OpenVMS Debugger Manual


Previous Contents Index

10.4.5 Deactivating, Activating, and Canceling Breakpoints

After a breakpoint is set, you can deactivate, activate, or delete it.

Deactivating a breakpoint causes the debugger to ignore the breakpoint during program execution. However, the debugger keeps the breakpoint listed in the breakpoint view so that you can activate it at a later time, for example, when you rerun the program (see Section 9.3). Note the following points:

Activating a breakpoint causes it to take effect during program execution:

When you cancel a breakpoint, it is no longer listed in the breakpoint view so that later you cannot activate it from that list. You have to reset the breakpoint as explained in Section 10.4.1 and Section 10.4.2. Note the following points:

10.4.6 Setting a Conditional Breakpoint

The debugger suspends execution of the program at a conditional breakpoint only when a specified expression is evaluated as true. The debugger evaluates the conditional expression when program execution reaches the breakpoint and ignores the breakpoint if the expression is not true.

The following procedure sets a conditional breakpoint, whether or not a breakpoint was previously set at that location:

  1. Display the source line on which you want to set the conditional breakpoint (see Section 10.1).
  2. Do one of the following:
  3. Enter a relational expression in the Condition: field of the dialog box. The expression must be valid in the source language. For example, a[3] == 0 is a valid relational expression in the C language.
  4. Click on OK. The conditional breakpoint is now set. The debugger indicates that a breakpoint is conditional by changing the shape of the breakpoint's button from a square to a diamond.

Figure 10-6 Setting a Conditional Breakpoint


The following procedure modifies a conditional breakpoint; that is, it can be used either to change the location or condition associated with an existing conditional breakpoint, or to change an unqualified breakpoint into a conditional breakpoint:

  1. Choose Views... from the Options menu on the main window or optional views window. When the Views dialog box appears, click on Breakpoint View to display the breakpoint view.
  2. From the breakpoint view, do one of the following:
  3. Follow steps 3 and 4 of the previous procedure, as appropriate.

10.4.7 Setting an Action Breakpoint

When a program reaches an action breakpoint, the debugger suspends execution of the program and executes a specified list of commands.

To set an action breakpoint, whether or not a breakpoint was previously set at that location:

  1. Display the source line on which you want to set the action breakpoint (see Section 10.1).
  2. Do one of the following:
  3. Enter one or more debugger commands in the Action: field of the dialog box. For example: DEPOSIT x[j] = 3; STEP; EXAMINE a
  4. Click on OK. The action breakpoint is now set (see Figure 10-7.)

Figure 10-7 Setting an Action Breakpoint


The following procedure modifies an action breakpoint; that is, it can be used either to change the location or command associated with an existing action breakpoint, or to change an unqualified breakpoint into an action breakpoint:

  1. Choose Views... from the Options menu on the main window or optional views window, then click on Breakpoint View when the Views dialog box appears.
  2. From the breakpoint view, do one of the following:
  3. Follow steps 3 and 4 of the previous procedure, as appropriate.

10.5 Examining and Manipulating Variables

This section explains how to:

See Section 10.6, which also applies to all operations on variables.

10.5.1 Selecting Variable Names from Windows

Use the following techniques to select variable names from windows for the operations described in the sections that follow (see Section 10.5.2 for examples).

When selecting names, follow the syntax of the source programming language:

Select character strings from windows as follows:

10.5.2 Displaying the Current Value of a Variable

To display the current value of a variable:

  1. Find and select the variable name in a window as explained in Section 10.5.1.
  2. Click on the EX button in the push button view. The debugger displays the variable and its current value in the command view. The debugger displays the value of a variable in the current scope, which might not be the same as the source location you were intending.

Figure 10-8, Figure 10-9, and Figure 10-10 show how to display the value of an integer variable, array aggregate, and array element, respectively.

Figure 10-8 Displaying the Value of an Integer Variable


Figure 10-9 Displaying the Value of an Array Aggregate


Figure 10-10 Displaying the Value of an Array Element


To display the current value in a different type or radix, use the following alternative method:

  1. Find and select the variable name in a window as explained in Section 10.5.1.
  2. Choose Examine... in the Commands menu in the main window. The Examine dialog box appears with the name selected in the Variable/Expression field.
  3. Choose the default, int, long, quad, short, or char* item from the Typecast menu within the dialog box.
  4. Choose the default, hex, octal, decimal, or binary item from the Output Radix menu within the dialog box.
  5. Click on OK.

The value, altered to your specification, appears in the command view.

Figure 10-11 shows that the variable j has been typecast as long.

Figure 10-11 Typecasting the Value of a Variable


10.5.3 Changing the Current Value of a Variable

To change the current value of a variable:

The new value, altered to your specification, appears in the command view and is assigned to the variable.

Figure 10-12 shows a new value for the variable safe.

Figure 10-12 Changing the Value of a Variable


10.5.4 Monitoring a Variable

When you monitor a variable, the debugger displays the value in the monitor view and checks and updates the displayed value whenever the debugger regains control from your program (for example, after a step or at a breakpoint).

Note

You can monitor only a variable, including an aggregate such as an array or structure (record). You cannot monitor a composite expression or memory address.

To monitor a variable (see Figure 10-13):

  1. Find and select the variable name in a window as explained in Section 10.5.1.
  2. Click on the MON button in the push button view. The debugger:

You can typecast the output value when monitoring variables by choosing the Typecast item in the Monitor menu.

You can change the output radix when monitoring variables as follows:

To remove a monitored element from the monitor view, choose Remove from the Monitor menu.

