Kit
ISDN
- BN25G Office cable - straight
Modem/Null-Modem
-
BC19Y Null-Modem, RS422
-
BC22D Null-Modem, RS232
-
BC22E Modem, RS232, Asynchronous
-
BC22F Modem, RS232, Synchronous
-
BC22R Null-Modem RS232, (CTS/RTS)
-
BC29P PC Modem
-
BC29Q PC Null Modem
-
BCC04 Modem, RS232
-
BCC14 Modem, RS232
Ethernet (see also "10BaseT")
-
BC16K ThinWire patching BC16M ThinWire
-
BC16M ThinWire
-
BN24A ThinWire Daisy-chain
-
BNE2A/B ThickWire
-
BNE3x/4x Transceiver
-
BNE4G EtherWorks Tranceiver
-
Appendix F Ethernet Cable Summary
10BaseT
-
BN24F Office - crossed
-
BN24Q Straight
-
BN25G Straight
-
BN26M Straight
-
BN26N Crossed
-
BN26R Octopus
-
BN26U Octopus
Terminals/Printers (see also "DEC423")
-
BC13M Keyboard/Mouse Extender
-
BC16E DEC423
-
BC19M Centronics Parallel
-
BC22D RS232
-
BC27A Dataproducts Parallel
-
BC27Z RapidPrint 200 to Dataproduct Line Printer Cable
-
BCC05 VT2xx or DECmate to Printer
-
BCC46 Apple Macintosh to Printer
-
BN24H DEC423 MMP - MP
DEC423
-
BC16E MMP - MMP, crossed
-
BN24H MMP - MP , crossed
-
BN24J MMP - MP , straight
-
BN24K 36 conductor cable
-
BN24L Octopus
-
BN24N Octopus
-
BN26R Octopus
Fibre Optic
-
BN24B MIC to MIC
-
BN24D MIC to ST (Bayonet)
-
BN24E ST to ST (Bayonet)
-
BN25H MP8 to MP8
-
BN26S (S)MP8 to (S)MP8
-
BN34A SC to ST (Push-pull)
-
BN34B SC to SC
-
BN34C ST to ST (Push-pull)
-
BN34D MIC to SC (Push-pull)
Appendix H Fibre Optic Notes
Power
-
BC42A Convenience/Jumper
-
BN12A Special use
-
BN18B HSC use
-
BN19A General Purpose
-
BN19B General Purpose
-
BN20E Special Use
-
BN22E Special use
-
BN26D General Purpose (See BN19A)
Monitor
-
BC13L Color Monitor Cable
-
BC19S Color, keyboard, mouse
-
BC23J Color
-
BC27M Monochrome
-
BC29G Color
-
BC29H Color
-
BCC27 VTR13 Color
Building/Office Cable supplied on reel.
-
H8240 Flat 6-conductors for DEC423 use.
-
H8240-A UTP High Performance Data Grade. Category 5.
-
H8240-B STP High Performance Data Grade. Category 5.
-
H8245-A UTP Standard Data Grade, (pvc). Category 3.
-
H8246-A UTP Standard Data Grade, (teflon). Category 3.
-
H8245-C UTP High Performance, high speed, Data Grade. Category 5.
-
H8246-C UTP High Performance, high speed, Data Grade, (teflon). Category 5.
-
H8245-D STP High Performance Data Grade. Category 5.
-
H8246-D STP High Performance Data Grade (teflon)
General Notes
Cable option numbers tend to be of the format:
BCxxx-yy or BNxxx-zz
where the "C" indicates that the suffix "yy"
describes the length of the cable in feet, for example
BC21M-09...is a BC21M cable 9 feet long, and the "N"
means the length "zz" is described in meters.
BN25B-30 is a BN25B cable 30 metres long.
Some cable options are prefixed with an "E0" identifier,
this simply indicates the European origin of the cable, for example
E0-BCC05-50 is a 50 feet long BCC05 sourced in Europe.
Other Cable Lengths
Letters may be used for cable lengths, eg,
A = 100,
B = 200,
C = 300,
D = 400,
E = 500,
H = 700,
L = 1000,
for example
-A5 = 150,
-B5 = 250,
-C0 = 300,
-H5 = 750,
-L0 = 1000, so.......
BN25B-H5 is a 750m BN25B cable, and BC22D-B5 is 250 feet long
BC22D.
These letters may also be used to indicate decimals or feet and
inches, thus BN19A-2E is a 2.5m BN19A, and BC26V-6D is a 6 feet
4 inches long BC26V.
BC06P SCSI Cable
BC06P
Description:
Single-ended SCSI cable.
Specification:
Number Of Conductors 50 conductors, plus shielding.
Connectors Two 50-way, low density, Centronics style, right-angled
to the right connectors.
Wiring Pin to Pin.
Typical Usage To connect an RRD42 CDROM drive to a KZQSA adapter
in a Q-bus host system.
Ordering Information BC06P-2F, BC06P-06, BC06P-09 (feet).
(17-02659-03, -02, -01)
BC09D SCSI Cable
BC09D
Description:
SCSI cable using single-ended electrical signals. This is a transition
cable, so called because it
provides a transition between different connector types.
Important Note. Use the BN23G cable for fast SCSI applications.
See BN23G for entry details.
Specification:
Connectors One male, 50-way, high-density, Honda, straight, with
thumb latches. One male 50-way Centronics
style, low-density, straight, connector with bale locks.
Typical Usage To connect a BA350 StorageWorks storage shelf to
a host system.
NOTE : As the BA350 shelf has a 50-way, high-density female connector
which is directly on the
backplane, only a a cable with a straight 50-way, high-density
male connector can be attached to it.
Ordering Information BC09D-03, -06, -12 (feet). (17-02641-01,
-02, -03).
This cable is shipped with DECstation 5000 models 100 and 125.
BC09J SCSI Cable
BC09J
Description:
Single-ended, three feet long, SCSI cable.
Connectors One 50-way, low-density, Centronics style, right-angled
connector; one 68-way, high density,
Honda, straight, female connector.
Ordering Information BC09J-03 (feet) (17-02443-01)
This cable is supplied along with the BC09K-02 in SZ12 Expansion
Enclosures.
BC09K SCSI Cable
BC09K
Description:
Single-ended SCSI cable, two feet long.
Connectors Two 50-way, low-density, Centronics style, right-angled
to the left connectors.
Typical Usage Connects SZ12 Expansion Enclosures together.
Ordering Information BC09K-02 (17-02446-02).
This cable, along with the BC09J-03, is shipped with the SZ12
Expansion Enclosures. It is
also shipped with the SZ16 Expansion Enclosure.
BC09R EtherWORKS Router RS232 & RS422
Adapter Cable
BC09R
Description:
"V" cable used to adapt the single serial communications
port
of the DE206 EtherWORKS Router to one RS422, and one RS232 connection.
Each "leg" of the "V" is 3 feet in length.
Specifications:
Connectors 68-way high-density "Honda" male at
the point of the "V", with one
37-way D-type male, and one 25-way D-type male connector terminating
each "leg" of the
"V" cable.
Usage Adapts the 68-way multi-standard serial communications
port of the DE206-AA EtherWORKS
Router to one RS422 modem connection, and one RS232 modem connection.
The BC21G-02 RS422 to BT Kilostream
Adapter Cable may in turn be added to the 37-way RS422 end of
the BC09R cable for connection to a
Network Terminating Unit (NTU) for Kilostream use.
Ordering Information BC09R-03 (17-03133-01).
BC09S EtherWORKS Router RS232 Adapter Cable
BC09S
Description:
"V" cable used to adapt the single serial communication
port of the DE206
EtherWORKS Router to two RS232 connections.
Each "leg" of the "V" is 3 feet in length.
Specification:
Connectors 68-way high density, "Honda" male at the
point of the "V", and two 25-way
D-type male connectors terminating each leg of the "V".
Usage Adapts the 68-way multi-standard serial communications port
of the DE206-AA EtherWORKS
Router to one or two RS232 modem connections.
Ordering Information BC09S-03 (17-03134-01).
BC09T EtherWORKS Router RS422 Adapter Cable
BC09T
Description:
"V" cable used to adapt the single serial communications
port of the DE206 EtherWORKS Router to two RS449/RS422 connections.
Each "leg" of the "V" is 3 feet in length.
Specifications:
Connectors 68-way high density "Honda" male at the point
of the "V", and two 37-way D-type male connectors terminating
each leg of the "V".
Usage:
Adapts the 68-way multi-standard serial communications port of
the DE206-AA EtherWORKS Router to one or two RS449/RS422 modem
connections. The BC21G-02 RS422 to BT Kilostream Adapter Cable
may in turn be connected to one end of the BC09T-03 cable for
connection to a Network Terminating Unit (NTU) for Kilostream
use.
Ordering Information:
BC09T-03 (17-03135-01).
BC09U Eicon PC RS232-C Modem Cable
BC09U
Description:
A modem cable designed to connect the DS206-AA Eicon PC X.25
Network Controller to an RS232 modem.
Specification:
Connectors 25-way male D-type connector, with screw fixings, at
both ends.
Ordering Information BC09U-10.
BC09V Eicon HSI V.24 Modem Cable
BC09V
Description:
A modem cable designed to connect the DS206-CA Eicon X.25 Network
Controller to a V.24 modem.
Specification:
Connectors 26-way male D-type connector at the DS206 controller
end, 25-way
D-type male connector at the V.24 modem end. Both connectors have
screw type
fixings.
Ordering Information BC09V-10.
BC09W Eicon HSI V.35 Modem Cable
BC09W
Description:
A modem cable designed to connect the DS206-CA Eicon PC X.25
Network Controller to a V.35 modem.
Specification:
Connectors 26-way male D-type connector at the DS206 controller
end, 34-way male
D-type connector at the V.35 end. Both connectors are secured
with screw fixings.
Ordering Information BC09W-10.
BC09X Eicon HSI X.21 Modem Cable
BC09X
Description:
A modem cable designed to connect the DS206-CA Eicon PC X.25
Network Controller to an X.21 leased line.
Specification:
Connectors 26-way male D-type connector at the DS206 controller
end, 15-way male
D-type connector at the X.21 end.
Both connectors are secured with screw fixings.
Ordering Information BC09X-10.
BC12F DECbrouter 90 X.21 Adapter Cable
Description:
A 6 feet long cable designed to connect the DECbrouter 90 to a
X.21 leased line.
Specification:
Connectors Connector 1 50-way, straight, micro-champ (DECbrouter end),
Connector 2 15-way, straight, male, D-type (X.21 end).
Wiring:
Connector 1 (50-way) pin Connector 2 (15 way) pin Signal Name
1,2,26 - Code Ground *
-------------------------------------------------------------------
5 2 T(A) Tx Data A
30 9 T(B) Tx Data B
-------------------------------------------------------------------
6 5 I(A) DCD A
31 12 I(B) DCD B **
-------------------------------------------------------------------
8 3 C(A) RTS A
33 10 C(B) RTS B
-------------------------------------------------------------------
10 4 R(A) Rx Data A
35 11 R(B) Rx Data B **
-------------------------------------------------------------------
17 6 S(A) Tx Clock A
42 13 S(B) Tx Clock B **
-------------------------------------------------------------------
13,15 - Rx Clock A
DTE Clock A *
-------------------------------------------------------------------
38,40 - Rx Clock B
DTE Clock B *
-------------------------------------------------------------------
37 8 G DTE Ground
-------------------------------------------------------------------
where * indicates contacts are tied together (at Connector 1).
** indicates a 120 Ohm resistor is connected between pins
6-31, and 10-35, and 17-42; the resistors are located at
Connector 1.
Ordering Information:
BC12F-06 (17-03580-01)
BC12G DECbrouter 90 V.35 Adapter Cable
Description:
A 6 feet long cable designed to connect the DECbrouter 90 to a
V.35 modem.
Specification:
Connectors:
Connector 1 50-way, straight, micro-champ (DECbrouter end),
Connector 2 34-way, straight, male, V.35 square (V.35 end).
Wiring
Connector 1 (50-way) pin Connector 2 (34-way) pin Signal Name
1,26 - Code Ground *
4 E DSR A
------------------------------------------------------------------------
6 F DCD/I A
------------------------------------------------------------------------
9 D CTS A
------------------------------------------------------------------------
11 J Ring Indicate
------------------------------------------------------------------------
21 Y Tx Clock A
46 A Tx Clock B
-------------------------------------------------------------------------
22 U Clock A
47 W Clock B
--------------------------------------------------------------------------
23 R Rx Data A
48 T Rx Data B
--------------------------------------------------------------------------
24 P Tx Data A
49 S Tx Data B
-------------------------------------------------------------------------
25 V Rx Clock A
50 X Rx Clock B
-------------------------------------------------------------------------
32 C RTS
-------------------------------------------------------------------------
12,29 B DTE Ground *
------------------------------------------------------------------------
44 H DTR
------------------------------------------------------------------------
20 K Local Loop
------------------------------------------------------------------------
where * indicates contacts are tied together.
Ordering Information:
BC12G-06 (17-03766-01).
BC12H DECbrouter 90 RS422 Adapter Cable
Description:
A 6 feet long cable designed to connect the DECbrouter 90 to an
RS422 modem.
Specification:
Connectors:
Connector 1 50-way, straight, micro-champ (DECbrouter end),
Connector 2 37-way, straight, male, D-type (RS422 end).
Wiring
Connector 1 (50-way) pin Connector 2 (37-way) pin Signal Name
1,27 - Code Ground *
---------------------------------------------------------------------------------
4 11 DSR A
29 29 DSR B
----------------------------------------------------------------------------------
5 4 Tx Data A
30 22 Tx Data B
---------------------------------------------------------------------------------
6 13 DCD/I A
31 31 DCD/I B
---------------------------------------------------------------------------------
8 7 RTS/C A
33 25 RTS/C B
---------------------------------------------------------------------------------
9 9 CTS A
34 27 CTS B
---------------------------------------------------------------------------------
10 6 Rx Data A
35 24 Rx Data B **
----------------------------------------------------------------------------------
11 15 RI
---------------------------------------------------------------------------------
12 20 DCE Ground
---------------------------------------------------------------------------------
13 8 Rx Clock A
38 26 Rx Clock B **
---------------------------------------------------------------------------------
37 37, 19 DTE Ground *
---------------------------------------------------------------------------------
14 12 DTR A
39 30 DTR B
---------------------------------------------------------------------------------
15 17 Clock A
40 35 Clock B
---------------------------------------------------------------------------------
17 5 Tx Clock A
42 23 Tx Clock B *
---------------------------------------------------------------------------------
18 18 Test Indicate
---------------------------------------------------------------------------------
20 10 Local Loop
---------------------------------------------------------------------------------
41 16 Speed select
---------------------------------------------------------------------------------
45 14 Remote Loop
---------------------------------------------------------------------------------
where * indicates contacts are tied together.
** indicates a 120 Ohm resistor is connected between pins 13-38,
and 10-35, and 17-42; the resistors are located at Connector 1.
Ordering Information:
BC12H-06 (17-03767-01).
BC12J DECbrouter 90 EIA 530A Adapter Cable
Description:
A 6 feet long cable designed to connect the DECbrouter 90 to EIA
530A.
Specification:
Connectors:
Connector 1 50-way, straight, micro-champ (DECbrouter end),
Connector 2 25-way, straight, male, D-type (RS530A end).
Wiring
Connector 1 (50-way) pin Connector 2 (25-way) pin Signal Name
1,26,27 - Code Ground *
---------------------------------------------------------------------------------
4 6 DSR A
---------------------------------------------------------------------------------
5 2 Tx Data A
30 14 Tx Data B
---------------------------------------------------------------------------------
6 8 DCD/I A
31 10 DCD/I B
---------------------------------------------------------------------------------
8 4 RTS/C A
33 19 RTS/C B
---------------------------------------------------------------------------------
9 5 CTS A
34 13 CTS B
---------------------------------------------------------------------------------
10 3 Rx Data A
35 16 Rx Data B **
---------------------------------------------------------------------------------
11 22 RI
---------------------------------------------------------------------------------
12 23 DCE Ground
---------------------------------------------------------------------------------
13 17 Rx Clock A
38 9 Rx Clock B **
----------------------------------------------------------------------------------
29,37 7 DTE Ground *
---------------------------------------------------------------------------------
44 20 DTR
---------------------------------------------------------------------------------
15 24 Clock A
40 11 Clock B
---------------------------------------------------------------------------------
17 15 Tx Clock A
42 12 Tx Clock B **
---------------------------------------------------------------------------------
18 25 Test Indicate
---------------------------------------------------------------------------------
20 18 Local Loop
---------------------------------------------------------------------------------
41 16 Speed select
---------------------------------------------------------------------------------
45 21 Remote Loop
---------------------------------------------------------------------------------
where * indicates contacts are tied together.
** indicates a 120 Ohm resistor is connected between pins 13-38,
and 10-35, and 17-42; the resistors are located at Connector 1.
Ordering Information:
BC12J-06 (17-03760-01).
BC12K DECbrouter 90 RS423 Adapter Cable
BC12K
Description:
A 6 feet long cable designed to connect the DECbrouter 90 to an
RS423 modem.
Specification:
Connectors
Connector 1 50-way, straight, micro-champ (DECbrouter end),
Connector 2 37-way, straight, male, D-type (RS423 end).
Wiring
Connector 1 (50-way) Connector 2 (37-way) Signal Name
pin pin
1,2,27 - Code Ground *
---------------------------------------------------------------------
4 11 DSR A
29 29 DSR B
---------------------------------------------------------------------
7 4 Tx Data
---------------------------------------------------------------------
6 13 DCD/I A
31 31 DCD/I B
---------------------------------------------------------------------
32 7 RTS/C
---------------------------------------------------------------------
9 9 CTS A
34 27 CTS B
---------------------------------------------------------------------
10 6 Rx Data A
35 24 Rx Data B
---------------------------------------------------------------------
11 15 RI
---------------------------------------------------------------------
12 20 DCE Ground
---------------------------------------------------------------------
13 8 Rx Clock A
38 26 Rx Clock B
----------------------------------------------------------------------
37 19,22,25,30,35,37 DTE Ground *
---------------------------------------------------------------------
44 12 DTR
---------------------------------------------------------------------
17 5 Tx Clock A
42 23 Tx Clock B
---------------------------------------------------------------------
18 18 Test Indicate
---------------------------------------------------------------------
20 10 Local Loop
---------------------------------------------------------------------
41 16 Speed select
---------------------------------------------------------------------
45 14 Remote Loop
---------------------------------------------------------------------
19 17 Clock
----------------------------------------------------------------------
where * indicates contacts are tied together.
