Thanks to Roland Loykens for his quick response.
The real problem was in the firmware on the 90L+'s. They were at 4.7 and
they needed to be at 5.5 to work with anything over 4.0b of Tru64 UNIX. The
bad thing is that the 90L+'s require a chip change to up the firmware.
Compaq field service was able to obtain one, which we were able to prove
that was the problem, but we need 15 more.
If anyone knows where we can get the part DSRVG-RK I would appreciate it.
Thanks
Howard
Original message:
Has anyone had any issues using a DECserver 90L+ to connect to printers with
5.0A? I have configured the LAT port using:
latcp -A -p 631 -H TEST -R PORT
I can see the port when I do latcp -d -p, but when I try to print it doesn't
work. My print cap seems alright:
lp|lp0|0|la75h:\
:af=/usr/adm/lpacct:\
:br#4800:\
:ct=LAT:\
:fc:#0177777:\
:fs#03:\
:if=/usr/lbin/la75of:\
:lf=/usr/adm/lp0err:\
:lp=/dev/lat/631:\
:mx#0:\
:of=/usr/lbin/la75of:\
:pl#66:\
:pw#80:\
:sd=/usr/spool/lpd0:\
:sb:\
:xc#0177777:\
:xf=/usr/lbin/xf:\
:xs#044000:
Howard
arnoldh_at_celerent.com
Received on Mon Dec 04 2000 - 14:03:09 NZDT