Figure 10-13 Monitoring a Variable


10.5.4.1 Monitoring an Aggregate (Array or Structure) Variable

If you select the name of an aggregate variable, such as an array or structure (record) and click on the MON button, the debugger displays the word Aggregate in the Value/Deposit column of the monitor view. To display the values of all elements (components) of an aggregate variable, double click on the variable name in the Monitor Expression column (or choose Expand in the Monitor menu). The displayed element names are indented relative to the parent name (see Figure 10-14). If an element is also an aggregate, you can double click on its name to display its elements, and so on.

Figure 10-14 Expanded Aggregate Variable (Array) in Monitor View


To collapse an expanded display so that only the aggregate parent name is shown in the monitor view, double click on the name in the Monitor Expression column (or choose Collapse from the Monitor menu).

If you have selected a component of an aggregate variable, and the component expression is itself a variable, the debugger monitors the component that was active when you made the selection. For example, if you select the array component arr[i] and the current value of i is 9 , the debugger monitors arr[9] even if the value of i subsequently changes to 10 .

10.5.4.2 Monitoring a Pointer (Access) Variable

If you select the name of a pointer (access) variable and click on the MON button, the debugger displays the address of the referenced object in the
Value/Deposit column of the monitor view (see the top entry in Figure 10-15).

To monitor the value of the referenced object (to dereference the pointer variable), double click on the pointer name in the Monitor Expression column. This adds an entry for the referenced object in the monitor view, indented under the pointer entry (see the bottom entry in Figure 10-15). If a referenced object is an aggregate, you can double click on its name to display its elements, and so on.

Figure 10-15 Pointer Variable and Referenced Object in Monitor View


10.5.5 Watching a Variable

Whenever the program changes the value of a watched variable, the debugger suspends execution and displays the old and new values in the command view.

To watch a variable (also known as setting a watchpoint on a variable):

Figure 10-16 Watched Variable in Monitor View


To deactivate a watchpoint, clear its Watched button in the monitor view (by clicking on the button) or choose Toggle Watchpoint in the Monitor menu. To activate a watchpoint, fill in its Watched button or choose Toggle Watchpoint in the Monitor menu.

Section 10.6.1 explains static and nonstatic (automatic) variables and how to access them. The debugger deactivates a nonstatic watchpoint when execution moves out of (returns from) the variable's defining routine. When a nonstatic variable is no longer active, its entry is dimmed in the monitor view and its Watched button is cleared.

The debugger does not automatically reactivate nonstatic watchpoints if execution later returns to the variable's defining routine. You must reactivate nonstatic watchpoints explicitly.

10.5.6 Changing the Value of a Monitored Scalar Variable

To change the value of a scalar (nonaggregate) variable, such as an integer or Boolean type (see Figure 10-17):

  1. Monitor the variable as explained in Section 10.5.4.
  2. Click on the variable's value in the Value/Deposit column of the monitor view. A small dialog box is displayed over that value, which you can now edit.
  3. Enter the new value in the dialog box.
  4. Click on the check mark (OK) in the dialog box. The dialog box is removed and replaced by the new value, indicating that the variable now has that value. The debugger notifies you if you try to enter a value that is incompatible with the variable's type, range, and so on.

Figure 10-17 Changing the Value of a Monitored Scalar Variable


To cancel a text entry and dismiss the dialog box, click on X (Cancel).

You can change the value of only one component of an aggregate variable (such as an array or structure) at a time. To change the value of an aggregate-variable component (see Figure 10-18):

  1. Display the value of the component as explained in Section 10.5.4.1.
  2. Click on the variable's value in the Value/Deposit column of the monitor view. A small dialog box is displayed over that value, which you can now edit.
  3. Enter the new value in the dialog box.
  4. Click on the check mark (OK) in the dialog box. The dialog box is removed and replaced by the new value, indicating that the variable now has that value. The debugger notifies you if you try to enter a value that is incompatible with the variable's type, range, and so on.

Figure 10-18 Changing the Value of a Component of an Aggregate Variable


10.6 Accessing Program Variables

This section provides some general information about accessing program variables while debugging.

If your program was optimized during compilation, you might not have access to certain variables while debugging. When you compile a program for debugging, it is best to disable optimization, if possible (see Section 1.2.1).

Before you check on the value of a variable, always execute the program beyond the point where the variable is declared and initialized. The value contained in any uninitialized variable should be considered invalid.

10.6.1 Accessing Static and Nonstatic (Automatic) Variables

Note

The generic term nonstatic variable is used here to denote what is called an automatic variable in some languages.

A static variable is associated with the same memory address throughout execution of the program. You can always access a static variable.

A nonstatic variable is allocated on the stack or in a register and has a value only when its defining routine or block is active (on the call stack). Therefore, you can access a nonstatic variable only when program execution is paused within the scope of its defining routine or block (which includes any routine called by the defining routine).

A common technique for accessing a nonstatic variable is first to set a breakpoint on the defining routine and then to execute the program to the breakpoint.

Whenever the execution of your program makes a nonstatic variable inaccessible, the debugger notifies you as follows:

10.6.2 Setting the Current Scope Relative to the Call Stack

While debugging a routine in your program, you can set the current scope to a calling routine (a routine down the stack from the routine in which execution is currently paused). This enables you to:

The Call Stack menu on the main window lists the names of the routines (and, under certain conditions, the images and modules) of your program that are currently active on the stack, up to the maximum number of lines that can be displayed on your screen (see Figure 10-19). The numbers on the left side of the menu indicate the level of each routine on the stack relative to level 0, which denotes the routine in which execution is paused.

To set the current scope to a particular routine on the stack, choose the routine's name from the Call Stack menu (see Figure 10-19). This causes the following to occur:

Figure 10-19 Current Scope Set to a Calling Routine


When you set the scope to a calling routine, the current-location pointer (which is cleared) marks the source line to which execution will return in that routine. Depending on the source language and coding style used, this might be the line that contains the call statement or some subsequent line.


Previous Next Contents Index