Ordering Information:
BC12K-06 (17-03761-01).
BC12K
BC12L DECbrouter 90 RS232 Adapter Cable
Description:
A 6 feet long cable designed to connect the DECbrouter 90 to an
RS232 modem.
Specification:
Connectors:
Connector 1 50-way, straight, micro-champ (DECbrouter end),
Connector 2 25-way, straight, male, D-type (RS232 end).
Wiring
Connector 1 (50-way) pin Connector 2 (25-way) pin Signal Name
1,2 - Code Ground *
------------------------------------------------------------------------------
4 6 DSR A
------------------------------------------------------------------------------
6 8 DCD/I A
-------------------------------------------------------------------------------
7 2 Tx Data
------------------------------------------------------------------------------
9 5 CTS A
------------------------------------------------------------------------------
10 3 Rx Data A
------------------------------------------------------------------------------
11 22 Ring Indicate
------------------------------------------------------------------------------
13 17 Rx Clock A
------------------------------------------------------------------------------
17 15 Tx Clock A
------------------------------------------------------------------------------
18 25 Test Indicate
------------------------------------------------------------------------------
19 24 Clock
------------------------------------------------------------------------------
20 18 Local Loop
------------------------------------------------------------------------------
32 4 RTS
------------------------------------------------------------------------------
12,29,31,34,35,37,38,42 7 DTE Ground *
------------------------------------------------------------------------------
41 23 Speed Select
------------------------------------------------------------------------------
44 20 DTR
------------------------------------------------------------------------------
45 21 Remote Loop
------------------------------------------------------------------------------
where * indicates contacts tied together.
Ordering Information:
BC12L-06 (17-03762-01).
BC12N MemoryChannel Link Cable
Description 10 feet long MemoryChannel link cable.
Specification
Number of Conductors 100 conductors in 50 twisted-pairs.
Connectors Connector 1 : 100-way (50 x 2, dual inline pins),
Male, D-type connector, with thumb-screws.
Connector 2 : 100-way (50 x 2, dual inline pins), Male, D-type
connectors, with thumb-screws.
Typical Usage For connecting PCI-MC adaptor to PCI-MC adaptor
For connecting PCI-MC adaptor to MC-Hub
Ordering Information BC12N-10, p/n 17-04091-01
BC12N
BC13L Video Cable for Color Monitor
BC13L
Description Color Monitor cable 10 feet long.
Number of Conductors The cable terminates in five co-axial
conductors, Colored red, green, blue, white and black.
Connectors 15-way, male, D-type, straight connector with
three rows of pins, with fixing screws at the system end, and
a BNC male connector at each of the five co-axial conductors at
the monitor end. Each BNC connector is embossed with a R, G, B,
H or V symbol, and is crimped onto the red, green, blue, white
and black coductors respectively.
Typical Usage To connect a Color monitor to the Alpha
range of servers and workstations.
Ordering Information BC13L-10 (30-34761-03)
BC13M Keyboard / Mouse Extender Cable
BC13M
Description:
A 10 feet long cable to connect the mouse and the keyboard to
specified workstations. It is supplied with the DECstation 5000
Model 240, and 1xx series machines, as the interconnect for the
mouse and keyboard, and it may be purchased as an optional extra
for the VAXstation 4000 models 60 and 90 to extend the mouse and
keyboard cabling length.
Specification:
Connectors 15-way D-type female connector with screw fixings at
the system box end: a junction box with a round 7-way mouse socket
and an RJ12 4-way keyboard connector, at the mouse/keyboard end.
Ordering Information:
BC13M-10 (17-02640-01).
BC16C, BC16D DEC423 "Harmonica"
Cables
BC16C
Description:
The BC16C and BC16D cables are used in conjunction with the H3104
Cable Concentrator (Harmonica).
Specification:
PVC shielded, 1.5cm diameter.
Number Of Conductors 36, consisting of 18 twisted pairs.
Connectors BC16C - one right-angle 36-way centronics style connector,
and one straight 36-way centronics connector.
BC16D - two right-angle 36-way centronics style connectors.
Wiring Pin to pin.
Pin Signal Pin Signal
1 Line 0 Tx+ 19 Line 0 Tx-
2 Line 0 Rx+ 20 Line 0 Rx-
3 Line 1 Tx+ 21 Line 0 Tx-
4 Line 1 Rx+ 22 Line 1 Rx-
etc etc
15 Line 7 Tx+ 33 Line 7 Tx-
16 Line 7 Rx+ 34 Line 7 Rx-
17 Spare 35 Spare
18 Spare 36 Spare
Typical Usage To connect DECservers and communications controllers
to the H3104 Cable Concentrator in order to provide eight DEC423
MMJ connectors.
NOTE : For DECserver 300 users, the BC16C/D cables will allow
data-leads-only connections; it is NOT adequate when users want
to utilise DSR/DTR connections which enable the DECserver 300
Autologout feature.
NOTE : To join two lengths of BC16C/D cables together the H3102-00
cable coupler may be used.
Ordering Information:
For both BC16C and BC16D :
E0-BC16C-10, -25, -50, -A0 (100ft), -B5 (250ft).
NOTE : The H3104-B adapter kit consists of a BC16C-10
cable, plus an H3104 Cable Concentrator. Two cable concentrator
packages (P/N : 70-24313-01) containing a BC16D-25 and an H3104,
are supplied with the CXA16 and CXB16 communication controllers.
BC16E DEC423 Office Cable
BC16E
Description:
Terminal inconnection cable for use with DEC423 terminals and
printers in an office environment. It is configured as a null-modem
cable.
Specification:
Unshielded, flat, PVC insulation.
Number Of Conductors 6 conductors in a flat ribbon cable.
Connectors Two standard DEC423 Modified Modular
MMJ Connector
Plugs (MMPs). 6 pin connectors with offset lug.
Wiring Null modem.
Pin (Signal) To Pin (Signal)
1 DTR - 6 DSR
2 TD+ - 5 RD+
3 TD- - 4 RD-
4 RD- - 3 TD-
5 RD+ - 2 TD+
6 DSR - 1 DTR
Where :
TD+ is Transmitted Data
TD- is Transmitted Data Return
RD+ is Received Data
RD- is Received Data Return
Typical Usage: To connect DEC423 terminals and printers,
and also EIA-232 (data lines only) devices with use of the appropriate
H8571-x passive adapter.
Hardware:
Use the H8572 6-conductor cable extender to join BC16E cables
together. To custom build BC16E cables to a desired length, use;
H8240 DEC423 Office Cable (305 metre spool), and, H8220 Modified
Modular Plugs (pack of 50), using the H8241 Crimp Tool to terminate
the cable.
Ordering Information:
E0-BC16E-02, -10, -25, -50.
BC16K ThinWire Patching Cable
Description:
Length of RG58 ThinWire Ethernet cable for use as a patch cord
in a Satellite Equipment Room (SER).
Specification:
Number Of Conductors: One co-axial.
Connectors: Male BNC style connector at each end.
Typical Usage:
There are 16 BC16K cables supplied with the H3118 ThinWire Patch
Cord Kit, which is used in conjunction with the H3107-B ThinWire
Patch Block.
Ordering Information:
E0-BC16K-02
BC16M ThinWire Cable
BC16M
Description:
ThinWire co-axial cable for use with devices which have ThinWire
BNC connectors. The maximum length of a ThinWire Ethernet segment
is 185m.
Specification:
The pre-terminated BC16M cable has PVC insulation, but lengths
of BC16M cable can be manufactured using either PVC or Teflon
insulated cable.
Beldon 9907 for PVC, Beldon 89907 for Teflon. For IEEE 802.3.
10 Base 2, 10 Mb/s. Impedance: 50 ohms 20 AWG. Diameter 0.46cm.
Minimum bending radius 4 cm.
Number Of Conductors:
One double screened co-axial conductor with foamed dielectric.
Connectors:
Two male BNC style connectors
Hardware:
Cables can be manufactured from lengths of H8243-A (PVC), or H8244-A
(teflon) Thin Wire Cable on 305m spool, and E0-H8222 Co-axial
connectors using the H8242 tool kit which contains the necessary
crimping tool and strippers.
To correctly terminate a ThinWire segment use a E0-H8225 ThinWire
Terminator. To connect a node to a ThinWire segment use a
E0-H8223-00 'T' Connector. To join two BC16M cables together,
use a E0-H8224 Barrel Connector.
Ordering Information:
E0-BC16M-06, E0-BC16M-15,
E0-BC16M-30
BC19B EIA-422 Adapter Cable
BC19B
Description:
EIA-422 synchronous adapter cable. To adapt Digital's 50 pin synchronous
connector to EIA-422.
Specification:
Number Of Conductors: 28.
Connectors: One 50 way D-type female, and one 37 way D-type
male.
Wiring:
50-Way Signal 37-Way 50-Way Signal 37-Way
Pin Name Pin Pin Name Pin
1 CODE GROUND * 20 Tx CLOCK (A) 5
4 CODE 2 * 21 TX CLOCK (B) 23
6 Tx DATA (A) 4 34 DSR (A) 11
7 Tx DATA (B) 22 35 DSR (B) 29
9 RTS/C (A) 7 37 DCD/I (A) 13
10 RTS/C (B) 25 38 DCD/I (B) 31
11 Rx DATA (A) 6 39 CTS (A) 9
12 Rx DATA (B) 24 40 CTS (B) 27
13 LOCAL LOOP 10 41 DCE GROUND 20
15 TEST 1 18 44 DTE GROUND 19, 37
16 REM.LOOP 14 45 DTR (A) 12
17 RI 15 46 DTR (B) 30
18 Rx CLOCK (A) 8 47 CLOCK (A) 17
19 Rx CLOCK (B) 26 48 CLOCK (B) 35
50 SPEED 16
Where, * means the pins are connected together, and (A), (B) are
A(+ve) and B(-ve) wires of a twisted pair.
Typical Usage:
DMB32, DEMSA, DSV11 connections for EIA-422. Use the BC55D extension
cable for this adapter.
Ordering Information:
E0-BC19B-02 (17-01108-01).
BC19C X.21 Adapter Cable
BC19C
Description:
Synchronous adapter cable to adapt Digital's standard 50-way synchronous
connector to X.21, or BT's Kilostream.
Specification:
Number Of Conductors
Connectors One 50-way female, and one 15-way male connector.
Wiring
50-Way 15-Way Signal
1, 2, 3 - Code Ground
6 2 Tx Data A
7 9 Tx Data B
9 3 Control A
10 10 Control B
11 4 Rx Data A
12 11 Rx Data B
18 7 Byte Timing A
19 14 Byte Timing B
20 6 Signal Timing A
21 13 Signal Timing B
37 5 Indication A
38 12 Indication B
44 8 DTE Ground
Shell Shell Shield Braid and Drain Wire
Note : 0.5 W, 120 Ohm resistor between pins :
11 and 12, 18 and 19, 20 and 21, 37 and 38.
Typical Usage To connect a synchronous controller such
as the DMB32. or DSB32 to X.21. Use the BC22Z to extend this cable.
IMPORTANT NOTE : The BC19C adapter cable may not be compatible
with early BT Kilostream Network Terminating Units (NTU).
When an older NTU is being used, the BC22X Kilostream adapter
cable may be needed. Check with your telecom provider to determine
the correct cable to use, quoting the cables' pinouts.
Ordering Information:
BC19C-02
BC19D V.24 Adapter Cable
BC19D
Description:
Synchronous adapter cable to adapt Digital's standard 50-way synchronous
connector to V.24.
Specification:
This cable is a component part BS19D-02 V.24 synchronous adapter
cable kit.
Number Of Conductors: 16.
Connectors: 50-way female D-type, 25-way male D-type.
Wiring
50-Way Pin Signal Name 25-Way Pin 50-Way Signal Name 25-Way Pin
1 CODE GROUND * 22 CLOCK 24
3 CODE 1 * 33 DTR 20
8 Tx DATA 2 34 DSR (A) 6
11 Rx DATA (A) 3 35 DSR (B) #
12 Rx DATA (B) # 36 RTS 4
13 LOCAL LOOP 18 37 DCD/I (A) 8
15 TEST 1 25 38 DCD/I (B) #
17 RI 22 39 CTS (A) 5
16 REM. LOOP 21 40 CTS (B) #
18 Rx CLOCK (A) 17 41 DCE GROUND #
19 Rx CLOCK (B) # 44 DTE GROUND 7,#
20 Tx CLOCK (A) 15 50 SPEED 23
21 Tx CLOCK (B) #
Where:
* means the pins are connected together,
# means connected to DCE ground, and,
(A), (B) are A(+ve) and B(-ve) wires of a twisted pair.
Typical Usage
To connect a synchronous controller such as the DEMSA, DMB32,
DSV11, etc for V.24 use. Use with the BC22F extender cable.
Ordering Information
The BC19D-02 is a component part of E0-BS19D-02 which may be ordered.
BC19E EIA-423 Adapter Cable
BC19E
Description:
Adapter cable to adapt Digital's 50-way synchronous connector
to EIA-423.
Specification:
Number Of Conductors: 24. 12 singles, 6 twisted pairs plus
drain wire.
Connectors: One 50-way D-type female, one 37-way male D-type.
Wiring:
50-Way Pin Signal Name 37-Way Pin 50-Way Pin Signal Name 37-Way Pin
1 CODE GROUND *
3 CODE 1 *
8 Tx DATA 4 34 DSR (A) 11
11 Rx DATA (A) 6 35 DSR (B) 29
12 Rx DATA (B) 24 36 RTS 7
13 LOCAL LOOP 10 37 DCD/I(A) 23
15 TEST 1 18 38 DCD/I (B) 32
16 REM.LOOP 14 39 CTS (A) 9
17 RI 15 40 CTS (B) 27
18 Rx CLOCK (A) 8 41 DCE GROUND 20
19 Rx CLOCK (B) 26 50 SPEED 16
20 Tx CLOCK (A) 5 44 DTE GROUNDS 19
21 Tx CLOCK (B) 23 22
22 CLOCK 17 25
33 DTR 12 30
35
37
Where, * means the pins are connected together, and (A), (B) are
the A(+ve), and B(-ve) wires of a twisted pair.
Typical Usage:
To connect a synchronous controller for EIA-423. Use with a BC55D
extender cable.
Ordering Information:
BC19E-02.
BC19F V.35 Adapter Cable
BC19F
Description:
Synchronous adapter cable to adapt Digital's 50-pin sychronous
connnector to V.35.
Specification:
Number of conductors: 17.
Connectors: One 50-way D-type female, one 34-way rectangular
V.35 type male.
Wiring:
50-Way Pin Signal Name 34-Way Pin 50-Way Pin Signal Name 34-Way Pin
1 CODE GROUND * 31 V.35 Rx CLOCK (A) V
2 CODE 0 * 32 V.32 Rx CLOCK (B) X
17 RI J 33 DTR H
23 V.35 Tx CLOCK (A) Y 34 DSR (A) E
24 V.35 Tx CLOCK (B) A 35 DSR (B) #
25 V.35 CLOCK (A) U 36 RTS C
26 V.35 CLOCK (B) W 37 DCD/I (A) F
27 V.35 Rx DATA (A) R 38 DCD/I (B) #
28 V.35 Rx DATA (B) T 39 CTS (A) D
29 V.35 Tx DATA (A) P 40 CTS (B) #
30 V.35 Tx DATA (B) S 41 DCE GROUND #
44 DTE GROUND B, #
Where:
* means the pins are connected together
# means connected to DCE GROUND
(A), (B) wires are a(+ve), and b(-ve) of a twisted pair.
Typical Usage:
to connect a synchronous controller such as the DEMSA, DMB32,
DSV11, ect for the V.35 use. Use with the BC19L extender cable.
Ordering Information:
E0-BC19F-02 (17-01112-01).
BC19J SCSI Cable
BC19J
Description:
Single-ended SCSI cable.
Specification:
Number Of Conductors 50 in 25 twisted pairs, plus screening.
Connectors Two 50-way, low-density, centronics style, straight
connectors.
Typical Usage To daisy-chain SCSI devices.
Ordering Information:
The BC19J-1E, and the BC56H-03 are generally supplied with non-embedded
SCSI devices.
The BC19J-1E is not available as a separate item.
BC19J-1E (1 foot 6 inches), BC19J-03, BC19J-06. (17-01351-04,
17-03151-01, 17-03151-02).
BC19L V.35 Communications Cable
Description:
V.35 extension (modem) cable.
Specifications:
Number Of Conductors: 13.
Connectors: One 34-way male, one 34-way female.
Wiring: Straight through.
Typical Usage: Extension for the BC19F V.35 adapter cable.
Ordering Information:
BC19L-25.
BC19M IBM PC Parallel Interface Cable
BC19M
Description: This cable is designed to connect a Centronics
type parallel printer to the parallel printer port of an IBM or
IBM compatible PC.
Specification:
Shielded.
Number Of Conductors: 25
Connectors: 25-pin male D-type at PC end, 36-way male Centronics
type at printer end. Both ends are straight.
Wiring:
25-way PC end. Signal 36-way Printer end.
