POLYCENTER Software Installation Utility Developer's
Guide
MODULE
The MODULE statement adds or replaces one or more modules in a command,
help, macro, object, or text library file.
Syntax
MODULE file TYPE type MODULE
(module_name[,...]) [ [NO] GENERATION generation
] [ [NO] GLOBALS ] [ LIBRARY library ] [ [NO]
SELECTIVE SEARCH ] ;
Parameters
file
Indicates the relative file specification of the file that contains the
modules.
TYPE type
The library type. Table 7-7 lists the keywords you can specify with
this parameter.
Table 7-7 Library Types for Module Statement
Keyword |
Library Type |
Default Library File |
Command
|
Command definition library
|
[SYSLIB]DCLTABLES.EXE
|
Help
|
Help library
|
[SYSHLP]HELPLIB.HLB
|
Macro
|
Macro library
|
[SYSLIB]STARLET.MLB
|
Object
|
Object library
|
[SYSLIB]STARLET.OLB
|
Text
|
Text library
|
[SYSLIB]STARLETSD.TLB
|
MODULE module_name
The list of module names you are specifying.
Options
[NO] GENERATION generation
Indicates that the file has an explicit generation number. Specify the
number as an unsigned integer in the range of 0 through 4294967295. See
the Description section for the meaning of this value. By default, the
file does not have an explicit generation number (no generation), which
is equivalent to 0.
[NO] GLOBALS
Indicates whether the global symbol names of the modules you are
inserting into an object library are included in the global symbol
table. You can use this option with object libraries only. By default,
the global symbols of the module are inserted into the global symbol
table.
LIBRARY library
Indicates the relative file specification of the library. The file you
specify must be a library of the type you specified with the TYPE
parameter.
[NO] SELECTIVE SEARCH
Indicates whether the input modules being inserted into the library are
available for selective searches by the linker (by default, they are
not). You cannot use this option with the command and help libraries.
For more information about selective searches, see the HP OpenVMS Linker Utility Manual.
Description
The MODULE statement adds or replaces one or more modules in a command
library file, or a single module in a help, macro, object, or text
library file. The MODULE statement adds the module name to the product
database. You do not need to use a REGISTER MODULE statement in
addition to a MODULE statement to register the module name.
Use the MODULE parameter to specify the name of the module object. For
a help, macro, object, or text library, the name specified with the
MODULE parameter should be the same as the name of the module itself.
The module object has assembly lifetime, and its scope is the same as
the library.
A module inserted into a command, help, object, text, or macro library
can conflict with another module having the same name that is already
resident in the library. Two types of module conflict can occur:
- An interproduct module conflict occurs when two or
more products provide a module with the same name.
- An intraproduct module conflict occurs when two or
more patch or partial kits for a product update the same module.
The utility resolves a module conflict by comparing the generation
numbers of the modules involved.
A generation number is an optional attribute you supply on either the
MODULE or REGISTER MODULE statement using the GENERATION option. A
generation number can be any integer in the range of 0 to 4294967295.
If you do not specify a generation number, its default value is 0.
Table 7-8 Resolving Module Conflict with Generation Numbers
If the generation numbers |
Then |
Are different
|
The module with the largest non-zero number is selected.
|
Are the same and are not zero
|
The module from the kit replaces the previously installed module.
|
Are zero
|
Unresolvable file conflict, an error is reported to the user. Note that
for
V6.1-V6.2 a module with an explicit generation number
of 0 might be selected over a module with a default value of 0.
|
Generation information is not used for intraproduct conflict detection
when a product is upgraded. In this case, all modules from the old
version are deleted, and new modules from the kit are placed on the
target disk. However, generation information is used during an upgrade
for interproduct conflict detection when any modules from the product
conflict with modules from another product.
See Also FILE
REGISTER MODULE
Examples
#1 |
module [SYSUPD]CDD.CLD type COMMAND module CDD ;
|
The statement in this example creates the command module CDD in the
default command library [SYSLIB]DCLTABLES.EXE using the file
[SYSUPD]CDD.CLD.
#2 |
module [SYSUPD]HELP.HLP type HELP module HELP ;
|
The statement in this example creates the help module in the default
help library [SYSHLP]HELPLIB.HLB using the file [SYSUPD]HELP.HLP.
#3 |
module [SYSUPD]SPI$CONNECT.MAR type MACRO
library [SYSLIB]LIB.MLB module SPI$CONNECT ;
|
The statement in this example creates the macro module SPI$CONNECT in
the macro library [SYSLIB]LIB.MLB using the file
[SYSUPD]SPI$CONNECT.MAR.
#4 |
module [SYSUPD]COBRTL.OBJ type OBJECT module COBRTL;
|
The statement in this example creates the object module COBRTL in the
default object library [SYSLIB]STARLET.OLB using the file
[SYSUPD]COBRTL.OBJ.
#5 |
module [SYSUPD]PROTOTYPE_BOOK.TXT type TEXT
library [SYSLIB]LPS$FONT_METRICS.TLB module PROTOTYPE_BOOK;
|
The statement in this example creates the text module PROTOTYPE_BOOK in
the text library [SYSLIB]LPS$FONT_METRICS.TLB using the file
[SYSUPD]PROTOTYPE_BOOK.TXT.
NETWORK OBJECT
The NETWORK OBJECT statement uses a command procedure to create a
DECnet network object.
Syntax
NETWORK OBJECT name WITH (parameters,...) ;
Parameters
name
Indicates the name of the network object. The network object name is
passed to the command procedure as P1.
WITH (parameters,...)
Indicates the list of parameters that are passed to the command
procedure that creates the network object. Each parameter must be a
single quoted string that specifies P2 through P5, in order. See the
Description section for the meaning of the parameters.
Description
The NETWORK OBJECT statement uses a command procedure
(SYS$UPDATE:PCSI$CREATE_NETWORK_OBJECT.COM) to create network objects.
The command procedure determines whether DECnet Phase IV or
DECnet--Plus is running on the system. If Phase IV is being used, the
command procedure runs the Network Control Program (NCP) utility to
create the network object. Otherwise, it runs the Network Control
Language (NCL) utility.
In the case of DECnet--Plus, the network object created during the
product installation will exist only in memory. It is recommended that
DECnet--Plus objects be supplied in the form of an NCL script with a
FILE statement and activated with a product startup procedure.
The utility passes the following parameters to the command procedure:
- P1 specifies the name of the network object (using the
name parameter).
- P2 specifies the object number (for DECnet Phase IV systems only).
- P3 specifies the user name associated with the object. If you
specify a user name, it must already exist.
Note
The password of the specified user account is changed when the network
object is created by PCSI$CREATE_NETWORK_OBJECT.COM. The new password
is system generated, and can be viewed with the NCP command SHOW
OBJECT.
|
- P4 specifies optional parameters to use with the NCP command DEFINE
OBJECT for DECnet Phase IV objects.
- P5 specifies optional parameters to use with the NCL command CREATE
SESSION CONTROL APPLICATION for DECnet--Plus objects.
When you remove a product that created network objects, the POLYCENTER
Software Installation utility uses a command procedure
(SYS$UPDATE:PCSI$DELETE_NETWORK_OBJECT.COM) to delete network objects
associated with your product.
|