It was a bad conrtoller board, it was replaced and is now running. The new
card went out to the Drives located a configuration files and loaded it, all
on it's own. Pretty nice. We also added a redundant dual controller. ***
Hint here, if your using write back cache, and your adding a new HSZ50
controller, let the batteries fully charge before you "set failover",
otherwise it will disable all of your RAID sets that use write back cache.
***
Received on Fri Jun 11 1999 - 20:27:55 NZST