1 Strobe to printer 1
2 Data Bit 1 - to printer 2
3 Data Bit 2 - to printer 3
4 Data Bit 3 - to printer 4
5 Data Bit 4 - to printer 5
6 Data Bit 5 - to printer 6
7 Data Bit 6 - to printer 7
8 Data Bit 7 - to printer 8
9 Data Bit 8 - to printer 9
10 Acknowledge Low - from printer 10
11 Busy High - from printer 11
12 Paper End High - from printer 12
13 Error Low - from printer 13
14 Auto Feed Low - to printer 14
15 NOT USED 32
16 Initialise Low - to printer 31
17 Select Input Low 36
18 Ground 33
19 Ground 19
20 Ground 21
21 Ground 23
22 Ground 25
23 Ground 27
24 Ground 29
25 Ground 30
Ordering Information:
BC19M-10 (17-01516-01).
BC19M-06 (17-01516-02)
BC19N EIA-232 "One-To-Four" Cable
Description: Adapter cable assembly to provide four EIA-232
connections from a single outlet.
Specification:
Number Of Conductors 44
Connectors One 50-way male centronics style connector to
four 25-way D-type male connectors.
Wiring The pin-outs for the 50-way connector are as follows
:
Pins 1-11 are Channel 0
Pins 13-23 are Channel 1
Pins 25-35 are Channel 2
Pins 27-47 are Channel 3
Pins 12, 24, 36, 48, 49, and 50 are not used.
Signal 50-Way Pins 25-Way Pins
Transmitted Data 1 13 25 37 2
Received Data 2 14 26 38 3
Request To Send 3 15 27 39 4
Clear To Send 4 16 28 40 5
Data Set Ready 5 17 29 41 6
Signal Ground 6 18 30 42 7
Data Carrier Detected 7 19 31 43 8
(Not Used) 8 20 32 44 12
Data Terminal Ready 9 21 33 45 20
Ring Indicator 10 22 34 46 22
(Not Used) 11 23 35 47 25
Typical Usage:
Two BC19N cable assemblies are supplied with the CXY08 Communications
Controller to enable the connection of the eight EIA-232 modem
channels.
Ordering Information:
Not available as separate items.Two BC19N-12 (17-01399-01) cables
are provided in the Cable Concentrator Package (70-24314-01) supplied
with the CXY08 controller.
BC19S Cable for Color Monitor
BC19S
Description:
VAXstation 3100 Color monitor cable, 10 feet long.
Specification:
15-way D-type, female connector with fixing screws at the system
end, and connector block with screw fixing at the monitor end.
The connector block has the following connectors:
* three BNC male connectors, on short leads, for the monitor.
* 4-way keyboard socket.
* 7-way socket for the mouse.
The 3 BNC connectors are embossed with the legend 'R', 'G', or
'B', and the short leads to which they are attached are Color
coded red, green, or blue.
Typical Usage:
Used with VAXstation 3100 models 30, 38, 48 (Color - not SPX).
Also used with the VAXstation 2000 (Color).
Ordering Information:
BC19S-10 p/n 17-01480-01
BC19Y EIA-422 Null Modem Cable
BC19Y
Description
The BC19Y is an EIA-422 Null Modem unit interconnect cable.
Specification
Connectors Two 50-way female D-type connectors.
Wiring Null modem.
Typical Usage To connect MUXserver 300 to DECmux 300, or,
connects two DECmux 300s together.
Ordering Information BC19Y-10
BC21G BT Kilostream Adapter Cable
BC21G
Description
RS422 to BT Kilostream adapter cable, designed for connection
between the DNSXH-AC RS422 distribution panel of the DECNIS WANcontroller
318 (also used with the DE206-AA EtherWORKS Router) and BT Kilostream
in the UK.
Specification
Number Of Conductors
Connectors One 37-way female D-type at the WANcontroller
end, and one 15-way male D-type at Kilostreams NTU end.
Wiring
37-way Signal 15-way
(Pin) (Pin)
4 Tx Data A 2
22 Tx Data B 9
7,9 Control A 3
25,27 Control B 10
6 Rx Data A 4
24 Rx Data B 11
8,5 Signal Timing A 6
26,23 Signal Timing B 13
13 Indication A 5
31 Indication B 12
19,37 DTE Ground 8
11,12 DSR A to DTR A
29,30 DSR B to DTR B
10,18 Local Loop to Test Indicate
15,16 DSRs to RI
SHELL Shield Braid SHELL
Note : i) There is a 120 Ohm resistor between the following pins,
at the 37-way connector :
6 and 24 - Rx Data
5 and 23 - Signal Timing
13 and 31 - Indication
Typical Usage
Connects an RS422 port of the DNSXH-AC distribution panel of the
DECNIS WANcontroller 618, and also the EtherWORKS Router to BTs
Kilostream.
Use the BC19C-02 to connect the DECNIS WANcontoller 622 to Kilostream.
Ordering Information BC21G-02 (17-03100-01)
BC21M DSSI Cable
BC21M
Description:
DSSI cable for inter-cabinet use.
Specification:
Connectors Two right-angled, female 50 way PS (Pedestal
or Pin Socket) connectors with screw fixings.
Ordering Information BC21M-03, -09, -16, -25 (feet). (17-02152-01,
-03, -04, -05).
BC21Q DSSI Cable
BC21Q
Description DSSI cable for inter-cabinet use.
Specification
Connectors Two MR (Mid-Range) style, female, straight,
50-way connectors with screw fixings.
Typical Usage Connects VAX 6000, 7000, 9000, and 10000
systems to DSSI storage cabinets.
Ordering Information BC21Q-3F (3.5 feet), -06, -09, -25,
-50 (feet) (17-02382-01, -09, -02, -05, -06, -10.)
The BC21Q-09 is a component part of both the CK-SF100-LM, and
CK-SF200-LM cable kits. Also BC21Q-16 and BC21Q-25 are component
parts of different variants of these kits.
BC22D Terminal Cable
BC22D
Description
The BC22D is a fully shielded, EIA-232 null modem cable designed
for asynchronous applications.
Specification
Gauge: 24-AWG;
Shield: 36-AWG braid.
Number Of Conductors 6
Connectors Two 25 way female D-type.
Wiring Null modem.
Pin Signal Pin Signal
1 1
2 Transmit Data 3 Receive Data
3 Receive Data 2 Transmit Data
6 DSR 20 DTR
7 Signal Ground 7 Signal Ground
20 DTR 6 DSR
Typical Usage To connect EIA-232 terminals and printers
to DECservers etc.
Ordering Information
E0-BC22D-10, E0-BC22D-25, E0-BC22D-50 E0-BC22D-A0, -B0, -B5.
BC22E EIA232 Modem Cable
Description
The BC22E is a fully shielded EIA-232 asynchronous modem cable.
Specification
Gauge: 24-AWG:
Shield: 36-AWG braid.
Number Of Conductors 16
Connectors One male and one female 25 way D-type.
Wiring Point to point for the following pins:
1, 2, 3, 4, 5, 6, 7, 8,
11, 12, 18, 19, 20, 22, 23, 25.
Typical Usage To connect to asynchronous modems, or to
extend a BC22D null modem cable.
Ordering Information
E0-BC22E-02, E0-BC22E-10, E0-BC22E-25, E0-BC22E-50, -A0, -B0,
-B5.
BC22F EIA232 Modem Cable
BC22F
Description
Fully shielded EIA-232 synchronous modem cable.
Specification
Gauge: 24-AWG;
Shield: 36-AWG.
Number Of Conductors 25
Connectors One male and one female 25 way D-type.
Wiring Point to point for all pins.
Typical Usage
For connection to synchronous modems, and as an extension for
a BC19D cable.
Ordering Information
E0-BC22F-10, -25, -50, -A0, -B0, -B5.
BC22H Gender Changer Cable
Description
This 24 inch cable is fully shielded and was designed for use
as a "gender changer".
Specification
Gauge: 24-AWG,
Shield: 36-AWG braid.
Number Of Conductors 25.
Connectors Two male 25 way D-type connectors, which are
not molded on.
Wiring Point to point for all 25 connectors.
Typical Usage To adapt a cable by changing its gender at
one end.
Ordering Information
BC22H-02
BC22R EIA-232 Null Modem (CTS/RTS) Cable
Description:
EIA-232 null modem cable designed for devices using CTS/RTS flow
control.
Specification Shielded.
Number Of Conductors 10
Connectors 25-way female connectors at each end.
Wiring
Signal Pin Pin
TD 2 3
RD 3 2
RTS 4 5
CTS 5 4
DTR 20 6,8
DSR, CD 8 20
RI 22 23
DSRS 23 22
Typical Usage
To connect host systems and devices using CTS/RTS flow control
to the DECmux 300 EIA-232 user port.
Note : Use a BC17D cable to connect host systems and devices
that do NOT use CTS/RTS flow control to the DECmux 300 EIA-232
user port.
Ordering Information BC22R-10, -25, -50, - A0.
BC22Q DSSI Cable
BC22Q
Description:
DSSI cable for inter-cabinet use.
Specification:
Connectors
One MR (Mid-Range) style, female, straight, 50-way connector with
screw fixings, one PS (Pin Socket) style, female, right-angled
connector, also with screw fittings.
Typical Usage Connects VAX 4000, and Q-bus MicroVAX 3000
series systems to DSSI storage cabinets.
Ordering Information BC22Q-09, -16, -25, -50 (feet). (17-0271-01,
-02, -03, -04).
The BC22Q-09 is not separately orderable.
The BC22Q-09 is a component part of both the CK-SF100-LP, and
the CK-SF200-LP cable kits, also the BC22Q-16, BC22Q-25, and BC22Q-50
are component parts of different variants of these kits.
BC22X UK Kilostream Adapter Cable
Description:
The BC22X is an adapter cable for adapting Digitals standard 50-way
synchronous connector to early versions of BT's Kilostream
network and Mercury Communications equivalent network when operating
at 64 Kb/s using the X.21 (15 pin D-type) connector.
For newer installations the BC19C adapter cable will be required,
see entry "BC19C". Check with your telecom provider
for correct cable choice.
Specification:
Number Of Conductors 7
Connectors One 50 pin female, and one 15 way male connector.
Wiring
50-Way Signal 15-Way
1,4 Code Ground (RS422) -
6 Tx Data A 2
7 Tx Data B 9
11 Rx Data A 4
12 Rx Data B 11
20 Signal Timing A 6
21 Signal Timing B 13
9,37,39 RTS A, DCD A, CTS A -
10,38,40 RTS B, DCD B, CTS B -
13,15 Local Loop, Test Ind -
50,17 Speed Sel Incoming Call -
34,45 RSD A, DTR A -
35,46 DSR B, DTR B -
44 DTE Ground, Drain Wire 8
Shell Shield Braid and Drain Wire Shell
Notes :
i)120 Ohm resistor between pins 11 and 12.
ii) One 120 Ohm resistor between pins 18 and 20 tied together,
and 19 and 21 are tied together.
Typical Usage For use with a synchronous controller,eg,
DEMSA, DMB32, etc . Use the BC22Z to extend the BC22X adapter.
Ordering Information
Order the BC22X-02 from the manufacturer:
BIEN Data,
Crowmarsh Gifford,
Oxfordshire.
TEL 0491 826030
BC22Z X.21 Communications Cable
Description:
A cable designed to extend the BC22X X.21 adapter cable.
Specification
Number Of Conductors 12, 6 twisted pairs.
Connectors One 15-way D-type male, one 15-way D-type female.
Typical Usage Use as an extender cable for the BC22X X.21
adapter cable.
Ordering Information
Order from BIEN Data (See BC22X entry for address).
BC23J Video Cable for Color Monitor
BC23J
Description:
VAXstation 3100 Color monitor cable, 30 inches long.
Specification:
Connectors: 15-way D-type female connector with screw fixings
at the system end, and a connector block with 3 BNC co-axial connectors
each attcahed via a short lead on the monitor end.
Each BNC connector has a 'R', or 'G', or 'B' embossed legend to
indicate correct connection.
Typical Usage: To connect the monitor to a VAXstation 3100
Color model (including SPX option), or to a DECstation 3100 Color
model.
Ordering Information:
BC23J-03 p/n 17-01992-01
BC23P DEC423 "Octopus" Cable
BC23P
Description A ten foot "Octopus" cable assembly
to convert 8 DECconnect Modified Modular Jack (MMJ) outputs to
one 36-way connection suitable for connection to an H3104 Cable
Concentrator.
Specification Unshielded.
Number Of Conductors 36 (18 twisted pairs) on single cable
part, 6 on each MMP terminated cable part.
Connectors 8 Modified Modular Plugs (MMPs) on one end of
the cable, each one being numbered, and one 36-way centronics
style connector on the other end.
Typical Usage For use with the DECserver 300. The use of
two BC23P cables enables two H3104s to be connected to a DECserver
300 for the purpose of patching in a Satellite Equipment Room.
N.B. : As this "octopus" cable has only 36 conductors,
it is NOT suitable for customers wishing to utilise the DTR/DSR
facilities offered by the DECserver 300, it can accommodate only
the transmit and receive data.
Ordering Information E0-BC23P-10.
Two of these cables are needed for each DECserver 300, and they
need to be ordered as an optional extra.
BC25R Internal SCSI Cable
Description Internal 8-bit SCSI cable used on the AlphaServer
2100 systems to connect a narrow, or 8 bit, SCSI controller to
the internal storage shelf. This is a ribbon cable approximately
1.2m long, with a large ferrite bead at the halfway point.
Connectors Two 50-way, female, keyed IDC Ribbon Cable Connector
sockets (Berg connectors) crimped onto a 50-conductor flat , ribbon
cable.
Ordering Information BC25R-3B (17-03948-01)
BC25T Internal SCSI Cable
BC25T
Description Internal 16-bit SCSI cable used on the AlphaServer
2100 systems to connect a wide, or 16-bit, SCSI controller to
the internal storage shelf. This is a ribbon cable approximately
1.2m long, with a large ferrite bead at the halfway point.
Connectors Two 68-way, male, IDC ribbon cable connectors
crimped onto a flat ribbon cable.
Ordering Information BC25T-3L (17-04180-01)
BC25U Internal SCSI Cable
Description
Internal 16-bit SCSI cable used on AlphaServer 2000 systems to
connect a wide, or 16-bit, SCSI controller to the internal storage
shelf. This is a ribbon cable approximately 0.8m long.
Connectors Two 68-way, male, IDC ribbon cable connectors
crimped onto a flat ribbon cable.
Ordering Information BC25U-2H (17-04088-01)
BC27A Line Printer Cable
BC27A
Description This cable is designed to connect a line printer
to any Data Products protocol parallel port other than the LPV11-SA
Specification Shielded.
Number Of Conductors 25
Connectors 37-pin male D-type at controller end, 50-pin
male D-type at printer end.
Wiring
50-Pin End (Printer) Signal 37-Pin End (Controller)
19 Data Bit 1 26
3/35 Return 30
20 Data Bit 2 20
4/42 Return 34
1 Data Bit 3 22
2/14 Return 28
41 Data Bit 4 1
40 Return 33
34 Data Bit 5 24
18/37 Return 35
43 Data Bit 6 23
42 Return 34
36 Data Bit 7 5
35 Return 30
30/28 Paper Instruction 6
23 Demand 18
7/40 Return 33
38 Data Strobe 8
37 Return 35
21 On Line 12
5/45 Return 32
46 Interface Verify 14
45 Return 32
26 VFU Ready 17
10 Return 31
Typical Usage Connects the LP11, LPV11, DMB32 DECserver
250, parallel controller ports to LP25, LP26, LP27, LP29, LP37,
LG01, and LG02. Use the BC27L cable when connecting a line printer
to an LPV11-SA (BA200 series cabinet dual port) controller.When
connecting a line printer directly to an LP11 module, ie to the
actual printed circuit board, use the 70-16560-30 cable.
Ordering Information BC27A-30, BC27A-50.
BC27M Monochrome Monitor Cable
Description: Monochrome monitor cable, 3 feet long.
Specification:
Connectors: D-type connector with 3 co-axial sockets, with fixing
screws at the system end, and a BNC co-axial connector at the
monitor end.
Typical Usage: To connect the monitor to the monochrome
DECstation 5000 models 20, 25, 33.
Ordering Information:
BC29M-03
p/n 17-03399-01
BC27Z RapidPrint 200 to Dataproduct Line
Printer Cable.
Description Cable designed to connect a Datapoducts interface
line printer to a RapidPrint 200 Universal Network Printer Interface.
Specification
Connectors: Connector 1 - 25-way, male, D-type at the RapidPrint
end, Connector 2 - 50-way, male, D-type at the printer end.
Typical Usage To connect the Dataproduct interface of a
printer such as the LG06 or the LG12 to a network via the Rapidprint
200 (DSTPP-AE).
Ordering Information BC27Z-10, BC27Z-30 (17-04148-01, 17-04148-02).
BC29G Color Monitor Cable
BC29G
Description: Triax Color monitor cable 9 feet in length.
Specification:
Number of Conductors: 3.
Connectors: D-type connector with 3 co-axial sockets, with
fixing screws at the system end, and 3 BNC co-axial connectors
on short leads to a connector block at the Color monitor end.
The short leads at the monitor ends are Colored red, or green,
or blue.
Typical Usage: To connect the Color monitor to the following
systems:
VAXstation 4000 model VLC (except VRT13 based system)
VAXstation 4000 models 60 and 90.
DECstation 5000 models 100 and 200 series Color models.
Ordering Information:
BC29G-09
p/n 17-02906-01
The BC29G-09 is a 9 feet long version of the BC29H-2E cable.
BC29H Color Monitor Cable
BC29H
Description: Triax Color monitor cable with an overall length
of 3 feet.
Specification:
Number of Conductors: 3
Connectors: D-type connector with 3 co-axial sockets, with
fixing screws at the system end, and 3 BNC co-axial connectors
on short leads to a connector block at the Color monitor end.
The short leads at the monitor ends are Colored red, or green,
or blue.
Typical Usage: To connect the Color monitor to the Personal
DECstation 5000 models 20, 33, and 125.
Ordering Information:
BC29H-2E
p/n 17-02906-02
The BC29H-2E is a 3 feet long version of the BC29G-09 cable.
BC29P PC Modem Cable.
Description: Modem cable to connect the 9-way, male, serial
port of a PC to the 25-way, female, port of an RS232 Modem.
Specification:
Number of Conductors 9.
