HI All , 
        Thanks to all the people who wrote and phoned ! . 
        I finally got a couple of engineers from Digital over
        who basically wanted to have a good long play with
        the HSZ22 & SWCC  . Basically the deal is : 
        To upgrade to 2 controllers , you have to insert the first
        controller , and backup its configuration to the PC . 
        You then remove the first controller and put the second
        one in the top slot. You then restore the config from the PC .
        Then you can put the original controller in the bottom slot . 
        The fact of the second controller being greyed out on the
        SWCC tcp/ip conection is correct .
        
        What we found out was that if you failover a controller
        with the PC SWCC GUI , you have to physically pop it 
        out and in to recover it , doing a restart from the GUI
        doesn't work . Also if you refresh the GUI after 
        replacing the controller , it doesn't show the controllers
        as going back to active/active . This is a bug , You have
        to close the GUI down and re-open/connect it to get the 
        correct display . 
        You can connect a second kzpba adapter to the port
        H1 if you want and select target 1 for naming some 
        other disks and use that for load sharing . 
Thanking you ,
Gary  Menna			     E-Mail   g.menna_at_isu.usyd.edu.au
Information Technology Services      Phone    +61 2 9351-6360
University of Sydney      (G05)	     Fax      +61 2 9351-7711	   	
        *-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*-*
        *					*