Connectors: One 9-way D-type female, one 25-way D-type
male.
Wiring: Straight-through.
Pin Pin Signal
1 8 DCD Received Line Signal Detect
2 3 Rx Received Data
3 2 Tx Transmitted Data
4 20 DTR Data Terminal Ready
5 7 SIG GND Signal Ground
6 6 DSR Data Set Ready (DCE Ready)
7 4 RTS Request To Send (Ready For Receiving)
8 5 CTS Clear To Send
9 22 RI Ring Indicator
Typical Usage:
1. To connect a PC to a modem.
2. To connect the 9-way OBM (Out-Of Band Management) serial port
of the DEChub 900 MultiSwitch, and also the OBM port of the DEChub
One docking station, to a modem.
Ordering Information:
BC29P-10.
p/n 17-03860-01.
This cable is available from
BIEN Data, Crowmarsh Gifford, Oxfordshire.
Tel 0491-826030
BC29Q PC Null Modem Cable.
Description: Null Modem cable to connect to the 9-way,
male, serial port of a PC.
Specification:
Number of Conductors 9.
Connectors: Two 9-way D-type female connectors.
Wiring: Null Modem (crossed).
Pin Signal Pin Signal
1 DCD Received Line Signal Detect 4 DTR
2 Rx Received Data 3 Tx
3 Tx Transmitted Data 2 Rx
4 DTR Data Terminal Ready 1 DCD
5 SIG GND Signal Ground 5 Sig Gnd
6 DSR Data Set Ready (DCE Ready) 4 DTR
7 RTS Request To Send (Ready For Receiving) 8 CTS
8 CTS Clear To Send 7 RTS
9 RI Ring Indicator Not connected
Typical Usage: To connect a PC to the 9-way OBM (Out-Of
Band Management) serial port of the DEChub 900 MultiSwitch, and
also the OBM port of the DEChub One docking station.
Ordering Information:
BC29Q-10.
p/n 17-03861-01.
This cable may also be available from BIEN Data, Crowmarsh Gifford,
Oxfordshire.
Tel 0491-826030
BC29R DSSI Cable for HSD.
Description: DSSI cable to connect the VAX/DEC 4000 system
to the HSD05 or HSD30 DSSI to SCSI adapter/controller.
Specification:
Connectors: One 50-way MR (micro-ribbon) right-angled connector
for the HSD, and one 50-way PS (pin socket or tab) right-angled
connector for the system end.
Ordering Information:
BC29R-06, -09, -16, -30, 45, -60.
p/n 17-03855-04, -05, -06, -07, -08, -09.
BC29S DSSI Cable for HSD.
Description DSSI cable to connect the VAX/DEC 6000/7000/10000
system to the HSD05 or HSD30 DSSI to SCSI adapter/controller.
Specification:
Connectors: One 50-way MR (micro-ribbon) right-angled connector
for the HSD, and one 50-way MR straight connector for the system
end.
Ordering Information
BC29S-06, -09, -16, -30, 45, -60.
p/n 17-03855-01, -02, -03, -10, -11, -12.
BC29T DSSI Cable for StorageWorks cabinet.
Description DSSI cable to interconnect two DSSI nodes,
such as HSD05s, from a horizontal shelf to a vertical shelf on
the same side of a StorageWorks Data Centre cabinet.
Specification:
Connectors: Two 50-way MR (micro-ribbon) right-angled connectors.
Both connectors are right-angled in the same direction.
Ordering Information
BC29T-03, -09.
p/n 17-03855-13, -14.
BC29U DSSI Cable for StorageWorks cabinet.
Description DSSI cable to interconnect two DSSI nodes,
such as HSD05s, which are housed on adjacent horizontal shelves
on the same side of a StorageWorks Data Centre cabinet.
Specification:
Connectors Two 50-way MR (micro-ribbon) right-angled connectors.
One connector is right-angled to the right, the other to the left.
Ordering Information:
BC29U-02.
p/n 17-03855-15
BC29V HSD30 link cable.
Description Link cable for HSD 10/30 Adapters/Controllers
Specification:
Connectors: Two MR (micro-ribbon) type, right-angled connectors.
Typical Usage:
- The one foot long cable, BC29V-01, is used to link two HSD30
controllers which are housed in the same BA350-MB controller shelf.
- The BC29V-06/16 is used to connect the HSD10 in one pedestal
to an HSD10 in a second pedestal.
Ordering Information:
BC29V-01
p/n 17-03855-17
BC42A Convenience Power Cable / Jumper Cable
BC42A
Description 30 inch long power convenience or jumper cable
used to "daisy-chain" AC power from one option to another
in a tidy manner.
Specification
Number Of Conductors Three.
Connectors IEC plug at one end, IEC socket at the other.
Ordering Information BC42A-29 (17-00365-19)
BC55D EIA-422/423 Communications Cable
Description Extension cable for both EIA-422 and 423.
Specification
Number Of Conductors 37, 18 twisted pairs plus one single
conductor.
Connectors One 37-way D-type male, one 37-way D-type female.
Wiring Straight through.
Typical Usage To extend either the BC19B (EIA-422), or
the BC19E (EIA-423) adapter cables when used with synchronous
controllers.
Ordering Information
BC55D-25, -50.
BC56H SCSI Adapter Cable
BC56H
Description Single-ended SCSI cable.
Connectors One 68-way, high-density, Honda, female, straight
connector with cut-out locating keys; one 50-way low-density,
Centronics style, straight connector.
Typical Usage To connect the first SCSI device to an InfoServer
150.
Ordering Information
E0-BC56H-03, -06, -09 (feet)
(17-02008-01, -02, -04).
The BC56H-03 and the BC19J-1E are generally shipped with non-embedded
SCSI options.
BCC04/BCC14 EIA-232 Modem Cables
Description Modem cables specifically designed for the
PC product family, and may also be used as a printer cable for
the Rainbow PC. The BCC04 is very similar to the BC22F, and the
BCC14 is very similar to the BC22E.
Specification Gauge: 26-AWG
Number Of Conductors 25 for BCC04, 16 for BCC14.
Connectors One male, and one female 25-way D-type. These
connectors, unlike the BC22E/F cables have screw fastenings through
the mouldings.
Wiring Pin to pin.
BCC04 - all pins are connected.
BCC14 - only pins 1, 2, 3, 4, 5, 6, 7, 8, 12, 15, 17, 19, 20,
22, 23, 24.
Typical Usage Modem connection to PCs fitted with a 25-way
serial port, or, a printer connection to a DEC Rainbow.
Ordering Information
BCC04-10, E0-BCC04-25, E0-BCC04-50. E0-BCC14-10.
BCC05 Printer Cable
Description A printer cable designed for connecting printers
to the DECmate and Professional PCs and the VT200 series terminals.
Not suitable for the Rainbow PC which uses the BCC14 cable.
Specification Gauge: 26-AWG
Number Of Conductors 7
Connectors One 25-way female D-type (printer end), one
9-way female D-type (PC end), with screw fasteners.
Wiring Null Modem.
9-Way End 25-Way End
Ground 1 1 Ground
Tx 2 3 Rx
Rx 3 2 Tx
RTS 4 5 CTS
DTR 5 6 DSR
DSR 6 20 DTR
Signal Ground 7 7 Signal Ground
Ordering Information
EO-BCC05-10, -25, -50.
BCC27 VRT13 Color Monitor Cable
BCC27
Description: VRT13 monitor cable, 5 feet long
Specification:
Connectors: 9-way D-type, male connector with fixing screws
and 15-way D-type, male connector with fixing screws.
Typical Usage: To connect a VRT13 monitor to a VAXstation
4000 VLC. Also used with VRT13 based PCs.
Ordering Information:
BCC27-05
p/n 30-34762-03
BCC45 PC Keyboard Extension Cable
BCC45
Description Five feet long keyboard extension cable suitable
for the following keyboards :
LK450-AA, PCXAL-xx, and LK250-PA.
Specification
Connectors One 6-way mini-DIN male (PS/2 style), one 6-way
mini-DIN female.
Ordering Information
BCC45-06.
BN12A-2E Power Cable
Description 2.5m, power cable with special connector. For
UK use.
Specification
Connectors One straight IEC320 C15 socket with keyed cutout,
one UK 240v plug.
Typical Usage Alpha 3000-500, DECNIS.
Ordering Information
BN12A-2E (17-00209-03).
BN18B-4E Power Cable
BN18B
Description 4.5m, power cable with straight connector.
For UK use.
Specification
Connectors One straight IEC320 C19 sockey, one UK 240v
plug.
Typical Usage HSC65, HSC95.
Ordering Information
BN18B-4E (17-00209-05).
BN19A Power Cable
BN19A
Description Grey, 2.5m, power cable with right-angled connector.
For UK use.
Connectors Connector 1 - Straight IEC320 C13 socket. Connector
2 - UK 240v plug.
Typical Usage General purpose.
Note: The BN19A-2E is interchangeable with the BN26D-2E.
The BN26D-2E is Colored black, whereas the BN19A-2E is grey.
Ordering Information
BN19A-2E (17-00209-15).
BN19B Power Cable
BN19B
Description Grey, 2.5m, power cable with right-angled connector.
For UK use.
Connectors One right-angled IEC320 C13 socket, one UK 240v
plug.
Typical Usage General purpose.
Ordering Information
BN19B-2E (17-00209-18).
BN20E-2E Power Cable
BN20E
Description Black, 2.5m, power cable with right-angled
connector, for UK use.
Connectors One right-angled IEC320 C15 socket with shoulder,
one UK 240v plug.
Typical Usage LANbridge 150, LANbridge 200, DECrepeater
200.
Ordering Information
E0-BN20E-2E (17-00209-04).
BN21H SCSI Cable
BN21H
Description: SCSI cable used for 8-bit single-ended communications.
8-bit single-ended SCSI cables are also known as "A"
cables.
Connectors Two 50-way high density Honda male, straight,
with thumb latches.
Typical Usage
1. To interconnect adjacent BA350 shelves.
2. To daisy-chain BA353 Desktop Expansion boxes.
3. To connect the HSJ40 shelf to an SBB shelf in a data centre
cabinet.
4. To connect BA350 shelves to certain host systems.
5. To connect HSC9X-SX HSC SCSI Data Channels, via the bulkhead
I/O panel to a BA350 shelf within that HSC cabinet.
Ordering Information
BN21H-0C (0.3m), BN21H-0E (0.5m), BN21H-01, BN21H-1E (1.5m), BN21H-02,
BN21H-03, BN21H-05.
(17-03566-18, -09, -16, -17, -15, -10, -11).
BN21J SCSI Cable
BN21J
Description
SCSI cable used for 8-bit single-ended communications. 8-bit single-ended
SCSI cable are also known as "A" cables.
Connectors
50-way, high density Honda male right angled connector with screw
attachment, and 50-way high density Honda male, straight with
thumb latches.
Ordering Information
BN21J-0E (0.5m), BN21J-01, -02, -03, -05.
(17-03566-03, -02, -01, -04, -05).
BN21K 16 bit Differential SCSI Cable
BN21K
Description
16 bit differential cable
Connectors
- Connector 1 - 68-way, high density male, right angled connector
with jackscrews.
- Connector 2 - 68-way high density male, straight connector
with thumb screws.
Ordering Information BN21K-01, BN21K-02, BN21K-03, BN21K-05,
BN21K-10, BN21K-15, BN21K-20 (metres). (17-03565-xx).
BN21L 16 bit Differential SCSI Cable
BN21L
Description
16-bit differential SCSI cable. Very similar to the BN21K cable
(above), except that the BN21L has two right angled connectors.
The maximum total length of a differential SCSI bus is 25 metres.
16-bit differential SCSI cables are also known as "P"
cables.
Connectors
Two 68-way, high density Honda, male, right angled connectors
with jackscrews.
Ordering Information
BN21L-0B (0.15m), -0E (0.5m), -01, -02, -03, -05, -10, -15, -20.
(17-03565-xx).
BN21M SCSI Cable
Description
StorageWorks "Transition" cable. So called because the
cable provides a transition between different connector types.
Connectors
68-way, high density Honda, male, right angled connector with
jackscrews, and 50-way, low density, male, straight with bail
locks.
Ordering Information
BN21M-02, -03, -05, -10, -15, -20.
(17-03567-xx).
BN21N SCSI Cable
Description
StorageWorks "Transition" cable. So called because the
cable provides a transition between different connector types.
Connectors
68-way, high density Honda, male, right angled connector with
jackscrews, and 50-way, high density, Honda, male, straight with
thumb latches.
Ordering Information
BN21N-02, -03, -05, -10, -15, -20 (metres).
(17-03567-xx).
BN21P-0B SCSI "Y" Cable
BN21P-0B
Description
SCSI "Y" cable 0.15 metres long. Designed for StorageWorks
products to facilitate configuration.
This "Y" connection cable is used with the 68-pin H879-AA
differential terminator block to allow :
- Mid-bus positioning for single connector devices.
- Removal of mid-bus devices without disabling the bus.
- Removal of end-bus devices from the bus without disabling
the bus.
Specification
Connectors
50-way low density, straight connector at the base of the "Y",
and 68-way high density, special, female connectors for each arm
of the "Y".
Ordering Information
BN21P-0B (0.15m or 6 inches).
(17-03623-01).
BN21P-02 SCSI Adapter Cable
Description
Two metre long adapter cable for connecting VAXstation 3100 Models
38 or 48 which have an 8-bit single-ended SCSI bus, to StorageWorks
building block shelf (BA350). This is a transition cable. So called
because it provides a transition between different connector types.
NOTE : This cable cannot be used in any other configuration
or with any other system.
Specification
Number Of Conductors 38.
Connectors
68-way, high-density, Honda, female, straight, connector without
keyed cut-outs at the VAXstation end, 50-way high density, Honda,
male, straight, connector at the BA350 end.
Ordering Information
BN21P-02 (17-03631-01).
NOTE : The BN21P-02 is dissimilar to the BN21P-0B which
is a "Y" cable.
BN21R Fast SCSI Cable
BN21R
Description
SCSI cable with the correct impedance and internal wiring to meet
SCSI-3 specifications which were developed for fast single-ended
SCSI.
Although the BC09D cable has the same connector types, its internal
wiring and impedance were designed to SCSI-2 specifications, so
the BC09D is not suitable for use with demanding fast SCSI applications.
Note. Virtually all SCSI cables with a "BC" designation
are not wired to SCSI-3 specifications, whereas virtually all
cables made with a "BN" designation are wired to SCSI-3
specifications.
Connectors One male, 50-way, high-density, straight; and
one male 50-way low-density, right-angled.
Ordering Information
BN21R-0E, -01, -02. (17-03742-13, -01, -14)
BN21V SCSI "Y" Adapter Cable
Description "Y" configuration adapter cable used
for = single-ended SCSI, 0.15 m long.
Connectors 50-way high-density male connector at the base
of the "Y", and a 50-way low-density female connector
at each of the two arms of the "Y".
Typical Usage To provide connection to, and SCSI bus I
termination for, a PMAZC Single-ended SCSI K controller mounted
in a host system. In this configuration the BN21V would be connected
as' follows: base - to PMAZC module, arm 1 - to H8574-A Single-ended
SCSI Terminator, arm -2perhaps to a BN23G single-ended, fast SCSI
cable which is in turn connected to a BA350 pedestal.
Ordering Information BN21V-0B (17-03821-01)
BN21W SCSI "Y" Adapter Cable
BN21W
Description "Y" configuration adapter cable used
for Fast Wide Differential SCSI, 0.15 m long. Connectors 68-way
high-density male connector at the base of the "Y",
and a 68-way high-density female at each of the two arms of the
"Y".
Typical Usage To provide connection to, and SCSI bus termination
for, a KZPSA Fast Wide Differential SCSI controller module mounted
in a host system. In this configuration the BN21W would be connected
as follows: base - to KZPSA module, arm 1 - to H879 -AA Differential
SCSI Terminator, arm 2 - perhaps to a BN21K Differential SCSI
cable connected to a DWZZA-VA in a BA350 pedestal.
Ordering Information BN21W-0B (17-03822-01).
BN21X SCSI Adapter Cable
Description "Y" configuration adapter cable used
to connect a 16-bit bus (operating in 8-bit mode) to a 50-way
high-density connector.
Connectors 50-way high-density male at the base of the
"Y", 68-way high-density female at each of the two arms
of the "Y".
Typical Usage With Sun Microsystems or Hewlett-Packard
systems.
Ordering Information BN21X-0B (17-03623-02)
BN21Y SCSI "Y" Adapter
Description "Y" configuration adapter cable.
Connectors 50-way low-density male connector at the base
of the "Y", 50-way low-density female connector at each
of the two arms.
Typical Usage
Ordering Information BN21Y-0B (17-03829-01)
BN22E-2E Power Cable
BN22E
Description
Black, 2.5 m, power cable designed for the VAX 4000 for use in
the United Kingdom.
Specification
Connectors
One right-angled IEC320 C15 socket, one UK 240v plug.
Typical Usage BA400 enclosure.
Ordering Information BN22E-2E (17-00209-13).
BN23G Fast SCSI Cable
Description
SCSI cable with the correct impedance and internal wiring to meet
SCSI-3 specifications which were developed for fast single-ended
SCSI.
Although the BC09D cable has the same connector types, its internal
wiring and impedance were designed to SCSI-2 specifications, so
the BC09D is not suitable for use with demanding fast SCSI applications.
Note. Virtually all SCSI cables with a "BC" designation
are not wired to SCSI-3 specifications, whereas virtually all
cables made with a "BN" designation are wired to SCSI-3
specifications.
Connectors
One male, 50-way, high-density, straight; and one male 50-way
low-density, straight.
Ordering Information
BN23G-0E, -01, -02.
(17-03742-08, -09, -04)
BN24A ThinWire Daisy Chain Cable
BN24A
Description
The BN24A-2E daisy-chain connector cable is a 2.5 metre twin conductor
co-axial cable that connects PC/workstations to a daisy-chain
faceplate connector. The cable is terminated at the PC end with
a BNC- plug, and at the,face plate end with a tap plug that fits
into the daisy-chain receptacle.
Specification
Minimum bending radius is 1.5 inches.
Number Of Conductors
One 5 m co-axial conductor "folded in half" to provide
a twin conductor 2.5 m long with a BNC connector at the "fold",
and two connections built into the tap connector to provide continuity
for the two Thinwire daisy chain ends inside the face-plate. When
the BN24A is removed from the face-plate, the contacts inside
the face-plate connector automatically re-make the behind the
wall Thin-wire circuit.
Typical Usage
Connects to the H3114-AA Daisy-Chain In Wall Connector (pack of
eight), which is housed in a European Wall Box 80mm x 100mm, part
number H3111-FB- white, and H3111-FC - grey, (packs of eight),
or the international wallbox (80mm x 100mm), kit of eight (H3111-GB).
NOTE : ONLY eight workstations may be attached to
a thin wire segment when using the "Daisy Chain" system.
The maximum length of thin wire segment cabling behind the wall
is 125 meters. The remaining 60 meters of segment length is reserved
for the round trip length of the daisy chain office cables.
Ordering Information
E0-BN24A-2E, -3E.
BN24B FDDI To FDDI Cable Assembly
BN24B
Description
The FDDI cables consist of dual fibres in a round construction
for flexibility. The FDDI connectors have field-programmable keying,
and are supplied with tethered dust covers.
Specification
Fibre : Dual-window 62.5/125 micron fibre. FDDI products use the
1300 nm wavelength. The maximum link length for FDDI is 2000m.
The connectors meet ANSI, FDDI, and PMP requirements.
Number Of Fibres 2.
Connectors
Two keyed FDDI Media Interface Connectors (MIC) which are field
programmable for the appropriate type of FDDI connection, (ie.
Port A, B, M, or S).
Wiring Cross-over.
Ordering Information E0-BN24B-01, -03, -4E, -10, -20, -30.
BN24D FDDI To ST Cable Assembly
BN24D
Description
Consists of a dual fibre of zipcord construction for flexibility.
Each cable is Color coded with red and black connector boots
for easy identification of transmit and receive.
Specification 62.5/125 micron fibre.
Number Of Fibres 2.
Connectors
One FDDI connector, and two Color coded 2.5mm bayonet ST-type
connectors. The black boot indicates the connector is associated
with the optical output of the FDDI equipment, the red, the input.
Wiring Can be cross-over, or non-crossover.
Ordering Information E0-BN24D-01, -03, -4E, -10, -20, -30.
BN24E Dual ST Cable Assembly
BN24E
Description
A dual fibre cable. The zip-cord joining the two lengths together
may be ripped down to create two separate cables. Each component
cable is Color coded with red and black connector boots for easy
identification of transmit and receive.
Specification
62.5/125 micron fibre. Bandwidth is 160/500 MHz-km 850/1300 mn
wavelength. Minimum bending radius is 1.5 inches.
Number Of Fibres 2.
Connectors Total of four 2.5mm bayonet ST-type connectors.
Wiring
Ordering Information
BN24E-01, -03, -4E, -10, -30.
BN24F 10BaseT Office Cable
Description
Used to connect the 8-way MJ (Modular Jack) port of a 10BaseT
workstation to an 8-way MJ faceplate outlet jack. The BN24F
is now replaced by the BN24Q.
Specification
EIA component tested to 20 Mhz. 26 AWG.
Number Of Conductors
Four, ( ie. Two twisted-pairs ).
Connectors
8-Way MP at each end.
Wiring
Cross-over
Pin Pin
1 3
2 6
3 1
6 2
Typical Usage
To connect a PC fitted with a DE101/201 Ethernet controller to
an MJ socket in a wall faceplate.
Use as the office cable for the DECrepeater 350 which does NOT
have a built-in crossover.
Ordering Information BN24F-03, -04, -07.
BN24H DEC423 Office Cable
BN24H
Description
Connects the 6-way MMJ (Modified Modular Jack) port of a terminal
or printer to the 8-way MJ in a faceplate.
Specification
EIA component tested to 20 MHz.
Number Of Conductors
6, in 3 twisted-pairs.
Connectors
One 6-way MMP, one 8-way MP.
Wiring
Cross-over
Signal 6-Way MMP 8-Way MP Signal
DTR 1 8 DSR
Tx Data 2 2 Rx Data
Tx Ground 3 1 Rx Ground
Rx Ground 4 3 Tx Ground
Rx Data 5 6 Tx Data
DSR 6 7 DTR
Typical Usage
To connect a DEC423 video terminal or printer to an 8-way MJ wall
outlet.
Ordering Information
BN24H-03, -04.
BN24J DEC423 Equipment Cable
BN24J
Description
Connects the 6-way MMJ port of a DEC423 server to an 8-way MJ
patch panel insert.
Specification
Number Of Conductors
6, in 3 twisted-pairs.
Connectors
One 6-way MMP, one 8-way MP.
Wiring
Pin-To-Pin
Signal 6-Way MMP 8-Way MP Signal
DTR 1 7 DTR
Tx Data 2 6 Tx Data
Tx Ground 3 3 Tx Ground
Rx Ground 4 1 Rx Ground
Rx Data 5 2 Rx Data
DSR 6 8 DSR
Typical Usage
To patch a 6-way MMJ port of a DECserver 300 to an 8-way MJ patch
panel insert jack.
Ordering Information
BN24J-01, -03, -07.
BN24K DEC423 Equipment Cable
BN24K
Description
Connects the 36-way port of a DECserver 200/DL, or a CXA16 terminal
server module to the 50-way port of the H3107-M patch panel insert.
Specification
Shielded
Number Of Conductors
36, in 18 twisted-pairs.
Connectors
One right angle 36-way, and one straight 50-way Centronics style
type, male connector.
Wiring
Typical Usage
Two of these cables would be used to connect a CXA16 terminal
server module to a H3107-M patch panel insert.
Ordering Information
BN24K-03.
BN24L DEC423 Equipment Cable
BN24L
Description
"Octopus" cable used to connect to the 6-way MMJ ports
of a DEC423 terminal server, to the 50-way port of the H3107-M
patch panel insert.
Specification
Number Of Conductors
48, in 24 twisted-pairs.
Connectors
One straight, 50-way, male, Centronics style, and eight 6-way
MMP connectors each of which are numbered.
Wiring
Typical Usage
To connect the MMJ ports of a DECserver 300 to the H3107-M patch
panel insert.
Ordering Information
BN24L-03 (17-02920-01).
BN24N DEC423 Equipment Cable
BN24N
Description
A one-to-eight "octopus" cable to connect the 36-way
port of a DECserver 200/DL, or a CXA16 terminal server module,
to the 8-way MJ ports of an H3107-N patch panel insert. Each of
the 8 leads is numbered from 1 to 8.
Specification
Number Of Conductors
24, in 12 twisted-pairs.
Connectors
One right angled, 36-way centronics style, male, and eight 8-way
MPs, each being numbered.
Wiring
Typical Usage
Two of these cables would be used to connect a CXA16 terminal
server module, to an H3107-N patch panel insert.
Ordering Information
BN24N-03 (17-02924-01).
BN24Q 100BaseT or 10BaseT Cable
Description Unshielded Twisted Pair cable for either 100BaseT
(Fast Ethernet), 10BaseT (Ethernet) use.
The BN24Q cable replaces the BN24F 10BaseT cable.
Specification Impedance is 100 ohms. Cable is used for
10BaseT, 100BaseTX, and 100Base-T4 applications.
Number of Conductors 8 conductors in 4 twisted pairs. Each
conductor is 24 AWG, stranded.
Connectors 8-way Modular Plug (RJ45) connector at each
end of the cable.
Wiring Crossed.
Connector 1 Connector 2
pin pin
1 3
2 6
3 1
4 7
5 8
6 2
7 4
8 5
Typical Usage This cable would be used when a cross-over
is required, for instance, when connecting two DE500 Fast Ethernet
adapters together, or, when connecting a DE500 to a DECSWITCH
900 EE/EF (this has no internal cross-over).
Ordering Information BN24Q-0E, -01, -03, -04, -07.
(P/N 17-04308-01, -02, -03, -04, -05).
BN25G Data Grade Equipment Cable
BN25G
Description
High performance UTP cable used to interconnect two 8-way MJs.
May also be used as an ISDN office cable.
Replaces BN24G.
Category 5 Cable.
Specification
24 AWG stranded conductors.
Number Of Conductors
8, in 4 twisted-pairs.
Connectors
Two 8-way MPs.
Wiring Pin-To-Pin.
Pin 10BaseT Signal
1 Tx+
2 Tx-
3 Rx+
4 N/C
5 N/C
6 Rx-
7 N/C
8 N/C
Typical Usage
Connects a port of a DECrepeater 350 (DETPR), to an H3107-L, or
an H3107-N patch panel. Also interconnects H3107-L and H3107-M,
and H3107-L and H3107-N patch panels. Use as the office cable
for the DECrepeater 90T which has bulit in crossover.
Use this cable where high performance is required.
Ordering Information
BN25G-0E (0.5m), -01, -03, -04, -07.
(17-03212-01, -02, -03, -04, -05).
BN25H Unshielded Office Cable for TP FDDI.
Description:
UTP (unshielded twisted-pair) cable for use with copper FDDI devices.
Specification:
Unshielded, 100-ohm, Category 5, office cable. 24 AWG.
Number of Conductors:
8 conductors in 4 twisted pairs.
Connectors:
Two 8-way Modular Plugs (RJ45).
Wiring
Crossed.
Plug A Plug B
1 7
2 8
3 3
4 4
5 5
6 6
7 1
8 2
Typical Usage:
Typically to connect two FDDI devices directly, or an FDDI interface
card such to an office faceplate.
Ordering Information:
BN25H-03 (p/n 17-03909-03).
BN26M High Performance Office Cable
BN26M
Description
Shielded cable designed for office or equipment use, to be used
with an active network device such as the DECrepeater 90T which
utilizes internal crossover.
Category 5 cable.
Specification
26AWG stranded conductors.
Number Of Conductors
Eight in four twisted pairs plus shielding.
Connectors
Shielded 8-way MP at each end.
Wiring
Straight through.
8-Way MP 8-Way MP
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
Typical Usage
Can provide connecting for application such as 802.3/10 base T,
802.5/Token Ring, and ISDN.
Ordering Information
BN26M-03,04,07.
(17-03194-03, -04, -05).
BN26N 10BaseT Office Cable
Description
Shielded office cable designed for 10 Base T repeaters, such as
the DECrepeater 350 which do not incorporate internal crossover.
Specification
Number Of Conductors
Four in two twisted pairs, plus shielding.
Connectors
Shielded 8-way MP at each end.
Wiring
Crossover
8-Way MP 8-Way MP
1 3
2 6
3 1
6 2
Typical Usage
Connects a shielded 8-way MJ port of a 10BaseT workstation to
the shielded 8-way MJ faceplate outlet jack (H3112-H).
Ordering Information
BN26N-03,04,07.
(17-03195-01, -02, 03).
BN26R Octopus Cable
BN26R
Description
A 50-way to eight 8-way "Octopus" equipment cable used
to connect the eight 8-way ports of 10BaseT repeaters or DECserver
Terminal Servers to the 50-way connector of the H3107-M Patch
Panel. The BN26R is the direct replacement for the BN24M cable.
Specification
Number Of Conductors
48 conductors ( 8 x 3 twisted pairs ).
Connectors
One straight, 50-way centronics style male, (plug 9), and eight
8-way MP (Modular Plug) connectors, (plugs 1-8).
Typical Usage
To connect the eight 8-way MJ ports of the :
- DETPR (DECrepeater 350)
- DETMR (DECrepeater 90T)
- DSRVE (DECserver 90TL)
- DSRVW-DA (DECserver 700 DL)
....to the H3107-M Patch Panel.
NOTE : The DECrepeater 350 does NOT have a built-in
cross-over, therefore a crossed-over cable (eg. BN24F-xx) would
be needed between the office Face Plate and the device in order
to achieve a net cross-over. The DECrepeater 90T DOES have a built-in
cross-over, so a straight wired cable (eg. BN26K-xx) would be
needed between the Face Plate and the device.
Ordering Information
BN26R-03 (17-03518-01).
BN26S Shielded Office Cable for TP FDDI.
Description:
STP (shielded twisted-pair) cable for use with copper FDDI devices.
This cable is the shielded version of the BN25H.
Specification:
Shielded, 100-ohm, Category 5, office cable. 24 AWG.
Number of Conductors:
8 conductors in 4 twisted pairs, plus shield.
Connectors:
Two 8-way Modular Plugs (RJ45) with shields.
Wiring
Crossed.
Plug A Plug B
1 7
2 8
3 3
4 4
5 5
6 6
7 1
8 2
Shield Shield
Typical Usage:
Typically to connect two FDDI devices directly, or an FDDI interface
card such to an office faceplate.
Ordering Information:
BN26S-03 (p/n 17-03910-03).
BN26U 10BaseT "Octopus" Adapter
Cable.
Description:
"Octopus" cable to adapt a 50-way Telco socket on a
10BaseT repeater to twelve individual RJ45 plugs.
Specification:
Number of Conductors:
Total number of conductors is 48 (24 twisted pairs). There are
4 conductors at each of the 12 RJ45 plugs.
Connectors:
One 50-way Telco connector, and twelve 8-way RJ45 plugs (MPs,
or Modular Plugs).
Wiring:
The pin/signal assignment at the RJ45 connector is :
Pin Signal
1 Rx+
2 Rx-
3 Tx+
6 Tx -
Typical Usage:
To connect one of the two 50-way Telco sockets on the DECrepeater
900GM to a patch panel.
Ordering Information:
BN26U-03 (p/n 17-03912-01)
BN31G SCSI Cable
Description
General purpose SCSI cable
Specification
Connectors:
- Connector 1 - 68-way, high density, male, straight.
- Connector 2 - 68-way, high density, male, straight.
Typical Usage
To connect a SCSI device to a BA364 or BA362 Storage enclosure
which requires a straight entry 68-eay cable.
Ordering Information: BN31G-01, -1E, -02 (p/n 17-03916-03,
-10, -01).
BN31K KZPSC Cable/Bulkhead Assembly
BN31K
Description Internal cable and bulkhead plate with socket
designed to present the third SCSI channel of a KZPSC PCI RAID
controller to a socket at the I/O panel of a pedestal AlphaServer
2000/2100. Cable is 0.5m long.
Connectors 68-way, male, right-angled IDC ribbon cable
connector at the KZPSC module end, connected via a flat ribbon
cable to a bulkhead assembly consisting of a 68-way, very-high-density
(0.8mm pitch) female connector set into a mounting plate suitable
for fixing into a convenient I/O slot.
Typical Usage To enable the connection of an external StorageWorks
storage pedestal to the third SCSI channel of the KZPSC controller
as follows: 8-bit SCSI pedestal, eg, BA350-KF --- use BN31L-1E
external cable, 16-bit SCSI pedestal, eg BA356-KB (BUS 1) ---
use BN31S-1E, 16-bit SCSI pedestal, eg BA356-KB (BUS 2) --- use
BN31M-1E.
Ordering Information BN31K-0E (17-04108-01)
BN31L Single-ended SCSI Cable
BN31L
Description Cable designed to connect an external port
of the KZPSC RAID controller to an 8-bit StorageWorks a pedestal.
Cable length is 1.5 m.
Connectors 68-way, male, straight, 0.8mm pitch - very high
density - connector withK thumb screws (this looks like a sub-miniature
Centronics style connector at the KZPSC RAID controller end, and
a 50-way high-density, male, straight connector at the StorageWorks
enclosure end.
Typical Usage To connect a KZPSC PCI RAID controller's
external port to an external BA350-KF pedestal. The KZPSC-BA directly
presents two VHD 68-way ports at the bulkhead for two of its SCSI
busses, if its third SCSI bus was required for external use then
a BN31K-0E Internal Cable/Bulkhead Assembly would need to be installed.
Ordering Information BN31L-1E (17-04107-01).
BN31M Single-ended SCSI Cable
Description Cable designed to connect an external port
of the KZPSC RAID controller to an 16-bit StorageWorks a pedestal.
Cable length is 1.5 m.
Connectors 68-way, male, straight, 0.8mm pitch - very high
density - connector with thumb screws (this looks like a sub-miniature
Centronics style connector) at the KZPSC RAID controller end,
and a 68-way high-density, male, straight connector at the StorageWorks
enclosure end.
Typical Usage To connect a KZPSC PCI RAID controller's
external port to an external BA356 pedestal. The BN31M cable would
be selected when connecting to BUS 2 (Output) at the BA356's Personality
Module. The similar BN31S would be used for BUS 1 connection.
The KZPSC-BA directly presents two VHD 68-way ports at the bulkhead
for two of its SCSI busses, if its third SCSI bus was required
for external use then a BN31K-0E Internal Cable/Bulkhead Assembly
would need to be installed.
Ordering Information BN31M-1E (17-04107-02)
BN31S Single-ended SCSI Cable
Description Cable designed to connect an external port
of the KZPSC RAID controller to an 16-bit StorageWorks a pedestal.
Cable length is 1.5 m.
Connectors 68-way, male, straight, 0.8mm pitch - very high
density - connector with thumb screws, (this looks like a sub-miniature
Centronics style connector) at the KZPSC RAID controller end,
and a 68-way high-density, male, right-angled connector at the
StorageWorks enclosure end.
Typical Usage To connect a KZPSC PCI RAID controller's
external port to an external BA356 pedestal. The BN31S cable would
be selected when connecting to BUS 1 (Input) at the BA356's Personality
Module. The similar BN31M would be used for BUS 2 connection.
The KZPSC-BA directly presents two VHD 68-way ports at the bulkhead
for two of its SCSI busses, if its third SCSI bus was required
for external use then a BN31K-0E Internal Cable/Bulkhead Assembly
would need to be installed.
Ordering Information BN31S-1E (17-04107-03)
BN31V SCSI Cable
Description
General purpose fast SCSI cable. 1 m long. This cable is functionally
the same as FR-PCXAR-WK (p/n 17-04154-01)
Specification
Connectors
- Connector 1: 68-way, high density, male, straight.
- Connector 2: 50-way, high density, male, straight.
Typical Usage
To connect a SCSI device to a BA364 or BA362 Storage enclosure
which requires a straight entry 68-way cable.
Ordering Information: BN31V-01 (p/n 17-03567-24)
BN31W SCSI Cable
General purpose fast SCSI cable. 1 m long. This cable is functionally
the same as FR-PCXAR-WL (p/n 17-04154-02)
Specification
Connectors
- Connector 1: 68-way, high density, male, straight.
- Connector 2: 50-way, low density, male, straight.
Typical Usage
To connect a SCSI device to a BA364 or BA362 Storage enclosure
which requires a straight entry 68-way cable.
Ordering Information: BN31W-01 (p/n 17-03567-21)
BN34A Dual ST-SC Fibre-Optic Cable
Description Fibre Optic cable of zipcord construction with
ST push-pull connectors on one end, and SC connectors on the other.
Specification
Number of Conductors Dual 62.5/125-micron multi-mode fibre
conductors.
Connectors Two SC connectors on one end, and two ST push-pull
connectors on the other. The connectors at each end of the cable
have a Red and Black boot to identify the Transmit and Receive
signal path.
Typical Usage
Ordering Information BN34A-01, -2E, 03, -4E, -10, -20,
-30 (17-04147-01, -02, -03, -04, -05, -06, -07)
BN34B Dual SC-SC Fibre-Optic Cable
BN34B
Description Fibre Optic cable of zipcord construction with
SC at each end.
Specification
Number of Conductors Dual 62.5/125-micron multi-mode fibre
conductors.
Connectors Two SC connectors at each end of the cable.
Typical Usage
Ordering Information BN34B-01, -2E, 03, -4E, -10, -20,
-30 (17-04138-01, -02, -03, -04, -05, -06, -07)
BN34C Dual ST-ST Fibre-Optic Cable
Description Fibre Optic cable of zipcord construction with
ST push-pull connectors at each end. The push-pull construction
provides easy insertion and high repeatability.
Specification
Number of Conductors Dual 62.5/125-micron multi-mode fibre
conductors.
Connectors Two ST push-pull connectors at each end of the
cable.
Typical Usage
Ordering Information BN34C-01, -2E, 03, -4E, -10, -20,
-30 (17-04145-01, -02, -03, -04, -05, -06, -07)
BN34D IC-SC Fibre-Optic Cable
Description Fibre Optic cable of zipcord construction with
SC connectors on one end, and an MIC onnector on the other.
Number of Conductors Dual 62.5/125-micron multi-mode fibre
conductors.
Connectors Two SC connectors on one end, and an MIC (FDDI
Media Interface Connector) on the other. The connectors at the
SC end of the cable have a Red and Black boot to identify the
Transmit and Receive signal path. The MIC connector is keyed and
is field programmable for the appropriate type of FDDI connection.
Typical Usage
Ordering Information BN34D-01, -03, -10. (17-04185-01,
-03, -05)
BN36A SCSI Adapter Cable
Description SCSI adapter cable with built-in 9-bit termination
designed to allow the correct connection of a narrow (8-bit) SCSI
device to a wide (16-bit) SCSI workstation. This adapter cable
is 0.16 metres (6 inches) long.
Specification
Connectors
- Connector 1 - 68-way high-density, male, straight.
- Connector 2 - 50-way high-density, female, straight.
Typical Usage To connect a narrow SCSI device such as a
TLZ07 to the 68-way SCSI connector on the AlphaStation 500. The
68-way connector would be connected to the AlphaStation and would
terminate the high-byte; the 50-way connector would be joined
to the high density 50-way end of a cable such as the BN23G, and
the other 50-way low-density end of the BN23G would connect to
the TLZ07 tape drive.
Note that this BN36A-0B adapter is not needed when connecting
devices designed for use with the newest AlphaStations, as these
devices, such as the appropriate TLZ09 option have a built-in
adapter.
Ordering Information BN36A-0B (17-04401-01)
BN41A DECserver900GM Octopus Cable.
Description Cable which connects to one of the 68-way connectors
of the DECserver900GM, and then presents four separate DB25 connectors,
each with EIA-232 data and full modem control signals. Cable is
3 metres in length.
Specification
Connectors Connector 1 - 68-way male, right-angled, Amplimite
D-subminiature, Connectors 2,3,4,5 - 25-way, male, D-type.
Wiring Pin/Signal Designation for the DB25 connectors.
Pin Signal
2 Tx Data
3 Rx Data
4 RTS
5 CTS
6 DSR
7 GND
8 DCD
12 SMI
20 DTR
22 RI
23 DSRS
Typical Usage The DB25 connectors would typically be connected
to the port of an EIA-232 Modem requiring full control signals.
Ordering Information BN41A-03 (17-03973-01).
BN41B DECserver900GM Octopus Cable.
Description Cable which connects to one of the 68-way ports
of the DECserver900GM, and then presents eight sets of data and
partial modem control signals on eight separate MP8 connectors.
Cable is 3 metres in length.
Specification
Connectors Connector 1 - 68-way male, right-angled, Amplimite
D-sub miniature, Connectors 2,3,4,5,6,7,8,9 - 8-way, Modular Plug.
Wiring Pin/Signal Designation for the MP8 connectors.
Pin Signal
1 Rx Data Common
2 Rx Data
3 Tx Data Common
4 CTS
5 RTS
6 Tx Data
7 DTR
8 DSR
Typical Usage The MP8 connectors would typically be used
with an H8585-AC MJ8 to DB25 adapter at the port of EIA-232 Modem.
Ordering Information BN41B-03 (17-03974-01).
BN41C DECserver900GM Adapter Cable
Description Cable which converts one of the 68-way ports
of the DECserver900GM to a 50-way Telco connector. Eight sets
(DL1-8) of signals will then be available at the Telco for subsequent
distribution at an Open DECconnect Patch Panel. Cable is 3 metres
in length.
Specification
Connectors Connector 1 - 68-way male, right-angled, Amplimite
D-sub miniature, Connector 2 - 50-way Telco connector.
Wiring
Connector 1 Connector 2 Signal Name
1 1 Tx Data 1
5 26 Tx Data COM 1
2 2 Rx Data 1
36 27 Rx Data COM 1
3 3 DSR 1
37 28 DTR 1
5 4 Tx Data 2
39 29 Tx Data COM 2
6 5 Rx Data 2
40 30 Rx Data COM 2
7 6 DSR 2
41 31 DTR 2
9 7 Tx Data 3
43 32 Tx Data COM 3
10 8 Rx Data 3
44 33 Rx Data COM 3
11 9 DSR 3
45 34 DTR 3
13 10 Tx Data 4
47 35 Tx Data COM 4
14 11 Rx Data 4
48 36 Rx Data COM 4
15 12 DSR 4
49 37 DTR 4
17 13 Tx Data 5
51 38 Tx Data COM 5
18 14 Rx Data 5
52 39 Rx Data COM 5
19 15 DSR 5
53 40 DTR 5
21 16 Tx Data 6
55 41 Tx Data COM 6
22 17 Rx Data 6
56 42 Rx Data COM 6
23 18 DSR 6
57 43 DTR 6
25 19 Tx Data 7
59 44 Tx Data COM 7
26 20 Rx Data 7
60 45 Rx Data COM 7
27 21 DSR 7
61 46 DTR 7
29 22 Tx Data 8
63 47 Tx Data COM 8
30 23 Rx Data 8
64 48 Rx Data COM 8
31 24 DSR 8
65 49 DTR 8
34 > 68 CABLE ID
Typical Usage The 50-way Telco connector would be typically
connected into an H3117-MA Snap-in 50-way to 8 x 8MPJ Patch Panel
Insert for the H3108 series Patch Panel Frame.
Ordering Information BN41C-03 (17-03972-01).
BN41D DECserver900GM Adapter Cable
Description Cable which connects to one of the 68-way ports
of a DECserver900GM and then presents eight sets of EIA-232 signals
with partial modem controls (DL1-8) on eight different DB25 connectors.
Cable is 3 metres in length.
Specification
Connectors Connector 1 - 68-way male, right-angled, Amplimite
D-sub miniature, Connectors 2,3,4,5,6,7,8,9 - 25-way D-type male.
Wiring Pin/Signal designation for the 25-way connectors.
Pin Signal
2 Tx Data
7 Tx Data COM
3 Rx Data
7 Rx Data COM
6 DSR
20 DTR
5 CTS
4 RTS
Typical Usage This cable is designed for the Netrider 900
package.
Ordering Information BN41D-03 (17-04214-01).
BNCIA CI Cable Set
Description
The BNCIA cable set is designed as the interface cable for Digital's
70Mbits dual path Computer Interconnect (CI). There are four cables
in the set; Transmit and Receive for the A path, and Transmit
and Receive for the B path.
Specification
Gauge is 0.410 inch diameter cable. Double braid and foil shields.
Number Of Conductors
Four separate co-axial cables.
Connectors
TNC type connectors at all ends.
Typical Usage
To connect VAXcluster nodes to the passive SC008 Star Coupler
"hub". The capacity of the CI is 16 nodes, and the maximum
separation between two nodes is 90m.
NOTE:
A Star Coupler must always be used, even for only two nodes, (eg.
connecting an HSC70 to a CIBCA), since the CI receivers are designed
to accept only the highly attenuated signals which are offered
by the SC008 which must be able to passively transmit signals
to up to 16 nodes. Use the SC008-AC for up to 8 nodes, and the
SC008-AD for between 9 and 16 nodes.
Ordering Information
E0-BNCIA-10, -20, -45.
BNE2A / BNE2B Ethernet Cable
Description
The BNE2A (Teflon insulation), and the BNE2B (PVC), is the cable
used for base-band 10 Mb/s Ethernet. Transceiver placements are
marked on the cable every 2.5m. Maximum length of a BNE2A/B segment
is 500m.
Specifications
IEEE 802.3, 10 Base 5, Beldon 9880. Gauge: 11.5 AWG, Impedance:
50 ohms.
Minimum bending radius: 20 cm (8 inches). Diameter: 1.0 cm.
Number Of Conductors
One co-axial conductor.
Connectors
"N" male co-axial connectors both ends.
Hardware
50 Ohm Impedance Terminator to correctly terminate an Ethernet
segment - P/N 12-19816-01.
Barrel connector to join two lengths of Ethernet cable together
- P/N 12-19817-01.
Loose end connectors to crimp onto unterminated cable - P/N 12-19118-00,
using the H3 Crimping Tool P/N 29-24662-00.
Ordering Information
E0-BNE2A/B-MA (23.4m),
E0-BNE2A/2B-MB (70.2m),
E0-BNE2A/B-MC (117m),
E0-BNE2B-ME (500m).
BNE3H / K / L / M and BNE4C / D and BNE4G -
Transceiver Cables
BNE4C
BNE4G
Description
These are Ethernet Transceiver cables which are fully IEEE 802.3
compliant. The maximum length for a transceiver cable is 50m.
BNE3x cables are low loss, whereas BNE4x cables are higher loss
but are thinner and are more suitable for office use.
BNExC, BNExD, BNExH, BNExK are PVC insulated.
BNExL, BNExM are Teflon insulated.
BNExD, BNExK, BNExM have right angled connectors.
BNExC, BNExH, BNExL have straight connectors.
Specification
For Low Loss:
Gauge: 20-AWG, impedance: 78 ohms.
Minimum bending radius: 10 cm.
Diameter: 1.3 cm.
For Office:
Minimum bending radius: 10 cm.
Diameter: 0.6 cm.
Number Of Conductors
8 (four twisted pairs), plus drain wire. Each TWP is screened
with foil. The cable is screened with both foil and braid.
Connectors
One male (device end), one female (transceiver end), 15-way D-type
connectors with slide latch for easy connection.
Wiring
Pin to pin.
Pin Signal Pin Signal
1 Shield 9 Collision Presence -
2 Collision Presence + 10 Transmit -
3 Transmit + 11 Reserved
4 Reserved 12 Receive -
5 Receive + 13 Power
6 Power Return 14 Reserved
7 Reserved 15 Reserved
8 Reserved
Typical Usage
To connect Ethernet devices to the Ethernet via H4005 Transceivers
or DELNIs. Only Teflon cables should be used in an environmental
airspace.
Use the BNE4G-02 for connection to EtherWORKS cards with an AUI
port.
The BNE4G-02 is available only in this 2m length. Customers who
require a longer cable may add a standard transceiver cable to
it it, to achieve the required length.
Ordering information
Straight Connectors
E0-BNE4C-02 2m PVC Office Cable
E0-BNE4C-05 5m PVC Office Cable
E0-BNE3H-05 5m PVC Cable
E0-BNE3L-05 5m Teflon Cable
E0-BNE3H-10 10m PVC Cable
E0-BNE3L-10 10m Teflon Cable
E0-BNE3H-20 20m PVC Cable
E0-BNE3L-20 20m Teflon Cable
E0-BNE3H-40 40m PVC Cable
E0-BNE3L-40 40m Teflon Cable
Right-Angle Connectors
E0-BNE4D-02 2m PVC Office Cable
E0-BNE4D-05 5m PVC Office Cable
E0-BNE3K-05 5m PVC Cable
E0-BNE3M-05 5m Teflon Cable
E0-BNE3K-10 10m PVC Cable
E0-BNE3M-10 10m Teflon Cable
E0-BNE3K-20 20m PVC Cable
E0-BNE3M-20 20m Teflon Cable
E0-BNE3K-40 40m PVC Cable
E0-BNE3M-40 40m Teflon Cable
BNE4G-02
Note : The BNE4G-02 has screw fittings at the PC (male) end, and
the normal slide latch at the transceiver (female) end.
BS19D EIA-232 Adapter Cable Kit
BS19D
Description
The BS19D is the EIA-232 synchronous adapter cable kit consisting
of the BC19D-02 V.24 cable, an EIA-232 adapter connector part
number 12-27591-01, and an information sheet EK-BS19D-IS.
Specification
Number Of Conductors
16 conductors in the BC19D cable, 13 in the 12-27591-01 EIA-232
adapter connector.
Connectors
The cable kit has one 25-way male D-type, and one 50-way female
D-type connector.The adapter connector has one male and one female
25-way D-type connector; the female end is to connect to the male
25-way connector of the BC19D cable.
Wiring
Pins 2,3,4,5,6,7,8,15,17,20,22,24,25 on the EIA-232 adapter connector
are connected pin to pin, no other pins are connected.
Typical Usage
To adapt the standard 50 pin synchronous output connector to BTs
low speed (9.6Kb/s) Kilostream.
Use the BC22F to extend the BS19D adapter.
Ordering Information
E0-BS19D-02.
BS23V V.24 / V.28 Adapter Cable Kit
Description
A synchronous adapter cable kit to adapt Digital's standard 50-way
synchronous connector to V.24 / V.28. This cable is very similar
to the BS19D-02 adapter cable, but includes SMI (Speed Mode Indication).
The kit includes a BC23V-02 cable, plus a 12-27591-01 adapter.
Specification
Number Of Conductors
Connectors
The BC23V-02 cable has one 50-way female, and one 25-way male
D-type connector. The adapter ( P/N 12-27591-01) has one male,
and one female 25-way connector.
Wiring
50-Way Signal Name 25-Way 50-Way Signal Name 25-Way
Pin Pin Pin Pin
1 CODE GROUND * 22 CLOCK 24
3 CODE 1 * 33 DTR 20
8 Tx DATA 2 34 DSR (A) 6
11 Rx DATA (A) 3 35 DSR (B) #
12 Rx DATA (B) # 36 RTS 4
13 LOCAL LOOP 18 37 DCD/I (A) 8
14 SMI 12 38 DCD/I (B) #
15 TEST 1 25 39 CTS (A) 5
17 RI 22 40 CTS (B) #
16 REM. LOOP 21 41 DCE GROUND #
18 Rx CLOCK (A) 17 44 DTE GROUND 7,#
19 Rx CLOCK (B) # 50 SPEED 23
20 Tx CLOCK (A) 15
21 Tx CLOCK (B) #
Typical Usage
To adapt Digital's 50-way synchronous output connector for V.24
/V.28 use.
Ordering Information
E0-BS23V-02
H8240 Flat 6-Conductor Cable
Description
Flat terminal interconnection cable with PVC insulation. For low
speed applications only.
Specification
26 AWG, stranded conductors.
Number Of Conductors
6 conductors in a flat jacket.
Connectors
H8220 - 6-way MMP (Modified Modular Plugs) in a pack of 50, may
be crimped with the H8241 Crimp Tool, onto a desired length of
H8240 cable to make "BC16E" terminal or printer cables.
Such a cable would require a cross-over connection.
Typical Usage
For office use only; not for use in building wiring.
Supports EIA-232, and EIA-423.
Ordering Information
H8240 1,000ft (305m) reel.
(17-00721-01).
H8240-A UTP High Performance Data Grade Cable
Description
The H8240-A is an EIA/TIA Category 5, high-performance, data grade,
unshielded twisted-pair cable. PVC insulated.
Specification
100 Ohm impedance, 24 AWG, stranded conductors.
Category 5.
Number Of Conductors
8 conductors in 4 twisted pairs.
Connectors
May be terminated with the H8226-AA 8-way modular plugs ( pack
of 50 ), using the H8100-G crimp tool, or the H8241 crimp tool
with the H8100-F die set.
Typical Usage
Can be used to make custom cables for applications that require
high speed data transmission. For office use only: not for use
in building wiring
Ordering Information
H8240-A is a 305m ( 1,000ft ) reel of cable (17-03167-01)
H8240-B STP High Performance Data Grade Cable
Description
The H8240-B is an EIA/TIA Category 5, high-performance, data grade,
shielded twisted-pair cable. PVC insulated.
Specification
100 Ohm, 26 AWG stranded conductors.
Number Of Conductors
8 conductors in 4 twisted-pairs plus shield.
Connectors
May be terminated with the H8226-AB 8-way shielded modular plugs
(pack of 50 ), using the H8100-G crimp tool, or the H8241 crimp
tool with the H8100-F die set.
Typical Usage
Can be used to make custom cables for applications that require
high speed data transmission. For office use only: not for use
in building wiring.
Ordering Information
H8240-B is a 305m ( 1,000ft ) reel of cable (17-03169-01)
H8245-A and H8246-A UTP Standard Data Grade
Cable
Description
The H8245-A UTP (Unshielded Twisted Pair) cable is a category
3, standard data grade cable, jacketed with PVC. The H8246-A cable
is jacketed with Teflon. These cable feature excellent pair-to-pair
near-end cross talk levels.
Specification
24 AWG, solid conductors, 100 Ohm.
Category 3.
Diameter of PVC cable is 0.48cm, diameter of teflon cable is 0.43cm.
Minimum bending radius is 2.54cm
Number Of Conductors 8 conductors in 4 pairs.
Typical Usage
For DEC423, maximum distances are :
- Up to 19.2Kb/s - 1000 feet
- Up to 38.4Kb/s - 500 feet
For 10BaseT :
- Maximum distance is 100m.
If it is required to terminate this cable with 6-way MMPs (Modified
Modular Plugs), use the H8226-00 (50 pack) connectors, and the
H8241 Crimp Tool.
Ordering Information
H8245-A, 1,000 feet reel (17-01313-01).
H8246-A, 1,000 feet reel (17-01286-00).
H8245-C and H8246-C UTP High-Performance
Data Grade Cable
Description
The H8245-C UTP (Unshielded Twisted Pair) cable is a Category
5, high-speed, high-performance cable, jacketed with flame-retardant
polyethylene. The H8246-C cable is jacketed with Teflon. These
cables feature excellent pair-to-pair near-end cross talk levels.
Specification
24 AWG, solid conductors, 100 Ohm.
Category 5.
Number Of Conductors
8 conductors in 4 pairs.
Typical Usage
These cables support high-speed applications including 16Mb/s
Token Ring at lobe lengths of 100m without signal amplifiers.
Ordering Information
H8245-C 1,000 feet reel. (17-03030-01)
H8246-C 1,000 feet reel. (17-03029-01).
H8245-D and H8246-D STP High-Performance
Data Grade Cable
Description
The H8245-D STP (Shielded Twisted Pair) cable is a Category 5
high-performance cable jacketed with flame-retardant polyethylene.
The H8246-D cable is jacketed with Teflon. These cables feature
excellent pair-to-pair near-end cross-talk levels.
Specification
24 AWG, solid conductors, 100 Ohm.
Category 5.
Number Of Conductors
8 conductors in 4 pairs, plus shielding.
Typical Usage
These cables support high-speed applications including 16Mb/s
Token Ring at lobe lengths of 100m without signal amplifiers.
Ordering Information
H8245-D 1,000 feet reel (17-03170-01)
H8246-D 1,000 feet reel (17-03171-01).
H0401 Crossover Switch
H0401 Crossover Switch
H8571/H8575 DEC423 Passive Adapters
Description
The H8571/H8575 E1A-423 to EIA-232 series passive adapters adapt
25-way and 9-way D-type sub-miniature connectors to Modified Modular
Jacks (MMJ).
H8575-A
MMJ to 25-way, female, filtered D-type with jack screws for mating
to a device's (male) connector.
Wiring: Straight through.
H8575-B
MMJ to 9-way, female, filtered D-type with jack screws for mating
to the 9-way (male) printer port of an early Digital terminal.
Virtually obsolete.
Wiring: Straight through
H8571-C
MMJ to 25-way, male, unfiltered D-type with mounting nuts for
securing to cables such as the BC22D which has female connectors.
Wiring: Crossed.
H8575-D
MMJ to 25-way, male, filtered D-type with jack screws for connection
to the printer port (female) of the Rainbow (PC100) Personal Computer.
Wiring: Crossed
H8575-E
MMJ to 25-way, male, filtered D-type with jack screws for connection
to LJ250 Color printers. Also suitable for adapting printers
which are non-Digital, and have a female port.
Wiring: Straight through.
H8571-J
MMJ to 9-way, female, D-type with jack screws for mating to PC
style 9-pin (male) port. This adapter conforms to EIA-574.
Wiring: Straight through.
NOTE: The pin/signal designation is different to the H8575-B.
Where "Crossed" indicates the EIA-232 Transmit Data
is connected to the DEC-423 Receive Data, and vice versa, and
similarly with DTR and DSR. See also Appendix B.
Ordering Information
E0-H8575-A
E0-H8575-B
H8571-C
H8575-D
H8575-E
E0-H8571-J
Here are some pictures of the adapters. The first picture shows,
anti-clockwise from bottom left, H8575-A, H8575-B, H8571-C, H8575-D,
H8575-E. The second picture shows the H8571-J.
H8575-A etc
H8571-J
H8575-A Schematic
H8575-B Schematic
H8571-C Schematic
H8575-D Schematic
H8575-E Schematic
H8571-J Schematic
Appendix A EIA Standards, Speed and Distance
Since 1985, the Electrical Industries Association (EIA), decided
to replace the 'RS-' identifier with EIA', therefore RS-232-C
has been replaced by EIA-232-D. These two standards are compatible
with each other. The EIA-232-D/CCITT V.24/V.28 standard was originally
designed to specify the connection between a local interface and
a modem. It was not intended to be used for connecting to terminals
over long distances. The maximum specified length is 50 feet (15m),
and shielded cable must be used in order to meet the requirements
of FCC and VDE Radio Frequency Interference (RFI) regulations.
Although cable lengths of greater than 50 feet can be used with
reasonable success, cable capacitance, noise, and ground potential
difference restrict the line speed as the distances increase.
As a consequence of this, the performance of long distance communications
to a terminal using EIA-232 does not meet today's requirements
for terminal wiring. DEC423 is a superset of the RS-423-A/CCITT
V.10 standard. RS-423-A has a different grounding and signal return
path arrangement from EIA-232-D, as well as using different line
driver and receiver chips. DEC423 uses line driver and receiver
chips which have better filtering and tighter level tolerances
than those specified by RS-232-A. In addition, DEC423 devices
include transient suppressors for electrical overstress (EOS)
and electro-static discharge (ESD) protection. DEC423 devices
may also be connected with unshielded cable. The features provided
by DEC423 devices provide reliable data communication over increased
distances, typically 1000 feet (300m).
Table of Distances Between Devices
Device Type Speed: 4.8 Kbaud 9.6 Kbaud 19.2 Kbaud 38.4 Kbaud<
DEC423 device to:
DEC423 device 3000 ft 3000 ft 1000 ft 280ft
DEC423 to EIA-232-D 200 ft 200 ft 50 ft 50 ft
DEC422 to DEC422 4000 ft 4000 ft 4000 ft 4000 ft
DEC423 uses the RJ45 Modular Jack, or the Modified Modular Jack
(MMJ) connector instead of the much larger D-type connector defined
in RS-449. DEC423 is signal compatible with the EIA-232-D standard
when used for data-leads-only interconnection, ie, interconnection
between devices using the different standards is possible but
the speed and distance restrictions of EIA-232-D will still apply.
DEC423 should always be used be used in preference to EIA-232-D
for direct terminal connection over extended distances.
EIA-232-D terminals can be connected to DEC423 devices using either
an H8571-x passive adapter, or a H3105-B active adapter. The H3105-B
active terminal adapter is necessary when using an EIA-232-D terminal
with a DEC423 interface if the longer cable lengths obtainable
with DEC423 are required.
There are two types of DEC423 cable available: the H8245/6 "Building"
cable which is of twisted pair construction, and the H8240 "Office"
or flat 6-core ribbon cable. BC16E cables are pre-terminated lengths
of H8240 cable. The maximum length for DEC423 cabling has been
given, for example, 1000 feet at 19,200 Baud, and within this,
50 feet is the usually recommended maximum length of "office"
cabling, however 100 feet would probably give satisfactory results.
DEC422 also incorporates EOS/ESD protection and RS-422 compatible
drivers and receivers, thus DEC422 is ideal for use in high noise
environments. DEC422, which uses differential line drivers supports
cable lengths of up to 4000 feet (1200m) at all supported speeds.
Appendix B - EIA-232 Signal/Pin Designations
Pin Signal Description Signal Direction Common Abbreviation
1 Protective Ground to DCE & DTE GND
2 Transmitted Data to DCE TD, Tx
3 Received Data to DTE RD, Rx
4 Request To Send to DCE RTS
5 Clear To Send to DTE CTS
6 Data Set Ready to DTE DSR
7 Signal Ground/Common Return to DCE & DTE SG
8 Received Line Signal or
Data Carrier Detector to DTE DCD or CD
9 Reserved for +ve test voltage to DTE
10 Reserved for -ve test voltage to DTE
11 Unassigned
12 Secondary Received Line Signal to DTE SMI (Data Carrier) Detector
13 Secondary Clear To Send to DTE
14 Secondary Transmitted Data to DCE
15 Transmit Clock to DTE TC
16 Secondary Received Data to DTE
17 Receive Clock to DTE RC
18 Reserved
19 Secondary Request To Send to DCE
20 Data Terminal Ready to DCE DTR or TR
21 Signal Quality Detector to DTE SQ
22 Ring Indicator to DTE RI
23 Data Signal Rate Selector to DCE DSRS
24 External Transmit Clock to DCE XTC
25 Reserved. Typically used by to DCE OOS (Out Of Service).
modem manufacturers as Terminal Busy
where
DTE = Data Terminal Equipment (terminal or computer system), and
DCE = Data Communications Equipment (typically a modem).
Signal Levels used with EIA-232.
(EIA-232 is an unbalanced system with a common return).
For Data :
An EIA-232 transmitter generates a voltage of between -5 and -25
volts for a MARK (logic 1), and between +5 and +25 volts for a
SPACE (logic 0).
An EIA-232 receiver recognizes voltages of above +3 volts as spaces,
and voltages more negative than -3 volts as marks.
For Control :
Between -3 and -25 volts for a NEGATION, and between +3 and +25
volts for an ASSERTION.
EIA-423 :
EIA-423 is also an unbalanced system, but unlike EIA-232, separate
return wires are used for both transmit and receive data. With
a EIA-423 transmitter the voltage must be at least +4 volts for
a space, and -4 volts for a mark.
EIA-422 :
EIA-422 uses two separate wires for each signal, and is a balanced
system.
A mark is differentiated from a space by the polarity of one wire
with respect to the other rather than with respect to ground.
Appendix C - Terminal Server Adapters
H8584-AC
MMJ adapter. A small adapter which plugs directly in to the 8-way
MJ port of a DECserver and converts it to a 6-way MMJ. A BC16E
(crossed) cable could then be used for a terminal or printer connection.
The wiring for this adapter is straight.
H8584-AA Schematic
H8584-AB Passive Adapter for Apple Mcintosh.
This passive adapter is contained in a small moulded plastic housing
and has the following connectors:
(a) 6-way MMJ (Modified Modular Jack), female.
b) 8-pin DIN, male.
This adapter may be attached to an Apple Macintosh LOCAL (DIN)
socket, and so "convert" it to a 6-way MMJ connector
suitable for connection to a Digital terminal server via a BC16E
cable.
Wiring - straight through.
MMJ Pin Signal DIN Pin Signal
1 DTR 1 Handshake Output
2 TD+ 3 Transmit Data
3 TD- 4 Frame Ground
4 RD- 8 Receive Data +
5 RD+ 5 Receive Data
6 DSR 2 Handshake Input
6 Not Connected
7 Not Connected
H8585-AA
PC Adapter. Has a 9-way female D-type connector which plugs into
a PCs serial BC16E Cablen 8-way MJ. A BN25G (straight through)
cable would then be used to connect the 9-way communications port
of the PC to a DECserver. The wiring for the adaptor is crossed.
H8585-AA Schematic
H8585-AB
Low speed (below 9,600 baud) Modem Adapter. Has a 25-way male
D-type connector which plugs into a modem, and an 8-way MJ. A
BN25G (straight through) cable would be used to connect the modem
plus adapter to a DECserver. The wiring for this adapter is straight
through.
H8585-AB Schematic
H8585-AC
Modem Adapter (for 9,600 baud or higher). Has a 25-way male D-type
connector which plugs into a modem, and an 8-way MJ.
A BN25G cable would then be used to connect the modem plus adapter
to a DECserver. Wiring is straight through.
H8585-AC Schematic
DECserver Cable and Adapter Reference Guide.
DECserver Reference Guide
Here is a picture of, clockwise from center top, the H8585-AA,
H8585-AC, H8584-AA, and the H8585-AB:
H8585-AA etc
Appendix D - OPEN DECconnect Sample Configurations
1. 10BaseT Configuration
Sample Configuration
2. DEC423 Configuration.
Sample Configuration
Appendix E Digital's Multi-Standard 50-pin
Synchronous Interface for WAN
(Wide Area Network) Devices.
Digital use a multi-standard 50-pin, male, D-type connector for
synchronous communication
connections. This connector is attached to the following devices:-
DECNIS (Some Modules) MUXserver 90
DEMSA MicroServers MUXserver 300 series
DEMSB MicroServers DECmux 300 series
DSV11 Controller DEC WANrouter 90
DEC WANrouter 150/250 Leafbridge
Note. The DEC WANrouter 90EW, the DECbrouter 90, and the RouteAbout
family have a different type of 50-way connector (micro-Champ),
and require different adaptor cables. (see entriy BC12x-xx).
Contained within the 50-way connector are the necessary signals
for connection to the following communications standards:
EIA-422 EIA-423
X.21 V.35
V.24 (EIA-232-D) BTs KILOSTREAM
To extract the necessary signals for each of the above standards,
it is necessary to use a BC19 series
2 feet long "adapter" cable. One end of the adapter
cable is connected to the 50-pin synchronous connector,
the other to an " extender" cable, which in turn is
connected to the communications connection
Summary of adapter and extender cables for use with the standard
Synchronous Interface:
Communications Standard Adapter Cable Extender Cable
EIA-422 BC19B-02 BC55D-xx
X.21 BC19C-02* BC22Z-xx
EIA-232-D BS19D-02*** BC22F-xx
EIA-423 BC19E-02 BC55D-xx
V.35 BC19F-02 BC19L-xx
BT Kilostream BC22X-02** BC22Z-xx
* Incompatible with BT's Kilostream network.
** For use with BT's Kilostream network, and Mercury Communications
equivalent.
*** The BS23V-02 Adaptor Cable Kit is very similar to the BS19D-02,
and either of these may generally
be used for EIA-232 connections.
Multi-Standard Interface Pin Configuration
50-Way Signal Name 50-Way Signal Name
Pin Pin
1 CODE GROUND 26 V.35 CLOCK (B)
2 CODE 0 27 V.35 Rx DATA (A)
3 CODE 1 28 V.35 Rx DATA (B)
4 CODE 2 29 V.35 Tx DATA (A)
5 CODE 3 30 V.35 Tx DATA (B)
6 Tx DATA (A) 31 V.35 Rx CLOCK (A)
7 Tx DATA (B) 32 V.35 Rx CLOCK (B)
8 Tx DATA 33 DTR
9 RTS/C (A) 34 DSR (A)
10 RTS/C (B) 35 DSR (B)
11 Rx DATA (A) 36 RTS
12 Rx DATA (B) 37 DCD/I (A)
13 LOCAL LOOP 38 DCD/I (B)
14 SPEED INDICATE 39 CTS (A)
15 TEST I 40 CTS (B)
16 REM. LOOP 41 DCE GROUND
17 RI 42 TEST 1
18 Rx CLOCK (A) 43 TEST 2
19 Rx CLOCK (B) 44 DTE GROUND
20 Tx CLOCK (A) 45 DTR (A)
21 Tx CLOCK (B) 46 DTR (B)
22 CLOCK 47 CLOCK (A)
23 V.35 Tx CLOCK (A) 48 CLOCK (B)
24 V.35 TX CLOCK (B) 49 TEST 3
25 V.35 CLOCK (A) 50 SPEED
Where (A) and (B) are wires A(+ve), and B(-ve), of a twisted pair.
Synchronous Cables Summary
Cable Summary
Appendix F Ethernet Cable Parts
1. Thickwire Ethernet Cable
Ready to use pre-assembled Thickwire cables are available with
part number BNE2A-xx, and BNE2B-xx, where -xx specifies a particular
length. Pre-assembled lengths of BNE2x-xx cable may be joined
together using a Barrel Connector part number 12-19817-01. A ThickWire
segment must be properly terminated with 50-Ohm impedance terminators.
Thickwire Terminator is part number 12-19816-01. Thickwire Ethernet
cable may also be custom made using the following components:
Cable
EO-BNE2B-ME 500 metre length of low loss,
NI, coaxial cable with PVC jacket, and fitted with male N-type
ends.
Or
E0-BNE2A-ME 500 metre length of low loss,
NI, coaxial cable with TEFLON jacket, and fitted with male N-type
ends.
TEFLON jacketed cable is plenum-rated (UL-listed CMP), and PVC
jacketed cable (Tape drive for use in use in non-environmental
airspaces.
End Connectors
12-19118-00
One N type RG8.8A Plug
Testing
It is recommended that a custom made length of Thickwire cable
should be tested prior to use using a TDM (Time Domain Reflectometer),
this is particularly important for segments which are to be heavily
loaded.
2. ThinWire Ethernet Cable
Ready to use ThinWire cables with PVC jackets are available with
part number BC16M-xx . ThinWire cables may
be joined together using a Barrel Connector part number E0-H8224.
A ThinWire segment must be properly terminated with 50 Ohm impedanance
terminators. ThinWire Terminator part number is E0-H8225. To attach
a station to ThinWire Ethernet a "T" Connector ThinWire
part number E0-H8223 must be fixed directly to that station, and
the lengths of cable, or length of cable plus terminator will
be attached to the "T" connector.
ThinWire Ethernet cable may be custom made using the following
components:
Cable
H8243-A 1000 feet spool of ThinWire coaxial cable with PVC jacket.
Or
Cable H8244-A 1000 feet spool of ThinWire coaxial cable with TEFLON
jacket.
End connectors
E0-H8222 one male pin BNC connector.
Tools
The H8242 Tool Kit contains the necessary strippers and crimp
tool to attach the end connectors to the raw cable.
Appendix G - "Confusable" Cable Summary
Summary Part 1
Summary Part 2
Appendix H - Fibre Optics Notes
The fibre optic cables supplied by Digital such as the BN24B,
BN24D, or BN24E are for internal use ONLY because they do not
have a weather proofed or amoured jacket. 90% of fibre cable applications
require that the cable be run externally either in a duct or even
directly buried in the ground. It is a specialist job to define
the cable required, the possible maximum lengths and the termination
for a particular site and a particular application, so an in depth
site survey will be required. Customers who do not have access
to the necessary skills should be directed to their local Digital
office or their account manager to IBS (Intelligent Building Services)
who can provide a total installed and tested solution.
In general, the Digital recommendation for a new fibre optic installation
is for 62.5/125 micron, dual window, graded-index profile, multimode
glass-on-glass construction (EIA Class 1A). Digital is optimising
its multimode fibre products for 62.5/125 fibre.
Connectors
Types of fibre-optic connectors in current use:-
ST - Bayonet
This type of connector has a "push-twist" fastening
action. It virtually replaced the older SMA-type which has a screw-on
fastening. The ST provides a higher reliability and a better connection
than the SMA.
ST - Push-pull
The push-pull construction provides easy insertion and high repeatability.
SC
This connector is physically smaller than the ST-type, has rectangular
cross-section, and has a push-pull fixing action. There is both
a simplex and a duplex version.
Digital is using SC connectors in certain products because of
the smaller physical size and also industry demand. The SC connector
is specified in TIA/EIA 568-A. The duplex SC socket is considerably
smaller than the widely used MIC socket.
MIC
The FDDI MIC (Media Interface Connector) is a duplex connector.
The MIC is keyed, and is field programmable for the appropriate
type of FDDI connection.
FC/PC
Digital chose the FC/PC connector for SM (Single Mode) fibre applications.
One of the key selection factors was that FC-PC is physically
different to the ST and thus customers could not inadvertently
plug SM into MM (Multi Mode) sockets. However the newest physical
media dependant options (PMDs), for example the DEFXS-BA, use
ST connectors for SMF.
Additional Note For FDDI
FDDI modules which utilise Multimode Fibre (MMF) use both pairs
of ST or SC connectors and also Media Interface Connectors (MIC).
Modules utilizing Single Mode Fibre (SMF) use FC-PC connectors.
Conductors
MMF modules use 62.5/125 micron fibre. SMF modules use 8-10/125
micron fibre.
The maximum possible cable length between nodes for MMF is 2 km.
The maximum possible cable length between nodes for SMF is 40
km.
FDDI Device Connector Types
The following is list of FDDI device connector types was contributed
by Mike Collins of the Networks Business Unit @REO.
FDDI Devices for EISA
DEFEA-AA, MMF; SAS MIC
DEFEA-DA, MMF, MMF; DAS MIC, MIC
DEFEA-UA, UTP; SAS RJ45
FDDI Devices for PCI
DEFPA-UA, UTP; SAS RJ45
DEFPA-MA, UTP; DAS Pair of RJ45
DEFPA-AA, MMF; SAS Dual SC
DEFPA-DA, MMF, MMF; DAS Pair of Dual SC
FDDI Devices for TurboChannel
DEFTA-FA, MMF; SAS ST (pair of)
DEFTA-AA, MMF; SAS ST (pair of)
DEFTA-DA, MMF, MMF; DAS ST (pair of)
DEFTA-UA, UTP; SAS RJ45
DEFZA-AA, MMF; SAS ST (pair of)
DEFZA-CA, Co-ax or STP; SAS BNC, or, 9-way D-type (switchable)
FDDI Modules for Futurebus+
DEFAA-AA, MMF; SAS MIC
EFAA-DA, MMF, MMF; DAS MIC, MIC
FDDI Devices for Q-bus
EFQA-SF/SA, 2xMMF; SAS MIC
EFQA-DF/DA, MMF; DAS MIC
FDDI Devices for XMI
EMFA-AA, MMF; SAS MIC
EMFA-AB, MMF; SAS MIC
DECconcentrator 500 Modules
EFCN-MB/MH, MMF, MMF MIC + MIC
EFCN-CA/CF, SMF, MMF FC-PC + MIC
EFCN-DA/DF, MMF, SMF MIC + FC-PC
EFCN-EA/EF, SMF, SMF FC-PC + FC-PC
EFCN-LA/LF, 4 x MMF 4 x ST pairs
EFCN-NA/NF, 4 x MMF 4 x MIC
EFCN-HA/HF, 6 x MMF 6 x MIC
EFCN-FA/FF, (2 x MMF) + (2 x SMF)(2 x MIC) + (2 x FC-PC)
EFCN-TA/TF, 6 x Copper Co-ax 6 x BNC
EFCN-SA/SF, 6 X Copper STP, 6 x 9-way D-type
DECconcentrator 900
DEF6M-MA MMF 6 x MIC
DEF6U-MA UTP 6 x RJ45
DEFHM-MX MMF 12 x SC pairs
DEFHM-MM MMF 12 x SC pairs + 2 x MIC
DEFHU-MX UTP 12 x RJ45
DEFHU-MU UTP 14 x RJ45
DEFHU-MM UTP + MMF 12 x RJ45 + 2 x MIC
DEFHU-MS UTP + SMF 12 x RJ45 + 2 x SC
DECbridge 500 series
EFEB-AD MMF; SAS MIC
EFEB-AT SMF; SAS FC-PC
EFEB-DB MMF, MMF; DAS MIC, MIC
EFEB-DN SMF, MMF; DAS FC-PC, MIC
EFEB-DQ MMF, SMF; DAS MIC, FC-PC
EFEB-DT SMF, SMF; DAS FC-PC, FC-PC
DECbridge 600 series
EFEB-TB MMF; SAS MIC
EFEB-TT SMF; SAS FC-PC
EFEB-LB MMF, MMF; DAS MIC, MIC
EFEB-LN SMF, MMF; DAS FC-PC, MIC
EFEB-LQ MMF, SMF; DAS MIC, FC-PC
EFEB-LT SMF, SMF; DAS FC-PC, FC-PC
MOD PMD (Physical Media Dependent) FDDI Modules for use
in DECconncentrator 900, DEChubONE MX, and GIGAswitch/FDDI
DEFXM-AA MMF MIC
DEFXS-AA SMF FC-PC
DEFXS-BA SMF ST
DEFXU-AA/BA UTP RJ45
DEFXM-SC MMF Dual SC
DECswitch 900EF
DEFBA-MA MMF; DAS MIC, MIC
Appendix I - DSSI Connections
There are two types of DSSI connectors :
- PS (Pin Socket or Pedestal) style,
BA400 series enclosures, including the R400X and B400X expansion
enclosures.
BA200 series enclosures, including the R215F expansion pedestal
for housing up to 3 Integrated Storage Elements or ISEs.
R23RF (BA23 type enclosure for housing up to two Removable Storage
Elements or RSEs).
BA23 and BA123 enclosures fitted with KFQSA adapters.
- MR (Midrange) style,
VAX 6000, 7000, 9000, 10000 bulkheads, DSSI Storage Array Cabinets,
Tabletop TF85.
There are three types of inter-cabinet cables :
- BC21M-xx Two PS connectors.
- BC21Q-xx Two MR connectors.
- BC22Q-xx One PS, one MR connector.
There are two types of inter-cabinet Cable Kits :
- CK-SFx00-LM contains BC21Q-09 MR/MR cable.
- CK-SFx00-LP contains BC22Q-09 MR/PS cable.
Cable Kit Part Numbers
CK-SF100-LP contains BC22Q-09 MR/PS cable, plus DSSI terminator.
CK-SF100-LM contains BC21Q-09 MR/MR cable, plus DSSI terminator.
CK-SF100-L3 contains BC21Q-25 MR/MR cable, plus DSSI terminator.
CK-SF100-L4 contains BC22Q-25 MR/PS cable, plus DSSI terminator.
CK-SF100-L5 contains BC21Q-16 MR/MR cable, plus DSSI terminator.
CK-SF100-L6 contains BC22Q-16 MR/PS cable, plus DSSI terminator.
CK-SF200-LP contains BC22Q-09 MR/PS cable, plus internal BC21R-5L cable.
CK-SF200-LM contains BC21Q-09 MR/MR cable, plus internal BC21R-5L cable.
CK-SF200-L3 contains BC21Q-25 MR/MR cable, plus internal BC21R-5L cable.
CK-SF200-L4 contains BC22Q-25 MR/PS cable, plus internal BC21R-5L cable.
CK-SF200-L5 contains BC21Q-16 MR/MR cable, plus internal BC21R-5L cable.
CK-SF200-L6 contains BC22Q-16 MR/PS cable, plus internal BC21R-5L cable.
CK-SF200-L7 contains BC21Q-50 MR/MR cable, plus internal BC21R-5L cable.
CK-SF200-L8 contains BC22Q-50 MR/PS cable, plus internal BC21R-5L cable.
Inter Cabinet Cable Part Numbers
BC21M-03, -09, -16, -25 (feet).
BC21Q-3F (3.5 feet), -06, -09, -16, -25, -50 (feet).
BC22Q-09, -16, -25 (feet).
BC29R-06, -09, -16, -45 (feet)
BC29S-06, -09, -16, -30, -45, -60 (feet)
BC29T-03, -06 (feet)
BC29U-02 (feet)
BC29V-01, -06, -16 (feet)
List of DSSI Device Connector Types
DSSI Device Connector Type
SF1xx Pedestals MR
SF2xx Cabinets MR
DECarray 300 Cabinets MR
SF400 Cabinets MR
TF8x -TA Tabletop enclosures MR
R400X Expansion Enlosure PS
SF12 Expansion Enclosure PS
VAX/DEC 6000/7000 MR
VAX/DEC 4000 PS
KFDDA-AA VAX 4000-100A/DSSI Adapter PS
KFDDA-AF VAX 4000-100A/DSSI Adapter PS
KFDDA-BA VAX 4000-100A/DSSI Adapter PS
KFDDB-Ax VAX 4000-500A,600A,700A/DSSI Adapter PS
KFESA-AA EISA/DSSI Adapter MR
KFMSA-BA XMI/DSSI Adapter MR
KFMSB-AA XMI/DSSI Adapter MR
KFPSA-AA PCI/DSSI Adapter MR
KFQSA-xx Q-bus/DSSI Adapter PS
HSD30-xx DSSI/SCSI Controller MR
HSD05-xx DSSI/SCSI Adapter MR
Appendix J SCSI Device Connector Types
There are four types of SCSI connector in current use
- 50-way Low-Density (or CENTRONICS Style, or CHAMP). This is
the largest of the connector types. This is the type of connector
used on most older SCSI expansion cabinets.
- 68-way High-density (or HONDA).
- 50-way High-density (or HONDA).
- 68-way Very High Density (0.8mm pitch)
List of connector types used with system/expansion boxes
ApplicationDEC433W 50-way high-density female (HD 50 F)
BA346 50 pin high density female (HD50 (F)
BA350 50-way high-density female (HD 50 F)
BA353 50-way high-density female (HD 50 F)
BA356 68-way high-density female (HD 68F)
BA356, 8 bit I/O module 50 pin high-density female (HD50F)
BA362/364 * 68 pin high density female (HD68F)
AlphaSatation 200/250/255/400 50-way high-density female (HD 50F)
AlphaStation 500/600 68 pin high density female (HD 68F)
AlphaServer 400/1000/2000/2100 50-way high density female (HD 50F)
DEC 2000-300/500 50-way high-density female (HD 50 F)
(Adaptec 1740 EISA
controller, PB2HA-SA).
DEC 3000-300 50-way high-density female (HD 50 F)
DEC 3000-400/500/600/ Low-density (LD)
700/800/900 (for on-board
SCSI controller).
DEC 4000-6x0/7x0 Low-density (LD)
(Preferred SCSI cable: BN21R).
DECstation 3100 68-way high-density male (HD 68 M)
DECstation/system 50-way high-density female (HD 50 F)
5000 model 20,25,33,
50,125,133,240,260
DECsystem 5100 Low-density (LD)
Digital 2100 Server 50-way high-density female (HD 50 F)
A500 MP systems.
Infoserver 100/150 68-way high-density male (HD 68 M)
Infoserver 1000 50-way high-density female (HD 50 F)
Infotower 1000 Low-density (LD)
MicroVAX 3100 Low-density (LD)
model 10,20,10e,20e
model 30,40,80,90
MD30C scanner Low-density (LD)
RRD45 Tabletop Low-density (LD)
RWZ21 Low-density (LD)
SZ03 Low-density (LD)
SZ12 Low-density (LD)
SZ16 Low-density (LD)
SZ18 Low-density (LD)
SZ100/SZ106/SZ107 Low-density (LD)
TL810 High-density (HD68 F)
TL820 Low-density (LD)
TKZ08/TKZ09 Low-density (LD)
TZK10/TZK11 Low-density (LD)
TZK60 Low-density (LD)
TLZ04/TLZ06 Low-density (for tabletop drive) (LD)
TLZ07/TLZ09 Low-density (for tabletop drive) (LD)
TLZ6L/TLZ7L Low-density (LD)
TSZ05/TSZ07 Low-density (LD)
TZ87/88N-TA Low-density (LD)
Tabletop drive.
TZ877/TZ887-A* Low-density (LD)
Tape drive for use in SW500/
800 cabinet.
With this option, a converter
cable is supplied to make it
HD50 compatible. Use of the
BN21H is recommended in SW500/800
for the first drive, and a BC19J-03
for connecting the second tape drive
to the first drive.
VAX 4000-100 series Low-density (LD)
VAXstation 3100 68-way high-density male (HD 68 M)
model 30,40,38,48,76
VAXstation 4000 Low-density (LD)
model VLC/60/90
*Note. A straight entry cable must be used to connect into the BA362/364.
List of connector types used with Options
DWZZA-AA Low-density, and also (S/E port: LD)
68-way high-density (Differential port: HD 68)
DWZZB-AA High density (S/E port: HD 68
(Differential port: HD68)
FR-PCTAR-AA No external connector.
1 channel SCSI raid controller
(MyleX) (EISA bus).
FR-PCTAR-AB 50-pin high-density female (HD 50 F)
1 channel SCSI raid controller
(Mylex) (EISA bus).
FR-PCTAZ-AE 50-pin high-density female (HD 50 F)
FR-PCTAZ-CB 50-pin high-density female (HD 50 F)
FR-PCTAZ-DA 50-pin high-density female (HD 50 F)
HSZ10-AX 68-pin high-density female (HD 68 F)
HSZ40 68-pin for host port. (HD68 F)
KZDDA-AA Low-density (LD)
KZESC-xx 50-pin high density (HD50 F)
KZMSA 50-pin high-density female (HD 50 F)
KZPAA 50-pin high density (HD50 F)
KZPDA 68-pin high density female (HD68F)
KZPSA-BB 68-pin high-density female (HD 68 F)
KZPSC-xx 68-pin very-high-density female (VHD 68 F)
KZTSA-AA 68-pin high-density female (HD 68 F)
KZQSA-xx Low-density (LD)
PB2HA-SA 50-pin high-density female (HD 50 F)
PC4XR-CC Low-density (LD)
PCTAZ-AB 50-pin high-density female (HD 50 F)
PCTAZ-AD Low-density (LD)
PCTAZ-CD Low-density (LD)
PMAZ/PMAZB 50-pin high-density female (HD 50 F)
PMAZC 50-pin high-density female (HD 50 F)
Appendix K Summary of SCSI Cables
SCSI Cable Summary
LD = Low Density, or Centronics type connector. HD=
High Density, or Honda connector. VHD = Very High Density
(0.8 mm pitch)
Notes.
In general, all SCSI cables with a "BC" designation
are not wired to Fast SCSI specifications, whereas virtually all
cables made with a "BN" designation are wired to Fast
SCSI specifications, i.e.they have the correct impedance and internal
wiring which is suitable for use with the demanding Fast SCSI.
Appendix L SCSI and DSSI Terminators and Tri-Link
Adaptors - Summary
SCSI Terminators
H8574-A Single-ended, 8-bit SCSI bus Terminator with 50-pin,
male, low-density connector.
Example usage: attached to a BN21V-02 adapter cable to terminate
a single-ended SCSI bus at an end position controller, this would
facilitate the removal of that controller without interrupting
the bus.
12-29635-01 Single-ended, 8-bit SCSI bus Terminator with
68-pin, female, high-density connector.
Example usage: supplied with early workstations and InfoServer
150 for bus termination.
H879 -AA FWD (Fast Wide Differential) SCSI bus Terminator
with 68-pin, high-density, male connector.
Example usage: attached to an H885 -AA Tri-link Connector Block
to terminate a FWD SCSI at an end position controller, this would
facilitate removal of that controller without interrupting the
bus.
12-37004-04
50-pin, active single-ended terminator.
SCSI Connector Block
H885 -AA FWD SCSI Tri-link Connector Block with three 68-pin,
high-density connectors, one one side one male, on the other side
two female. A typical configuration would be:
Male To a Controller
Female 1 To an H879-AA Terminator
Female 2 To a BN21K cable
DSSI Terminator
12-31281-01 DSSI bus Terminator with 50-pin, female MR
type connector. Typical usage: with a 12-39921-02 DSSI Tri-link
Adapter attached to a DSSI controller/adapter to facilitate the
removal of that adapter without interrupting the DSSI bus.
DSSI Connector Block
12-39921-02 DSSI Tri-link Connector Block which is supplied
attached to the DSSI port of DSSI controllers/adapters such as
the HSD05, HSD10, HSD30, HS1CP. The adapter presents two 50-pin,
male, MR connectors, to which would be attached a DSSI cable and
a 12-31281-01 DSSI terminator, or two DSSI cables.
|